Screw-in Cartridge Valves
Proportional Flow Control Valves
EFV1-10
2
3
EATON Vickers Screw-in Cartridge Valves V-VLPO-MS001-E September 2003
2
EFV1-10
*
-0
Proportional flow control
valve, normally open,
spool type
1
2
3
2
3
1
Functional Symbol
Profile View
Description
The EFV1-10
*
-0
**
is a
normally open, unidirection-
al, uncompensated, spool
type, two way, proportional
flow control, screw-in
cartridge valve.
Operation
The valve is controlled by
current supplied to the coil.
At zero current, the valve
is fully open from port 2 to
port 3. At 1500 to 1600 mA
(12V coil) the valve is fully
closed. Port 1 is used for
pressure balancing the spool
and armature and must be
blocked in all cases.
The maximum intended
pressure drop is 300 PSID.
At pressure drops above
300 PSID, almost no
increase in flow is obtained.
The intended flow direction
is from port 2 to port 3.
Operation of the valve with
flow from port 3 to port 2
will produce flow vs current
and flow vs pressure drop
curves that are significantly
different from those
obtained with flow from
port 2 to port 3.
Since the spool and arma-
ture are pressure balanced,
the operating pressure
does not affect the operat-
ing characteristics of the
valve. The operating point
of the valve is determined
only by current, pressure
drop and temperature.
RATINGS AND SPECIFICATIONS
Performance data is typical with DTE 24 hydraulic fluid at 120°F
Typical application pressure 210 bar (3000 psi)
Cartridge endurance rating 1 million cycles
Cartridge fatigue pressure rating (NFPA/T2.6.1 R2-2000) 210 bar (3000 psi)
Cartridge burst pressure rating (NFPA/T2.6.1 R2-2000) 751 bar (10,900 psi)
Rated maximum flow at 160 PSID Flow rating “A” 15.1 L/min (4 USgpm)
Flow rating “B” 30.2 L/min (8 USgpm)
Flow rating “C” 37.9 L/min (10 USgpm)
Hysteresis 1 USgpm with 400Hz PWM driver
Leakage (fully closed) 197 cm
3
/min (12 in
3
/min) at 3000 PSID
Ambient operating temperature -30° to 90°C (-22° to 194°F)
Maximum oil temperature 120°C (248°F)
Maximum internal coil temperature 200°C (392°F)
Nominal supply voltage 12/24 V
Current to fully close valve 1500 - 1600 mA (12V coil), 750 - 800 mA (24V coil)
Recommended PWM frequency 200 - 400 Hz
Coil resistance at 20°C (68°F) 4.7 (12V), 19.0 (24V)
Mass Cartridge only 0,37 kg (0.82 lb)
Cartridge with coil and end nut 0,73 kg (1.62 lb)
Fluid All general purpose hydraulic oils such as:
MIL-H-5606, SAE 10, SAE 20, DTE 24, etc.
Filtration Cleanliness code 18/16/13
Cavity C-10-3
Seal kit 9900225-000 (Buna-N)
9900226-000 (Viton
®
)
Viton is a registered trademark of E.I. DuPont
Note
Port 1 is unused and must
be plugged.
EATON Vickers Screw-in Cartridge Valves V-VLPO-MS001-E September 2003
3
Performance
Curves
EFV1-10
*
-0
Cartridge Only
Max. Flow vs Pressure Drop
Flow rating "A" (Valve fully open)
Flow - USgpm
0
2
4
20
30
40
50
60
10
0
6
8
10
12
14
16
Flow - L/min
0 50 100 150 200 250 300
Pressure Drop - PSID
0 6.9 20.7
Pressure Drop - bar
10.3 13.8 17.23.4
Flow - USgpm
0
2
4
20
30
40
50
60
10
0
6
8
10
12
14
16
Flow - L/min
0 50 100 150 200 250 300
Pressure Drop - PSID
0 6.9 20.7
Pressure Drop - bar
10.3 13.8 17.23.4
Flow - USgpm
0
2
4
20
30
40
50
60
10
0
6
8
10
12
14
16
Flow - L/min
0 50 100 150 200 250 300
Pressure Drop - PSID
0 6.9 20.7
Pressure Drop - bar
10.3 13.8 17.23.4
Max. Flow vs Pressure Drop
Flow rating "B" (Valve fully open)
Max. Flow vs Pressure Drop
Flow rating "C" (Valve fully open)
Note
To determine operating
characteristics for the flow
rating selected, at a specific
differential pressure, first
determine maximum flow
from upper curve at the dif-
ferential pressure value.
This will be the “100%
flow” flow on the lower
curve.
