Typical Section
Typical PCG5V model with internally drained pilot piston
February 1996 GB-2329A
PCGV-6/8, 10 Series; PCG5V-6/8, 20 Series
Basic Characteristics
Max. operating pressure 350 bar . . . . . .
(5000 psi)
Max. flow rates:
PCG(5)V-6 150 L/min (40 USgpm). . . .
PCG(5)V-8 300 L/min (80 USgpm). . . .
Mounting surfaces to ISO 5781:
PCG(5)V-6 AG-06-2-A. . . . . . . . . . . . . . .
PCG(5)V-8 AH-08-2-A. . . . . . . . . . . . . . .
General Description
These pilot operated check valves
operate as a direct check valve but can
also be opened by pilot pressure, on the
control piston, to permit free reverse
flow. The amount of pilot pressure
required to open the valve is stated as a
ratio of the pressure above the check to
the pilot pressure.
Two basic types of valve are available
relative to the piloting method. The
PCGV model is the traditional type
requiring an external remote pilot valve
to control the admission and release of
pressure to the pilot piston. The other,
the PCG5V model, has a fitted
solenoid-operated pilot valve that
obviates a separate mounting and can
include manual override(s) for local
emergency control. The PCG5V type
can take its hydraulic pilot supply from
the load pressure in the adjacent
cylinder under control or from a remote
source. Where cylinder pressure is to be
used and where even the minimal
internal leakage through the closed pilot
valve would cause an unacceptable
amount of cylinder “creep”, a Vickers
poppet-type pilot valve can be
substituted. This pilot would be a model
DG3VP-3-103A (see catalog 642); ask
your Vickers representative for advice.
All PCG(5)V valves are available with or
without an integral decompression
feature.
Features and Benefits
Less power wastage from low
pressure drops.
Smooth steady lowering of heavy
weights in conjunction with flow
control valves aided by use of
externally drained models.
Zero-leakage design to prevent
actuator “creep” from check valve
leakage.
Smooth release of stored energy by
using models with decompression
poppets.
Extra-fast response from solenoid
piloted models using actuator-
supplied pilot pressure instead of
remote external source.
International standard mountings
permit fitment on many existing
installations.
Reduced installed cost and space
results from higher power/weight
ratios.
Operation of both types of valve is
portrayed in the “Functional Symbols”
section, whilst the following sectional
illustration shows the construction of the
solenoid controlled type. The remote
piloted type operates and can be used
in the same ways as the previous 4CG
models described in the Vickers
“Industrial Hydraulics Manual”. The
solenoid pilot directional control valve
option is basically the same as the
single solenoid directional valve shown
in the same manual.
Pilot Operated Check Valves
Vickers
®
Check Valves
Pilot operated check valve with
externally drained pilot piston,
PCGV-**(D)-1-10 model
Solenoid controlled pilot operated check
valve with internally drained pilot piston,
PCG5V-**(D), 11 and 20 series
Solenoid controlled pilot operated check
valve with externally drained pilot piston,
PCG5V-**(D)-1, 11 and 20 series
XA B
XA B Y
XYA B
BA
PT
BA
XYA B
BA
PT
BA
Features in brackets ( ) may be omitted if not required. All other features must be
specified.
Basic Models (Without Integral Solenoid Pilot Valve)
(F3-)
Fluid compatibility
Blank = Antiwear hydraulic oil
(class L-HM), invert emulsion
(class L-HFB) or water glycol
(class L-HFC)
F3 = As above or phosphate ester
(class L-HFD)
Mounting surface ISO 5781
6 = Code AG-06-2-A
8 = Code AH-08-2-A
Cracking pressure
A = 2 bar (29 psi)
C = 5 bar (73 psi)
F = 10 bar (145 psi)
Decompression feature
Omit if not required
External drain option
1 = Externally drained pilot piston
Omit for internally drained pilot piston
Manual override options
Override option in solenoid end only.
Blank = Plain manual override
H = Water-resistant override,
DC solenoid only
Z = No override
Solenoid identity method
V = Solenoid A at port A end of pilot
valve; solenoid B at B end of
pilot valve (German practice).
Omit for solenoid identity to USA ANSI
B93.9 standard, i.e. energize solenoid
A for P to A; solenoid B for P to B.
