Proportional Valves
Proportional Directional Valves with Feedback
K(B)FD/TG4V-5, 1*/2* Series
Pressures to 315 bar (4500 psi)
2 EATON Vickers
®
Proportional Valves KBFD/TG4V-5 V-VLPO-MC008-E1 April 2009
Table of Contents
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Typical Section View. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Model Code . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Spool Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Fuctional Symbols . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Operating Data
Valves with Amplifier, KBFD/TG4V-5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Valves without Amplifier, KFD/TG4V-5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
KBFD/TG4V-5 & KFD/TG4V-5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Pressures and Flow Rates . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Performance Curves
Power Capacity Envelopes, Single Solenoid Models . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Power Capacity Envelopes, Double Solenoid Models . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Flow Gain Curves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Frequency Response . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Installation Dimensions
KFDG4V-5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
KFTG4V-5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
KBFDG4V-5. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
KBFTG4V-5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Subplates and Mounting Surfaces
General Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Installation Dimensions, KDGSM-5-676805-2* (w/rear port L) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Installation Dimensions, EKDGSM-01Y-1*-R (w/side port L) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Installation Dimensions, KDGSM-5-615225-1* . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Installation Dimensions, KDGSM-5-615226-1* . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Mounting surface interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Parallel Path Flow Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Electrical Information
Block Diagram Voltage Input (M1) KBFDG4V-5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Block Diagram Current Input (M2) KBFDG4V-5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Wiring Connections Voltage Input (M1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Wiring Connections Current Input (M2) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Application Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
3EATON Vickers
®
Proportional Valves KBFD/TG4V-5 V-VLPO-MC008-E1 April 2009
Introduction
General Description
Eaton Vickers
®
K(B)FD/
TG4V proportional valves
are designed to provide
a controlled oil flow in
direct proportion to a
command signal. They are
available in two types; a
double solenoid version
that will provide reversible
flow to an actuator and
a single solenoid throttle
version that provides a
single direction of flow.
Hydrostats are available
for load compensation and
parallel flow path modules
are available that will boost
the flow capacity of single
solenoid throttle versions
to nearly twice that of the
standard valve.
Additionally, both of these
valve types can be supplied
with or without an integral
amplifier built directly onto
the valve.
KFD/TG4V-5
This version is supplied
without the integral
amplifier.
Features and Benefits
Wide range of spool and
flow rate options.
Electronic feedback LVDT
ensures accurate spool
position control.
Vibration and shock
tested.
Supported by a broad
range of amplifiers
and auxiliary function
modules.
Full CE electromagnetic
compatibility.
KBFD/TG4V-5
A range of proportional
directional and throttle
valves with integral control
electronics. Factory-set
adjustments of gain, spool
deadband compensation
and offset ensure consistent
repeatability valve-to-valve.
The only electrical inputs
required are power supply
(24V) and a voltage
command signal of
±10V
or 4-20 mA. The amplifier
is housed in a robust metal
enclosure, sealed against
ingress of water and other
fluids. Electrical connections
are via a standard 7-pin plug.
A spool position monitor
pin allows the function of
the valve to be electrically
monitored. Ramp functions,
if required, can be generated
externally.
Features and Benefits
• Factory-sealed adjust-
ments ensure valve-to-
valve reproducibility.
Installation wiring reduced
and simplified.
Standard 7-pin connector.
• Standard 24V DC supply
with wide tolerance band.
• Optional
±10V DC or 4-20
mA command signals.
• Valve with integrated
amplifier selected,
ordered, delivered and
installed as one perfor-
mance-tested package.
• Spool position monitor pin
to help with troubleshoot-
ing.
• Simple valve removal and
replacement for service
(plug & play).
• Vibration and shock tested.
• Auxiliary DIN rail mounted
electronic function mod-
ules available. Full CE
electromagnetic compat-
ibility.
• IP65 & IP67 valve environ-
mental protection rating.
• Optional valve enable
function.
Typical Section View
KBFD/TG4V-5-*PE7, 1* Design
4 EATON Vickers
®
Proportional Valves KBFD/TG4V-5 V-VLPO-MC008-E1 April 2009
Model Codes
321
76
4 9
8
5 1716
1110 1312
14 15
1918 2120
1
Valve Type
K Proportional valve
2
Integral Amplifier
B Integral amplifier “B”
series. Omit for models
without integral amplifier
3
Feedback Arrangement
F Spool position
4
Control Type
D Directional valve
T Throttle valve
5
Mounting
G Subplate mounted
6
Operation
4 Solenoid operation
7
Pressure Rating
V 315 bar (4500 psi) on
ports P, A & B
8
Interface
5 ISO 4401, size 05-04-0-
05 ANSI/B93.7M-D05. ISO
4401, size 05-06-0-05 (with
L ports)
9
Spool Type (center
condition)
(see spool data)
2 All ports closed
9 All ports closed
(zero lap, 50N only)
33 P port closed, bleed A &
B to T
10
Spool/Spring
Arrangement
B Spring centered single
solenoid valve (solenoid “B”
only) Solenoid “A” for “V”
version, throttle valve
C Spring centered, dual
solenoid, directional valve
11
Spool Flow Rating
p = 5 bar (75 psi) per
metering flow path, e.g. B
to T. (For actual maximum
flow refer to power capacity
envelope curves.)
