24
58,5 (2.3)
DGMC2-2-AB-*W-BA-*W-1*
DGMC2-2-AT-*W-BT-*W-1*
Dimensions shown in mm (inches)
34,0
(1.34)
12,7
(0.5)
29,0
(1.14)
25,0 (0.99)
50,0 (1.97)
265,0 (10.43) max.
58,5 (2.3)
17,5
(0.69)
36,8
(1.45)
35,0
(1.38)
4 holes thru
5,5 (0.21 dia.)
A
B
P
T
Hex locknut
12,7 (1/2”)
across flats
Adjuster screw
4,0 (5/32”)
across flats
hex. socket
15,0
(0.59)
30,0
(1.18)
3,0 (0.12)
3,0 (0.12 dia.)
94,5 (3.72 max.)
25,0
(0.99)
square
20,0
(0.78)
26,0
(1.02)
119,0 (4.68)
W adjuster (Shown)
To adjust valve setting. loosen
locknut and turn adjuster screw
clockwise to increase pressure,
counterclockwise to decrease
pressure. Re-tighten locknut
after completing adjustment.
H adjuster
To adjust valve setting. loosen locknut
and turn knob clockwise to increase
pressure, counterclockwise to
decrease pressure. Re-tighten
locknut after completing adjustment.
K adjuster
Key must be inserted and turned to
allow valve setting to be adjusted.
Turn knob clockwise to increase
pressure, counterclockwise to
decrease pressure. When key is
removed, adjustment mechanism
can be freely turned without
changing valve setting.