PCGV- * -1*
1 2 3 4 11
1
2
3
4
(-1)
5
Models With Integral Solenoid Pilot Valve
(F3-) PCG5V
1 2 3 4 9
(D)(-1) -(V)M- *** (L)- * -2*
5 7 8 10 11
Solenoid connection type
U = ISO 4400 (DIN 43650) on coil
FW =
1
/
2
NPT thread conduit box
FTW =
1
/
2
NPT thread conduit box
and terminal strip
FJ = M20 thread conduit box
FTJ = M20 thread conduit box and
terminal strip
Other connection types as shown in
catalog 2015 (DG4V-3/3S) may be made
available depending on quantities.
Female connector to be supplied by user.
Indicator lights
Option for solenoid connection types
F(T)W and F(T)J
L = Lights fitted
Omit if lights not required
For U type coil, use plug with integral
light, see 7 pages on.
Coil rating
A = 110V AC
B = 110V AC 50 Hz/120V AC 60 Hz
C = 220V AC 50 Hz
D= 220V AC 50 Hz/240V AC 60 Hz
G = 12V DC
H = 24V DC
For 60 Hz or dual frequency.
Design number
10 series for PCGV models
20 series for PCG5V models
Subject to change. Installation
dimensions unaltered for design
numbers 10-19 and 20-29 respectively.
5
6
8
9
7
* - (D)
-** - -E-*
6
5
10
11
2
Functional Symbols
Examples:
Pilot operated check valve with
internally drained pilot piston,
PCGV-**(D)-10 model
Model Code
5
3
4
10
10
10
3
Operating Data
Typical with petroleum oil at 21 cSt (102 SUS) and at 50C (122F).
Maximum pressures:
Ports A, B and X
Port Y :
PCGV, 10 series
PCG5V, 20 series
Normally drained directly to the reservoir. For fast closure of valves
under low load pressure conditions use the external drain option
(“1” at model code ). For PCGV models apply pressure to port Y to
retract the pilot piston.
350 bar (5000 psi)
350 bar (5000 psi)
100 bar (1500 psi)
PCG5V, 20 series valves are designed to satisfy the needs of most
applications. Consult your Vickers representative about an alternative
model if:
a) Valves are required to remain pressurized for long periods without
frequent switching, and/or
b) Back pressure on port Y is required to rise above 100 bar (1500 psi)
Maximum flow rates:
PCG(5)V-6
PCG(5)V-8
150 L/min (40 USgpm)
300 L/min (80 USgpm)
Cracking pressures See Model Code
Pilot piston area ratios
Without decompression feature:
All models
With decompression feature (D at model code ):
PCG(5)V-6 models
PCG(5)V-8 models
3,5:1
33,8:1
52,6:1
Pilot pressure See page 5
Pressure drops See next page
Electrical Data for PCG5V Models
Coil voltages See Model Code
Permissible voltage fluctuation:
Maximum
Minimum
See Temperature Limits, page 5
90% of rated voltage, see Model Code
Relative duty factor Continuous, ED = 100%
Types of protection:
ISO 4400 coils with plug fitted correctly
Conduit box
Coil winding
Lead wires (coils type F**)
Coil encapsulation
IEC144, class IP65
IEC144, class IP65
Class H
Class H
Class F
Power consumption for coils listed in Model Code :
AC coils:
Types A, C at 50 Hz
Types B, D at 50 Hz
Types B, D at 60 Hz
DC coils:
G
H
Initial Holding
VA (rms) VA (rms)
225 39
265 49
260 48
30W
30W
1st half cycle; solenoid armature fully retracted.
PCG(5)V-6 models
PCG(5)V-8 models
Port B to A, piloted open Curve 1. . . . .
Port A to B, no pilot pressure:
PCG(5)V-*A models Curve 2. . . . . . . . .
PCG(5)V-*C models Curve 3. . . . . . . . .
PCG(5)V-*F models Curve 4. . . . . . . . .
0
50 100 150
010203040
L/min
USgpm
0
100
200
300
psi
5
10
15
20
bar
Flow rate
1
2
3
4
Pressure drop
0 50 100 150 200 250 300
0
0
20 40 60 80
L/min
USgpm
5
10
15
20
25
30
bar
100
200
300
400
psi
Flow rate
1
4
2
3
Pressure drop
4
Performance Characteristics
Typical with petroleum oil at
21 cSt (102 SUS) and at 50C (122F)
unless stated otherwise.