Parameters: 400 Hz PWM
Flow vs. Current
0
25
50
75
100
0 200 400 600 800 1000 1200 1400 1600
Flow %
Current - mA
EATON Vickers Screw-in Cartridge Valves V-VLPO-MS001-E September 2003
4
EFV1 – 10
*
– 0
* *
* ***
*****
E
**
– 00
1
2 4 5 6 73 8 109
Model Code EFV1-10-O
Function
EFV1
- Electro Proportional
Flow Control Valve
Size
10
- 10 Size
Seals
N
- Buna-N
V - Viton
®
Logic
0
- Normally Open
4
3
2
1
Flow Rating
A
- 4 USgpm @ 160 PSID
B - 8 USgpm @ 160 PSID
C - 10 USgpm @ 160 PSID
Bleed Screw and
Manual Override
0 - No core tube special
features
B - Bleed screw
P - Bleed screw and
push-pin type manual
override
S - Screw-in type manual
override
6
5
Material Port
Code Code*
Description Part Number Port 1 Plug
0 000 No manifold block ––
A 03B Aluminum, Light Duty 02-173358 4995036-003
3/8 BSPP
06T Aluminum, Light Duty SAE 6 566162 125-6T
02G Aluminum, 1/4 BSPP 876705 4995036-002
03G Aluminum, 3/8 BSPP 876714 4995036-003
06H Aluminum, SAE 6 876704 125-6T
08H Aluminum, SAE 8 876711 125-8T
S 02G Steel, 1/4 BSPP 02-175127 4995036-002
03G Steel, 3/8 BSPP 02-175128 4995036-003
06T Steel, SAE 6 02-175124 125-6T
08T Steel, SAE 8 02-175125 125-8T
Note: Both the manifold and port plug are required.
87
Coil Model Code*
See page C-10.
* These model digits will not be stamped
on the valve.
9
Special Features
00
- None
(Only required when valve
has special features, omitted
if 00.)
10
Note: EFV1-10 with DIN-43650 connector
shown.
Note - S type manual override shown
Dimensions
mm (inch)
Torque cartridge in housing
S - 68-75 Nm
(50-55 ft. lbs)
A - 47-54 Nm
(35-40 ft. lbs)
Note: Port 1 is unused and must be plugged.
EATON Vickers Screw-in Cartridge Valves V-VLPO-MS001-E September 2003
5
EFV1-10
*
-C
Proportional flow control
valve, normally closed,
spool type
1
2
3
2
3
1
Functional Symbol
Profile View
Description
The EFV1-10
*
-C
**
is a
normally closed, unidirec-
tional, uncompensated,
spool type, two way, pro-
portional flow control,
screw-in cartridge valve.
Operation
The valve is controlled by
current supplied to the coil.
At zero current, the valve is
fully closed from port 3 to
port 2. At 1500 mA (12V
coil) the valve is considered
fully open. This is the maxi-
mum intended current level
for use in applications.
Port 1 is used for pressure
balancing the spool and
armature and must be
blocked in all cases.
The maximum intended
pressure drop is 300 PSID.
At pressure drops above
300 PSID, almost no
increase in flow is obtained.
The intended flow direction
is from port 3 to port 2.
Operation of the valve with
flow from port 2 to port 3
will produce flow vs current
and flow vs pressure drop
curves that are significantly
different from those
obtained with flow from
port 3 to port 2.
Since the spool and arma-
ture are pressure balanced,
the operating pressure does
not affect the operating
characteristics of the valve.
The operating point of the
valve is determined only by
current, pressure drop and
temperature.
RATINGS AND SPECIFICATIONS
Performance data is typical with DTE 24 hydraulic fluid at 120°F
Typical application pressure 210 bar (3000 psi)
Cartridge endurance rating 1 million cycles
Cartridge fatigue pressure rating (NFPA/T2.6.1 R2-2000) 210 bar (3000 psi)
Cartridge burst pressure rating (NFPA/T2.6.1 R2-2000) 751 bar (10,900 psi)
Rated maximum flow at 160 PSID Flow rating A 15.1 L/min (4 USgpm)
Flow rating B 30.2 L/min (8 USgpm)
Flow rating C 37.9 L/min (10 USgpm)
Hysteresis 1 USgpm with 400Hz PWM driver
Leakage (fully closed) 197 cm
3
/min (12 in
3
/min) at 3000 PSID
Ambient operating temperature -30° to 90°C (-22° to 194°F)
Maximum oil temperature 120°C (248°F)
Maximum internal coil temperature 200°C (392°F)
Nominal supply voltage 12/24 V
Current to fully close valve 1500 - 1600 mA (12V coil), 750 - 800 mA (24V coil)
Recommended dither frequency 200 - 400 Hz
Coil resistance at 20°C (68°F) 4.7 (12V), 19.0 (24V)
Mass Cartridge only 0,37 kg (0.82 lb)
Cartridge with coil and end nut 0,73 kg (1.62 lb)
Fluid All general purpose hydraulic oils such as:
MIL-H-5606, SAE 10, SAE 20, DTE 24, etc.