30 30 L/min
(7.9 USgpm)
50 50 L/min
(13.2 USgpm)
65 65 L/min
(17.2 USgpm)
70 70 L/min
(18.5 USgpm) ▲■
Meter-in/meter-out
Meter-out only
▲■ Type 2 spool only
12
Spool Metering Type
N Meter-in and meter-out
S Meter-out only
13
Flow Rating (“B” port
flow for asymmetric
spools) K(B)FDG
Valves Only
25 25 L/min (6.6 USgpm)
(50N25 only)
Omit for symmetrical spools
14
Manual Overrides
Z No manual overrides
15
Solenoids Energization
Identity
(non-integral amplifier types
KF only, omit for valves with
integral amplifier)
V Solenoid “A” is at port
“A” end and Solenoid
“B” is at port “B” end
independent of spool
type
Blank US ANSI B93.9
standard (energize
solenoid “A”, flow
symbol is (PA)
16
Command Input
(omit for valves with integral
amplifier)
M Electrical feature flag
(KF only)
M1
±10VDC (KBF only)
M2 4-20 mA (KBF only)
17
Solenoid Connector
(omit for valves with integral
amplifier KBF)
U1 ISO 4400/DIN 43650,
non-integral amplifier
type KF only (mating
plug supplied)
18
Electrical Connection
(KBF valves only)
PC7 7-pin connector
without plug
PE7 7-pin electrical plug
with mating half
PH7 As PE7 but with pin
“C” used for enable
signal
PR7 As PC7 but with pin
“C” used for enable
signal
19
Coil Rating
H 24 VDC amplifier
supply
20
Port T Pressure
Limit Code
6 For 2C**S spools
7 For all other spools
21
Design Number
1* & 2* Series
Subject to change
K (B) F * G 4 V - 5 - * * * * * * * * - Z - (V) - (M) - (U1)- (* * *) - H - * - *
WARNING
Valves with
integral amplifier
are supplied with or
without the metal 7-pin
plug. The Vickers plug,
part no. 934939, must be
correctly fitted to ensure
that the EMC rating and
IP67 rating are archieved.
The plug retaining nut must
be tightened with a torque
of 2-2,5 Nm (1.5-2.0 lbf ft)
to effect a proper a proper
seal.
5EATON Vickers
®
Proportional Valves KBFD/TG4V-5 V-VLPO-MC008-E1 April 2009
P T B L
P T B A L
P T B A L
P T B A L
7-pin
plug
A
Spool Data
Spool Symbols
Available Spools for
K(B)FDG4V-5
Spool type 9C**N,
meter-in/meter-out (zero lap)
Spool type 2C**N,
meter-in/meter-out
Spool type 2C50N25,
assymetric flow
Spool type 2C65S,
meter-out only
Spool 33C**N,
meter-in/meter-out
Spool type 33C50N25,
assymetric flow
Available Spools for
K(B)FTG4V-5
Spool type 2B**N,
meter-in/meter-out
Spool Type and Flow Rating
Symmetric Spools
Base line starting at p = 5 bar (75 psi) per metering flow pat, e.g. B to T. For actual
maximum flow refer to power capacity envelope curves.
Functional Symbols
Model Types KBFDG4V-5
Model Types KFDG4V-5
proporational directional
valve (requires amplifier
card)
Model Types KBFTG4V-5
proporational throttle
valve (with intergated
electronics)
Model Types KFTG4V-5
proporational throttle
valve (requires amplifier
card)
For K(B)FDG4V-5 Valves
Spool Spool Flow
Code Symbol Rating
2C75N45 2C 75 L/min (19.8 USgpm), “A” port flow
45 L/min (11.9 USgpm), “B” port flow
2C50N25 2C 50 L/min (13.2 USgpm), “A” port flow
25 L/min (6.6 USgpm), “B” port flow
33C50N25 33C 50 L/min (13.2 USgpm), “A” port flow
25 L/min (6.6 USgpm), “B” port flow
Asymmetric Spools
Figure preceding metering type designator, “N” (e.g. 2C***N) is flow rating P–A, or A–T
(“A” port flow); figure after “N” (N***) is flow rating P–B, or B–T (“B” port flow).