Pressure Drops
1
For internally drained pilot piston models, no symbol at model code :
Pilot pressure P
X
=
P
B
P
A
Area ratio
+ P
A
+C
For externally drained pilot piston models, 1 at model code :
Pilot pressure P
X
=
P
B
Area ratio
+ 0,85 P
Y
+C
5
5
10
5
Pilot Pressure
The pilot pressure required to open the
check valve or decompression poppet is
stated as a ratio of the pressure on the
check (port B) to the pilot pressure. To
determine the required pilot pressure the
following formulae should be used.
These are valid for pressures calculated
in either bar or psi, using the appropriate
C factor.
Hydraulic Fluids
All valves can be used with:
Antiwear hydraulic oils (class L-HM)
Invert emulsions (class L-HFB)
Water glycol (class L-HFC)
Phosphate ester (class L-HFD), adding
F3- prefix at model code .
The extreme viscosity range is from
500 to 13 cSt (2270 to 70 SUS) but the
recommended range is 54 to 13 cSt
(245 to 70 SUS).
For further information about fluids see
catalog 920.
Where:
P
X
= Pressure at pilot port X
P
B
= Pressure at free flow outlet port B
P
A
= Pressure at free flow inlet port A
P
Y
= Back pressure at drain port Y
C = Varies according to cracking
pressure, see table.
Temperature Limits
Minimum ambient: 20C (4F)
Maximum ambient:
For PCGV valves: 70C (158F)
For PCG5V valves with coils listed in
model code and at 110% of rated
voltage:
Coil type and
frequency
Max. ambient
temperature
Dual frequency coils
at 50 Hz
at 60 Hz
65C (149F)
65C (149F)
Single frequency coils
at 50 Hz
65C (149F)
DC coils 70C (158F)
Fluid temperatures (all models)
Petroleum
oil
Water-
containing
Min. 20C
(4F)
+10C
(+50F)
Max.* +70C
(+158F)
+54C
(+129F)
* To obtain optimum service life from both
fluid and hydraulic system, 65C (150F)
normally is the maximum temperature
except for water-containing fluids.
Model
type
“C” factor
bar
psi
PCG(5)V-6A
PCG(5)V-6C
PCG(5)V-6F
0,6
1,5
4,0
9
22
58
PCG(5)V-8A
PCG(5)V-8C
PCG(5)V-8F
0,6
1,5
3,0
9
22
44
For synthetic fluids consult fluid
manufacturer or Vickers
representative where limits are
outside those of petroleum oil.
Whatever the actual temperature
range, ensure that viscosities stay
within the limits specified in the
Hydraulic Fluids section.
Contamination Control
Requirements
Recommendations on contamination
control methods and the selection of
products to control fluid condition are
included in Vickers publication 9132 or
561, Vickers Guide to Systemic
Contamination Control. The book also
includes information on the Vickers
concept of ProActive Maintenance.
The following recommendations are
based on ISO cleanliness levels at
2 mm, 5 mm and 15 mm. For products in
this catalog the recommended levels
are:
Up to 210 bar (3050 psi) 20/18/15. . . . .
Above 210 bar (3050 psi) 20/18/15. . . .
Installation Dimensions in mm (inches)
6
PCGV Model
3rd angle
projection
For port functions see Mounting Surfaces, page 8
PCGV-**(D)-1 models only:
Alternative drain port G
1
/
4
(
1
/
4
BSPF).
Remove plug to make connection.