Filtration Cleanliness code 18/16/13
Cavity C-10-3
Seal kit 9900225-000 (Buna-N)
9900226-000 (Viton
®
)
Viton is a registered trademark of E.I. DuPont
Note
Port 1 is unused and must
be plugged.
EATON Vickers Screw-in Cartridge Valves V-VLPO-MS001-E September 2003
6
Performance
Curves
EFV1-10
*
-C
Cartridge Only
Max. Flow vs Pressure Drop
Flow rating "A" (Zero Current)
Flow - USgpm
0
2
4
20
30
40
50
60
10
0
6
8
10
12
14
16
Flow - L/min
0 50 100 150 200 250 300
Pressure Drop - PSID
0 6.9 20.7
Pressure Drop - bar
10.3 13.8 17.23.4
Flow - USgpm
0
2
4
20
30
40
50
60
10
0
6
8
10
12
14
16
Flow - L/min
0 50 100 150 200 250 300
Pressure Drop - PSID
0 6.9 20.7
Pressure Drop - bar
10.3 13.8 17.23.4
Flow - USgpm
0
2
4
20
30
40
50
60
10
0
6
8
10
12
14
16
Flow - L/min
0 50 100 150 200 250 300
Pressure Drop - PSID
0 6.9 20.7
Pressure Drop - bar
10.3 13.8 17.23.4
Max. Flow vs Pressure Drop
Flow rating "B" (Zero Current)
Max. Flow vs Pressure Drop
Flow rating "C" (Zero Current)
Note
To determine operating
characteristics for the flow
rating selected, at a specific
differential pressure, first
determine maximum flow
from upper curve at the dif-
ferential pressure value.
This will be the 10 0%
flow on the lower curve.
Parameters: 400 Hz PWM
Flow vs. Current
0
25
50
75
100
0 200 400 600 800 1000 1200 1400 1600
Flow %
Current - mA
32,0
(1.26)
19,1 (0.75)
32,8 (1.29)
44,2 (1.74)
86,4
(3.40)
64,0
(2.52)
47,2
(1.86)
2
3
1
108,7
(4.28)
Note - S type manual override shown
EATON Vickers Screw-in Cartridge Valves V-VLPO-MS001-E September 2003
7
Model Code EFV1-10-C
Dimensions
mm (inch)
Torque cartridge in housing
S - 68-75 Nm
(50-55 ft. lbs)
A - 47-54 Nm
(35-40 ft. lbs)
EFV1 10
*
C
* *
* ***
*****
E
**
00
1
2 3 4 5 6 7 8 109
Function
EFV1
- Electro Proportional
Flow Control Valve
Size
10
- 10 Size
Seals
N
- Buna-N
V - Viton
®
Logic
C
- Normally Closed
4
3
2
1
Flow Rating
A
- 4 USgpm @ 160 PSID
B - 8 USgpm @ 160 PSID
C - 10 USgpm @ 160 PSID
Bleed Screw and
Manual Override
0 - No core tube special
features
B - Bleed screw
P - Bleed screw and
push-pin type manual
override
S - Screw-in type manual
override
6
5
Material Port
Code Code*
Description Part Number Port 1 Plug
0 000 No manifold block ––
A 03B Aluminum, Light Duty 02-173358 4995036-003
3/8 BSPP
06T Aluminum, Light Duty SAE 6 566162 125-6T
02G Aluminum, 1/4 BSPP 876705 4995036-002
03G Aluminum, 3/8 BSPP 876714 4995036-003
06H Aluminum, SAE 6 876704 125-6T
08H Aluminum, SAE 8 876711 125-8T
S 02G Steel, 1/4 BSPP 02-175127 4995036-002
03G Steel, 3/8 BSPP 02-175128 4995036-003
06T Steel, SAE 6 02-175124 125-6T
08T Steel, SAE 8 02-175125 125-8T
Note: Both the manifold and port plug are required.
87
Coil Model Code*
See page C-10.
* These model digits will not be stamped
on the valve.
9
Special Features
00
- None
(Only required when valve
has special features, omitted
if 00.)
10
Note: Port 1 is unused and must be plugged.
Note: EFV1-10 with DIN-43650 connector
shown.
Eaton
14615 Lone Oak Road
Eden Prairie, MN 55344
USA
Tel: 952 937-9800
Fax: 952 974-7722
www.hydraulics.eaton.com
Eaton
20 Rosamond Road
Footscray
Victoria 3011
Australia
Tel: (61) 3 9319 8222
Fax: (61) 3 9318 5714
Eaton
Dr.-Reckeweg-Str. 1
D-76532 Baden-Baden
Germany
Tel: (49) 7221 682-0
Fax: (49) 7221 682-788
© 2003 Eaton Corporation
All Rights Reserved
Printed in USA
Document No. V-VLPO-MS001-E