For K(B)FDG4V-5 Valves
Spool Code Spool Symbol Flow Rating
2C30N 2C 30 L/min (7.9 USgpm)
2C50N 2C 50
L/min (13.2 USgpm)
2C65S 2C 65
L/min (17.2 USgpm)
2C70N 2C 70
L/min (18.5 USgpm)
9C50N 9C 50
L/min (13.2 USgpm)
33C30N 33C 30
L/min (7.9 USgpm)
33C50N 33C 50
L/min (13.2 USgpm)
For K(B)FTG4V-5 Valves
Spool Code Spool Symbol Flow Rating
2B30N 2B 30 L/min (7.9 USgpm)
2B50N 2B 50
L/min (13.2 USgpm)
2B70N 2B 70 L/min (18.5 USgpm)
proporational directional
valve (with intergated
electronics)
6 EATON Vickers
®
Proportional Valves KBFD/TG4V-5 V-VLPO-MC008-E1 April 2009
Operating Data
K(B)FD/TG4V-5
Valves with Amplifier
KBFD/TG4V-5 Valves with Integral Amplifier
Data is typical with fluid at 36 cSt (168 SUS) and 50° C (122° F).
Power supply 24V DC (21 V to 36V including 10% peak-to-peak max. ripple)
max current 3A
Command signal
Voltage mode M1 0
to +10V DC, or 0 to -10V DC, or -10V to +10V DC
Input impedance 47
Common mode voltage to pin D 18V (max)
Current mode M2 4-20 mA
Input impedance 100
Max differential voltage to Pin E to Pin B 100mV
Valve enable signal for model codes PH7 & PR7
Enable >8.5V
(36V max)
Disable <6.5 V
Input impedance 10
7-pin plug connector Pin
Description
A
Power supply positive (+)
B Power supply 0V and current command return
C Not connected (PE7 & PC7)
C Valve enable (PH7 & PR7)
D Command signal (+V or current IN)
E Command signal (–V or current GND)
F Mounting input
G Protective ground
Electromagnetic compatibility (EMC)
Emmision (10V/m) EN
61326-2
Immunity (10V/m) EN 61326-2
Threshold command voltage
(minimum voltage for minimum flow) 0.25V
Monitor signal (pin F) KBFD valves ±
10V DC for full spool stroke
KBFT valves 0 to –10 V DC for full spool stroke
Output impedance 10
Power stage PWM frequency 10
kHz nominal
Step input response with flow through P–A–B–T
p = 5 bar (75 psi) per metering path, e.g. P–A
Required flow step: Time to reach 90% of required step:
0 – 100% 30 ms
100% – 0 40 ms
+90 – -90% (KBFDG4V3-3 only) 32 ms
Reproducibility, valve-to-valve (at factory settings):
Flow at 100% command signal 5%
Protection
Electrical Reverse
polarity protected
Environmental IEC 60529, Class IP65 & IP67
Ambient air temperature range for full performance
C to 70° C (32° F to 158° F)
Oil temperature range for full performance C to 70° C (32° F to 158° F)
Mimimum temperature at which -20°
C (-4° F)
valves will work at reduced performance
Storage temperature range -25°
C to +85° C (-13° F to +185° F)
Supporting products
Auxiliary electronic modules (DIN -rail mounting):
EHD-DSG-201-A-1* command signal generator See
catalog GB 2470
EHA-RMP-201-A-2* Ramp generator See
catalog GB 2410A
EHA-PSU-201-A-10 Power supply See
catalog GB 2410A
EHA-PID-201-A-20 PID controller See
catalog GB 2427
Operating Data
F
A
G
B
C
D
E
7EATON Vickers
®
Proportional Valves KBFD/TG4V-5 V-VLPO-MC008-E1 April 2009
Operating Data
KFD/TG4V-5
Valves without
Amplifier
KBFD/TG4V-5 Valves without Integral Amplifier – (requires a Eurocard Amplifier, Refer to Supporting Products)
Data is typical with fluid at 36 cSt (168 SUS) and 50° C (122° F).
Max current, at 50° C (122° F) 2,7 A
Coil reistance, at 20° C (68° F)
1,87
Step response
Step size (% of max spool stroke) T
ime to reach 90% of required step:
0 to 100% 31 ms
100% to 0 30 ms
+90 to -90% (KFDG4V-5 only) 45 ms
Type of protection, with electrical plugs fitted correctly IEC
60529, Class IP65
Electromagnetic compatibility (EMC)
Emmision (10V/m) EN
50081-2
Immunity (10V/m) EN 50082-2
Maximum allowable ambient air temperature 60°
C (140° F)
Maximum allowable oil temperature 60° C (140° F)
Supporting products:
Eurocard amplifiers
EEA
PAM 533 A/B/C/D/E/F See catalog GB-2464
KFD/TG4V-5 and KBFD/TG4V-5 Valves (All Valves)
Relative duty factor Continuous rating (ED = 100%)
Hysteresis with flow through P–A–B–T <1% of max stroke (center-to-offset)
Mass: KFDG4V-5
7,2 kg (15.86 lb) approx.