B
C
A
D
E
G
F
K
L
J
Ø17 (0.67 dia)
Mounting surface
seals supplied
Ø11 (0.43 dia)
HPort A Port B
Model A B C D E F G H
PCGV-6*(D)-10
PCGV-6*(D)-1-10
PCGV-8*(D)-10
PCGV-8*(D)-1-10
38 (1.5)
66 (2.6)
38 (1.5)
66 (2.6)
82 (3.2)
82 (3.2)
98 (3.9)
98 (3.9)
24 (1.0)
24 (1.0)
23 (0.9)
23 (0.9)
12 (0.47)
12 (0.47)
13 (0.5)
13 (0.5)
55 (2.2)
55 (2.2)
74 (2.9)
74 (2.9)
62 (2.5)
62 (2.5)
78 (3.1)
78 (3.1)
89 (3.5)
89 (3.5)
103 (4.1)
103 (4.1)
10 (0.4)
10 (0.4)
11 (0.45)
11 (0.45)
PCG5V-6*(D)---20
PCG5V-6*(D)-1---20
PCG5V-8*(D)---20
PCG5V-8*(D)-1---20
82 (3.2)
82 (3.2)
98 (3.9)
98 (3.9)
12 (0.47)
12 (0.47)
13 (0.5)
13 (0.5)
55 (2.2)
55 (2.2)
74 (2.9)
74 (2.9)
62 (2.5)
62 (2.5)
78 (3.1)
78 (3.1)
89 (3.5)
89 (3.5)
103 (4.1)
103 (4.1)
10 (0.4)
10 (0.4)
11 (0.45)
11 (0.45)
Model J K L M N
PCGV-6*(D)-10
PCGV-6*(D)-1-10
PCGV-8*(D)-10
PCGV-8*(D)-1-10
33 (1.3)
35 (1.4)
56 (2.2)
56 (2.2)
60 (2.4)
60 (2.4)
68 (2.7)
68 (2.7)
72 (2.8)
72 (2.8)
PCG5V-6*(D)---20
PCG5V-6*(D)-1---20
PCG5V-8*(D)---20
PCG5V-8*(D)-1---20
56 (2.2)
56 (2.2)
60 (2.4)
60 (2.4)
68 (2.7)
68 (2.7)
72 (2.8)
72 (2.8)
165 (6.5)
165 (6.5)
168 (6.6)
168 (6.6)
86 (3.4)
114 (4.5)
86 (3.4)
114 (4.5)
8
With Type F** Coil Connection
(F(T)J or F(T)W at model code )
8
The solenoid identification is printed on the nameplate of the pilot valve. Identification options
are described under Model Code .
For ANSI/NFPA method (no symbol at model code ) solenoid identity is: Sol. A.
For German method (V in model code ) solenoid identity is: Sol. B.
Ref. model code :
Codes FJ and FW: 2 lead wires for each solenoid, approx.150,00 (6.0) long. M3 terminals
provided for customer connection.
Codes FTJ and FTW: lead wires connected into terminal strip suitable for M3 terminals on
customer connection.
AC solenoid: 45,0 (1.8)
DC solenoid: 61,0 (2.4)
For coil removal:
With DC solenoid: 156 (6.14)
With AC solenoid: 146 (5.75)
For manual override type H:
15,0 (0.6)
For solenoid identification see
M
13,0 (0.5) for
plug removal
NB
M
NB
AC solenoid: 45,0 (1.8)
DC solenoid: 61,0 (2.4)
For coil removal:
With DC solenoid: 156 (6.14)
With AC solenoid: 146 (5.75)
For manual override type H:
15,0 (0.6)
For solenoid identification see
Conduit entry both ends, see
Model Code . Closure plug
fitted to one end.
Ground (earth) connection:
Ø0,4 (0.16 dia) self-tapping
screw
8
May vary according to plug source.
Plug not supplied; order separately if
required. For available plug types see
section Electrical Plugs and
Connectors.
8
7
7
7
7
PCG5V Models
With Type U Coil Connection
(U at model code )
XCGVM-6-10R Subplate
Tolerance on bolt and pin locations
"0,1 mm (0.004)
See Mounting Surfaces section above
for port usage
C (min.)
D (min.)
F (min.)
Q (min.)
N (min.)
E
J
P
H
K
L
M
T
S
R
U (min.)
Ø M10 x 16,0 (0.63)
min. depth full thread
Ø 4,8 (0.19 dia)
Ø 7,5 (0.3 dia) x 6,0
(0.24) deep min.
A
B
X
Y
Ø 4,8 (0.19 dia)
116,0 (4.5)
104,0 (4.1)
80,0 (3.15)
12,0 (0.5)
26,9 (1.06)
43,0 (1.7)
21,0 (0.83)
20,0 (0.8)
150,0
(6.0)
88,0
(3.5)
24,0 (0.95)
69,0
(2.7)
126,0
(5.0)
56,0
(2.2)
18,9 (0.75)
Port A
Port B
Tapped G1
(1 BSPF)
x 19,0 (0.75) depth
full thread in
underside
R28,0 (1.1 rad.)
Ø 7,5 (0.3 dia) x 6,0 (0.24)
deep, for valve
locating pin
4 holes, Ø 11,0 (0.43 dia)
through, Ø 17,5 (0.69 dia)
spotface
Port Y
Port X
Tapped G
1
/
4
(
1
/
4
BSPF) x
12,0 (0.5) depth
full thread in
underside
Y
X
A
B
4 holes tapped M10
x 16,0 (0.63) min.
depth full thread
8
Mounting Surfaces, Based on
ISO 5781, Codes:
AG-06-2-A
AH-08-2-A
When a subplate is not used a raised
machined pad must be provided for
mounting. The pad must be flat within
0,01mm/100 mm (0.001/10) and
smooth within 0,8 mm (32 min).
