Description:
Pressure filter series HPF 60-450 have a working
pressure up to 315 bar. Pressure peaks can be absorbed
with a sufficient safety margin. The HPF-filters are
flanged to the mounting-surface.
The filter element consists of star-shaped, pleated filter
material, which is supported on the inside by a perforated
core tube and is bonded to the end caps with a high-
quality adhesive. The flow direction is from outside to
inside. Filter elements are available down to 5 µm
(c)
.
Finer filtration is available upon request.
For cleaning the stainless steel mesh element (see
special leaflets 21070-4 and 39448-4) or changing the
filter element, remove the filter bowl and take out the
element. The mesh elements are not guaranteed to
maintain 100% performance after cleaning.
Eaton filter elements are known for high intrinsic stability
and an excellent filtration capability, a high dirt-retaining
capacity and a long service life.
Eaton filter can be used for petroleum-based fluids, HW
emulsions, water glycols, most synthetic fluids and
lubrication fluids. Consult factory for specific fluid
applications.
Eaton filter elements are available up to a pressure
resistance of p 160 bar and a rupture strength of p 250
bar.
The internal valves are integrated into the centering pivot
for the filter element. After reaching the opening pressure
the by-pass valve causes that an unfiltered partial flow
passes the filter.
With the reverse valve a protection of the filter element is
given when having a reverse flow inside the filter. The
reverse flow will not be filtered.
Type index:
Complete filter: (ordering example)
pressure filter, manifold mounted
nominal size: 60, 90, 150, 170, 240, 360, 450
80G, 40G, 25G stainless steel wire mesh
25VG, 16VG, 10VG, 6VG, 3VG microglass
filter element collapse rating:
p 160 bar (rupture strength p 250 bar)
filter element specification:
for HFC applications, see sheet-no. 31601
filter housing specification:
for HFC applications, see sheet-no. 31605
with by-pass valve p 3,5 bar
with by-pass valve p 7,0 bar
reversing valve, Q 70,06 l/min (HPF 60-150)
Q 211,008 l/min (HPF 170-450)
clogging indicator or clogging sensor:
visual, see sheet-no. 1606
visual, see sheet-no. 1606
visual-electric, see sheet-no. 1615
electronic, see sheet-no. 1619
To add an indicator/sensor to your filter, use the corresponding
indicator data sheet to find the indicator details and add them to
the filter assembly model code.
Filter element: (ordering example)
filter element according to company standard
nominal size: 60, 90, 150, 170, 240, 360, 450
see type index-complete filter