KBFDG4V-5 7,6 kg (16.76 lb) approx.
KFTG4V-5 5,5 kg (12.10 lb) approx.
KBFTG4V-5 5,9 kg (13.00 lb) approx.
Portable test equipment
EBA TEQ 460 A 10
See catalog V-ELAC-TM001-E
Pressure and Flow Rates
Maximum pressures, bar (psi)
Model Port L Condition Ports P, A, B T L
All models for normal usage Normally blocked by 315 (4500) 160 (2300) 160 (2300)
(L port not connected) mounting surface
For K(B)FDG4V-5**C**N-Z models only Drained directly to tank 315 (4500) 210 (3000) 10 (150)
a higher “T” port pressure is allowed if the
“L” port is connected directly to tank
8 EATON Vickers
®
Proportional Valves KBFD/TG4V-5 V-VLPO-MC008-E1 April 2009
(A)
P
B
(T)
0 40 80 120 160
0 10 20 30 40 50 USgpm 0 10 20 30 40 50 USgpm
Flow rate
100
200
300
315
0
1000
2000
3000
4000
4500
psi bar
A
P
(B)
(T)
(A)
P
B
(T)
or
0 40 80 120 160
Flow rate
100
200
300
315
0
1000
2000
3000
4000
4500
psi bar
A
P
B
T
or
A
P
B
T
081
0 40 80 120 160
040 10 20 30 50 USgpm
Flow rate
100
200
300
315
0
1000
2000
3000
4000
4500
psi bar
180
0 40 80 120 160
040 10 20 30 50 USgpm
Flow rate
100
200
300
315
0
1000
2000
3000
4000
4500
psi bar
Valve pressure drop
Valve pressure drop
Valve pressure dropValve pressure drop
Valve pressure drop
Looped Flow Path
A
P
B
T
180 L/min
0 60 120 180 240
0 4010 20 30 50
USgpm
Flow rate
100
200
300
315
0
1000
2000
3000
4000
4500
psi bar
A
P
B
T
60
Max. system pressure =
max. for port T: 210 bar (3000
psi)
300
70 80
2
B
3
0
N
2
B
5
0
N
2
B
7
0
N
2
B
3
0
N
2
B
5
0
N
2
B
7
0
N
2
B
7
0
N
2
B
5
0
N
*
*
C
3
0
N
*
*
C
5
0
N
2
C
7
0
N
2
C
6
5
S
2
C
7
0
N
*
*
C
5
0
N
*
*
C
3
0
N
L/min
180 L/min
L/min
L/min
Performance
Curves
Power Capacity
Envelopes
Single Solenoid Models:
K(B)FTG4V-5
Spool types as noted
Parallel Flow Path use
parallel flow path module:
KDGMA-5-616877-10R or
KDGMA-5-02-139150-10S
(see page 16)
Single Flow Path
Double Solenoid Models:
K(B)FDG4V-5
Spool types as noted
Single Flow Path
Looped Flow Path
Looped Flow Path
9EATON Vickers
®
Proportional Valves KBFD/TG4V-5 V-VLPO-MC008-E1 April 2009
KFD/TG4V-5
1 2 3 4 5 10
0
+3
3
6
20 30 40
60 80
135
90
45
0
Frequency (Hz)
)seerged( gal esahP
)Bd( oitar edutilpmA
1 2 3 4 5 10
0
+3
3
6
20 30 40
60 80
135
90
45
0
Frequency (Hz)
)seerged( gal esahP
)Bd( oitar edutilpmA
KBFD/TG4V-5
L/min
70
40
20
0
20 40 60 80
100
Command signal (% of max.)
USgpm
0
5
10
15
20
60
N07C2 ,N07B2
S56C2
N05C** ,N05B2
2
B
3
0
N
,
*
*
C
3
0
N
KFD/TG4V-5
1 2 3 4 5 10
0
+3
3
6
20 30 40
60 80
135
90
45
0
Frequency (Hz)
)seerged( gal esahP
)Bd( oitar edutilpmA
1 2 3 4 5 10
0
+3
3
6
20 30 40
60 80
135
90
45
0
Frequency (Hz)
)seerged( gal esahP
)Bd( oitar edutilpmA
KBFD/TG4V-5
L/min
70
40
20
0
20 40 60 80
100
Command signal (% of max.)
USgpm
0
5
10
15
20
60
N07C2 ,N07B2
S56C2
N05C** ,N05B2
2
B
3
0
N
,
*
*
C
3
0
N
Performance
Curves
Flow Gain Curves
K(B)FD/TG4V-5
Spool types as noted
When using the single
solenoid throttle valve
(K*FT), a dual flowpath
module (page 16) can be
used to approximately
double the flow rate.