Dimensional tolerances are "0,2 mm
(0.008) except where indicated.
Port functions
A = Free flow inlet and controlled
reverse flow outlet
B = Free flow outlet and controlled
reverse flow inlet
X = Pilot control port
Y = External drain port
Size
A dia. B dia. C D E F H J K
06 14,7
(0.58)
14,7
(0.58)
61,0
(2.4)
9,0
(0.4)
42,9
(1.69)
9,0
(0.4)
35,7
(1.4)
31,8
(1.25)
21,4
(0.84)
08 23,4
(0.92)
23,4
(0.92)
78,0
(3.1)
8,8
(0.35)
60,3
(2.37)
8,8
(0.35)
49,2
(1.94)
44,5
(1.75)
39,7
(1.56)
Size L M N P Q R S T U
06 21,4
(0.84)
7,1
(0.28)
10,0
(0.4)
66,7
(2.62)
10,0
(0.4)
58,7
(2.3)
33,3
(1.3)
7,9
(0.31)
87,0
(3.4)
08 20,6
(0.81)
11,1
(0.44)
10,8
(0.43)
79,4
(3.125)
10,8
(0.43)
73,0
(2.87)
39,7
(1.56)
6,4
(0.25)
101,0
(4.0)
Installation Data
9
Mounting Attitude
Unrestricted.
Subplates
For PCG(5)V-6 valves see type
XCVGM-6-10R, on previous page.
For PCG(5)V-8 valves consult your
Vickers representative.
Mass (approx.)
Mounting Bolts/Torques
For PCG(5)V-6 valves:
bolt kit BKPCGV-6.
For PCG(5)V-8 valves:
bolt kit BKPCGV-8.
Bolts should be torqued to 59-73 Nm
(44-53 lbf ft), with threads lubricated.
PCG(5)V-6
kg (lb)
PCG(5)V-8
kg (lb)
PCGV with internal drain
PCGV with external drain
3,2 (7)
4,0 (8.8)
4,9 (10.8)
5,9 (13)
PCG5V with internal drain
AC voltage models
DC voltage models
5,7 (12.6)
5,9 (13)
7,3 (16.1)
7,5 (16.5)
PCG5V with external drain
AC voltage models
DC voltage models
6,5 (14.3)
6,7 (14.8)
8,3 (18.3)
8,5 (18.7)
Pilot piston drain.
XCGVM-6-10R subplate: 3,0 kg (6.6 lb)
Electrical Plugs and
Connectors
Plugs for ISO 4400 (DIN 43650) Type
Coil Connection
For valves with type U coils (see model
code).
The cable entry on these plugs can be
repositioned at 90 intervals by
reassembly of the contact holder relative
to the plug housing. The cable entry is
Pg 11 for cable Ø 6-10 mm (0.24-0.40
dia).
Order plugs separately by part number.
Voltage
Part number
Gray
(Sol. A)
Black
(Sol. B)
Without indicator light
710776 710775
With indicator light
12-24V
100-125V
200-240V
977467
977469
977471
977466
977468
977470
For valves with type F** coils, see model code location
8
For FTJ or FTW at model code For FTJL or FTWL at model code +8 8 9
1.For DC coils the +ve lead(s) must be
connected to the terminal(s) marked +.
When using 3-wire incoming leads to
double solenoid valves (i.e. common
neutral) the inner pair of terminals must
be linked.
2. For correct light indication of energized
solenoid ensure that solenoid leads are
correctly connected: light terminals are
common with each outer pair of solenoid
terminals according to the side with +
mark.
Terminal strip (part number 890345)
clips to cover and can be field-fitted
M3 x 0,5-6H screws (part
number 186006) 2 each end
Connections to solenoid A
(or B, according to model type)
Connections to solenoid B
(or A, according to model type)
Rubber gasket
Conduit box cover and nameplate
complete with sealing gasket and
4 screws
Anti-rotation tab ensures
correct orientation of cover
to junction box
28,50
(1.12)
30,00
(1.18)
Lights
2 lenses in cover
4 terminal screws M3 x 0,5-6H
(part number 02-113355)
10
Terminal Strip and Lights
Ordering Procedure
Valves, subplates and bolt kits should
be ordered by full model code
designation.