Curves shown include
deadband compensation
provided for the KF valve by
the Eaton’s Vickers Eurocard
Amplifier EEA-PAM-535-*-32
(user adjustable).
KB valves are preset at the
factory to compensate for
the effect of spool overlap.
Frequency Response (Typical)
Q
x
= Q
d
p
x
p
d
For an amplitude of ± 25%
max. flow about the 50% flow ,
at p (P–B) = 5 bar (72 psi)
At other p values and within the
power capacity envelopes, flow rates
approximate to:
Single flowpath (e.g. P–A)
pressure drop, p = 5 bar
(72 psi) .
10 EATON Vickers
®
Proportional Valves KBFD/TG4V-5 V-VLPO-MC008-E1 April 2009
3rd angle
projection
70
(2.76)
97
(3.82)
13 (0.52)
clearance for
removal
335,0 (13.19)
181,5 (7.15)
Solenoid plug (ISO 4400/DIN 43650);
black, marked B, for V models, or
gray, marked A, for non-V models; see
in “Model Code”
15
Solenoid plug (ISO 4400/DIN 43650);
gray, marked A, for V models, or
black, marked B, for non-V models;
see in “Model Code”
Port A Port B
21,5 (0.85)
30
(1.18)
LVDT plug, gray 8 (0.32)
clearance for removal
Solenoid plug (ISO 4400/DIN 43650);
gray, marked A, for V models, or black,
marked B, for non-V models; see in
“Model Code”
)81.4( 601
15
4 holes thru Ø 7 (0.275)
275 (10.83)
Port A
Port B
15
:
15
Installation
Dimensions
NOTE: For optimum valve
operation, bleed the air from
the proportional solenoids at
initial start-up. This may be
done as follows:
• The valve may be pres-
surized by removing the
bleed screws until no
bubbles appear and then
reinstalling bleed screws,
or...
Remove both bleed
screws, and use a stan-
dard oil can nozzle to
pump fluid in one side
until it flows, free of air
bubbles, out the other
side. Reinstall screws.
If there is no inherent back
pressure in the tank port of
the circuit do not allow the
tank line to empty. This may
be prevented by installing a
check valve in the tank line.
The cracking pressure of the
check valve should be in the
range of 22 - 45 psi (1.5 - 3
bar).
* Bleed screw locations
Air bleed, Socket Head
Cap Screw.
Torque to 2,5-3,0 Nm
(2.0-2.5 lbf ft)
KFDG4V-5
mm (inch)
KFTG4V-5
mm (inch)
11EATON Vickers
®
Proportional Valves KBFD/TG4V-5 V-VLPO-MC008-E1 April 2009
7 pin connector plug
Fixing bolt
174
(6.85)
328
(12.91)
85
(3.34)
135
(5.31)
70
(2.76)
174
(6.85)
268
(10.55)
X X
XX
30 (1.18)
Port A
Port B
Port A
Port B
21,5 (0.85)
Installation
Dimensions
NOTE: For optimum valve
operation, bleed the air from
the proportional solenoids at
initial start-up. This may be
done as follows:
• The valve may be pres-
surized by removing the
bleed screws until no
bubbles appear and then
reinstalling bleed screws,
or...
Remove both bleed
screws, and use a stan-
dard oil can nozzle to
pump fluid in one side
until it flows, free of air
bubbles, out the other
side. Reinstall screws.
If there is no inherent back
pressure in the tank port of
the circuit do not allow the
tank line to empty. This may
be prevented by installing a
check valve in the tank line.
The cracking pressure of the
check valve should be in the
range of 22 - 45 psi (1.5 - 3
bar).
Warning
Valves with integral
amplifiers are
supplied with or without the
metal 7-pin plug. The Eaton
plug, part no. 934939, must
be correctly fitted to ensure
that the EMC rating and
IP67 rating are achieved. The
plug retaining nut must be
tightened with a torque of
2,0-2,5 Nm (1.5-2.0 lbf ft) to
effect a proper seal.
* Bleed screw locations
Air bleed, Socket Head
Cap Screw.
Torque to 2,5-3,0 Nm
(2.0-2.5 lbf ft)
KBFDG4V-5
mm (inch)
KBFTG4V-5
mm (inch)
12 EATON Vickers
®
Proportional Valves KBFD/TG4V-5 V-VLPO-MC008-E1 April 2009
Subplates and
Mounting Surfaces
General Description
If a subplate is not used,
a machined pad must be
provided for valve mounting.
Pad must be flat within
0,0127 mm (.0005 inch) and
smooth within 1,6 µm (63
microinch). Mounting bolts,
when provided by customer,
should be ISO 898 class
12.9 or better.
Dimensional Tolerances
Dimensional tolerance on
interface drawings is
± 0,2
mm (
±0.008”) except where
otherwise stated. ISO 4401
specifies inch conversion to
± 0.01”.
Conversion for Metric
ISO 4401 gives dimensions
in mm. Inch conversons are
accurate to 0.01” unless
othewise stated.
Mounting Bolt Tapping
ISO 4401 gives metric
thread tappings. Alternate
UNC tapping are Eaton’s
recommendations that allow
these plates and associated
valves to be used up to
their maximum pressures,
when using Eaton
recommended bolt kits,
or bolts of an equivalent
strength. It is recommended
that customer’s own
manifold blocks for UNC
bolts should be tapped to
the minimum depths given
in the footnotes.
Subplates
Description and Mass kg (lb) Fucntional Symbol Model
Code Max. Pressure
Single-station subplate; KDGSM-5-67805-20 210 bar (3000 psi)
rear ports P, T, A, B; side port L (SAE/UNF ports)
Cast iron 1,3 (2.9) KDGSM-5-615225-10 315 bar (4500 psi)
1/2” BSPF ports
KDGSM-5-615226-10
3/4”BSPF ports
EKDGSM-01Y-10-R 280 bar (4000 psi)
P T B A L
L
P T B A
13EATON Vickers
®
Proportional Valves KBFD/TG4V-5 V-VLPO-MC008-E1 April 2009
13
11,5
(0.45)
P
A B
T
N
M
101,6 (4.0)
12,7 (0.5)
79,4 (3.12)
68,3
(2.7)
23,1
(0.9)
11,2 (0.44)
4 holes Ø 10,8 (0.42 dia) through,
spotfacedØ 17,5 (0.66 dia)
4 holes tapped according to model type:
For DGSM-01 and KDGSM-5 models
(UNC port threads),
1
/
4
-20 UNC-2B x 12,7 (0.5) deep.
For EDGSM-01(*) and EKDGSM-01Y
models (BSPF port threads),
M6 x 15,8 (0.62) deep.
92,1
(3.62)
114,3
(4.5)
P T B A L
L
P T B A
L
W
K
E
69,0
(2.7)
F
68,3
(2.7)
47,5
(1.5)
C
H
J
G
90,4
(3.56)
5,6
(0.22)
Side port L,
EKDGSM-01Y only:
9
/
16
-18 UNF-2B x
12,7 (0.5) full thread depth
Rear port L, KDGSM-5-676805 only:
G
1
/
8
(
1
/
8
BSPF) x 12,0 (0.47) full thread depth
11,2
(0.44)
Installation
Dimensions
Subplates with Rear Ports P, T, A, B
Maximum Pressure 210 bar (3000 psi)
Model types: KDGSM-5-676805-2*
(with rear port L)
EKDGSM-01Y-1*-R
(with side port L)
Port Threads
Ports P, T, A, B Threads Ports P, T, A, B Threads
Model Port thread
210 bar (3000 psi)
KDGSM-5-676805-2* 3/4 -16 UNF-2B x 14,0 (0.56) full thread depth
280 bar (4000 psi)
EKDGSM-01Y-10-R G
1/2 (1/2” BSPF) X 15,0 90.59) full thread depth
Dimensions
Model C
E F G H J K M N W
210 bar (3000 psi) 45,2 42,1 19,0 68,3 45,2 23,8 42,1 31,8 23,9 57,1
KDGSM-5-676805-2*
(1.78) (1.66) (0.75) (2.69) (1.78) (0.94) (1.7) (1.25) (0.94) (2.25)
280 bar (4000 psi) 39,7 40,5 9,9 70,6 69,7 10,7 40,5 36,5 28,6 72,6
EKDGSM-01Y-1*-R (1.56) (1.56) (0.39) (2.78) (1.56) (0.42) (1.59) (1.44) (1.13) (2.86)
14 EATON Vickers
®
Proportional Valves KBFD/TG4V-5 V-VLPO-MC008-E1 April 2009
14
LP T B A
P
A
B
T
89,0 (3.5)
80,0 (3.15)
67,0
(2.6)
4 holes M6 x
14,0 (0.55) full
thread depth
115,0
(4.6)
L
46,0
(1.81)
77,5
(3.1)
88,0 (3.5)
Port L, G
1
/
4
(
1
/
4
BSPF) x 12,0 (0.47),
spotfaced to Ø 24,0 (0.94 dia)
120,0 (4.8)
23,0
(0.9)
92,0
(3.62)
17,0
(0.7)
47,5
(1.9)
12,5 (0.5)
Z Y
42,0
(1.7)
Port L, Ø 4,0 (0.16 dia)
Ports P, T, A, B,
Ø 10,5 (0.41 dia)
Part Section A-A
40,0
(1.6)
5,0
(0.2)
A
A
R
ecommended panel cut-out to
clear fittings,Ø 108,0 (4.25 dia)
75,0
(3.0)
4 holes Ø 10,5 (0.41 dia)
13,0 (0.51)
1,0
(0.04)
Installation
Dimensions
Subplates with Rear
Ports P, T, A, B, L
Maximum Pressure 315 bar (4500 psi)
Model types: KDGSM-5-615225-1*
KDGSM-5-615226-1*
All dimensions in mm (inches)
Ports P, T, A, B
Model Y
Thread Z Diameter
KDGSM-5-615225-10 G1/2 (1/2” BSPF) x 14,0 (0.55) full thread depth 30,0 (1.18)
KDGSM-5-615226-10 G3/4 (3/4” BSPF) X 16,0 (0.63) full thread depth 33,0 (1.30)
15EATON Vickers
®
Proportional Valves KBFD/TG4V-5 V-VLPO-MC008-E1 April 2009
Installation
Dimensions
Mounting Surfaces
to ISO 4401
(Size 05)
This interface conforms to:
ISO 4401-05-04-0-05
ANSI/B93.7M (and NFPA)
size 05
Interface with Additional
Drain Port
The interface conforms to
ISO 4401-05-06-0-05
Typically used for proportional
and other valves requiring an
additional drain port, e.g.:
K(B)FDG4V-5
K(B)FTG4V-5
15
37,3
(1.47)
5 ports Ø 11,2 (0.44 dia)
including optional tank port
27,0
(1.06)
16,7 (0.66)
6,3 (0.25)
3,2 (0.12)
50,8
(2.0)
46,0 0,1
(1.81 0.004)
32,5 (1.28)
90,0 (3.54) min.
P
A
B
T
A
T
B
54,0 0,1
(2.12 0.004)
69,0
(2.72)
min.
21,4 (0.84)
P
A
B
T
A
T
B
0,5 (0.02)
11,0 (0.433)
L
Ø 3,0 (0.12 dia)
16 EATON Vickers
®
Proportional Valves KBFD/TG4V-5 V-VLPO-MC008-E1 April 2009
16
Parallel Path Flow Module
.
P T B A
P T B A
L
L
35,0
(1.38)
4,0
(0.16)
4 holes Ø5,6 (0.22)
A
T
A
L
P
Do not remove this
closure plug, or
others in side faces
S
upplied with port L plugged. Remove plug
for external drain connection if required.
(See table for tapping and socket A/F sizes)
T
B
B
122,0 (4.8)
116,0 (4.6)
70,0
(2.8)
18,5 (0.73)
Nameplate
Parallel Path
Flow Module
Size 05
Parallel-Flow-Path Modules
KDGMA-5-616877-1*-R
KDGMA-5-02-139150-1*-S
A, T
A
and T
B
ports at
subplate face are blind
holes fitted with O-seals.
Socket Wrench A/F Mass
Model Por
t L Thread for Plug Removal (approx)
KDGMA-5-616877-1*-R G1/4 (1/4” BSPF) x 11,0 (0.43) full thread depth 6,0 (0.23) 1,5 kg (3.3 lb)
KDGMA-5-02-139150-1*-S 9/16”-18 UNF x 12,7 (0.5) full thread depth 6,3 (0.25) 1,5
kg (3.3 lb
Max. Pressures and Flow Ratings
No functional limitations; dependent on valves used.
Typically used for doubling
effective flow capability of
single solenoid proportional
valves (throttle valves),
as illustrated in "Typical
Applications'.
17EATON Vickers
®
Proportional Valves KBFD/TG4V-5 V-VLPO-MC008-E1 April 2009
Electrical
Information
Block Diagram
Voltage Input (M1)
KBFDG4V-5
KBFDG4V-5 Wiring
Connections must be made
via the 7-pin plug mounted
on the amplifier. See page
15 of this leaflet and Eaton’s
Installation Wiring Practices
for Vickers
®
Electronic
Products, leaflet 2468.
Recommended cable sizes
are:
Power cables:
For 24V supply 0,75 mm
2
(18 AWG) up to 20m (65 ft)
1,00 mm
2
(16 AWG) up to
40m (130 ft)
Signal cables:
0,50 mm
2
(20 AWG)
Screen (shield):
A suitable cable would have
seven cores, a separate
screen for the signal wires
and an overall screen.
Cable outside diameter 8,0–
10,5 mm (0.31–0.41 inches)
See connection diagram on
next page.
KFDG4V-5 Wiring
Wiring details for these
valves are contained in
the appropriate Eurocard
literature and Eaton’s
Installation Wiring Practices
for Vickers
®
Electronic
Products leaflet 2468.
Command Signals and Outputs, M1
7-pin plug Flow direction
Pin D Pin E
Positive OV
OV Negative
P to A
U
d
- U
e
= Positive
Negative OV
OV Positive
P to B
U
d
- U
e
= Negative
Of fset
Modulator
Valve envelope
7-pin plug connections
+24V
A
B
D
E
F
G
P
ower 0V
Enable or
n
ot connected
Protective
ground
Non-inverting
Inverting
Command
signal
voltage,
see table
Compensation
network
+15V
0V
15V
+24V
L
VDT
C
Monitor output
Gain
+24V
Solenoid
drive
Pin C is used for a valve enable signal with electrical connections PH7 and PR7.
WARNING
All power must
be switched off
before connecting/discon-
necting any plugs.
18 EATON Vickers
®
Proportional Valves KBFD/TG4V-5 V-VLPO-MC008-E1 April 2009
Electrical
Information
Block Diagram
Current Input (M2)
KBFDG4V-5
KBFDG4V-5 Wiring
Connections must be made
via the 7-pin plug mounted
on the amplifier. See page
15 of this leaflet and Eaton’s
Installation Wiring Practices
for Vickers
®
Electronic
Products, leaflet 2468.
Recommended cable
sizes are:
Power cables:
For 24V supply
0,75 mm2 (18 AWG) up to
20m (65 ft) 1,00 mm2 (16
AWG) up to 40m (130 ft)
Signal cables:
0,50 mm2 (20 AWG)
Screen (shield):
A suitable cable would have
seven cores, a separate
screen for the signal wires
and an overall screen.
Cable outside diameter 8,0–
10,5 mm (0.31–0.41 inches)
See connection diagram on
next page.
KFDG4V-5 Wiring
Wiring details for these
valves are contained in the
appropriate Eurocard literature
and Eaton’s Installation
Wiring Practices for Vickers
®
Electronic Products leaflet
2468.
Command Signals and Outputs, M2
7-pin plug
Pin D Pin E Pin B Flow direction
More than Current Power
12 mA return ground P to A
Less than Current Power
12 mA return ground P to B
WARNING
All power must
be switched off
before connecting/discon-
necting any plugs.
Offset
Modulator
Valve envelope
7-pin plug connections
+24V
A
B
D
E
F
G
P
ower 0V
Enable or
not connected
Protective ground
Command +4 to 20 mA
Compensation
network
+15V
0V
-15V
+24V
LVDT
C
Monitor output
+24V
Solenoid
drive
Gain
F1
R1
F2
Return
Pin C is used for a valve enable signal with electrical connections PH7 and PR7.
R1 shunt resistor 100R
F1, F2 resettable fuse
19EATON Vickers
®
Proportional Valves KBFD/TG4V-5 V-VLPO-MC008-E1 April 2009
Electrical
Information
Wiring Connections
Voltage Input (M1)
Spool position monitor
voltage (pin F) will be
referenced to the KB valve
local ground.
WARNING
Do not ground
pin C.
Wiring Connections for
M1 Valves with Enable
Feature
Note: In applications
where the valve must
conform to European
RFI/EMC regulations, the
outer screen (shield) must
be connected to the outer
shell of the 7-pin connector,
and the valve body must
be fastened to the earth
ground. Proper earth
grounding practices must
be observed in this case, as
any differences in command
source and valve ground
potentials will result in a
screen (shield) ground loop.
Input
User Panel
P
ower
Supply
Demand
Signal
Spool
P
osition
Monitor
0
V must be
connected to ground
Enclosure
+24V
0V
±10V
Connector
shell
O
uter Screen
KB..PC7/PE7 valve
A
B
D or E
0V
0V
C
Drain Wire
Inner Screen
G
F
Valve
must be
connected
to ground
via
subplate
0V
Input
User Panel
P
ower
Supply
Demand
Signal
Spool
Position
Monitor
+24V
±10V
Connector
shell
O
uter Screen
A
B
D
or E
0V
0V
C
Drain Wire
Inner Screen
E or D
G
F
KB..PR7/PH7 valve
Enable
Signal
+8.5V
t
o 36V
0V
Enclosure
Valve
must be
connected
to ground
via
subplate
0V must be
connected to ground
20 EATON Vickers
®
Proportional Valves KBFD/TG4V-5 V-VLPO-MC008-E1 April 2009
Electrical
Information
Wiring Connections
Current Input (M2)
Spool position monitor
voltage (pin F) will be
referenced to the KB valve
local ground.
WARNING
Do not ground
pin C.
Wiring Connections for
M2 Valves with Enable
Feature
Note: In applications
where the valve must
conform to European
RFI/EMC regulations, the
outer screen (shield) must
be connected to the outer
shell of the 7-pin connector,
and the valve body must
be fastened to the earth
ground. Proper earth
grounding practices must
be observed in this case, as
any differences in command
source and valve ground
potentials will result in a
screen (shield) ground loop.
WARNING
Electromagnetic
Compatibility (EMC)
It is necessary to ensure
that the valve is wired up
as above. For effective
protection the user electrical
cabinet, the valve subplate
or manifold and the cable
screens should be connected
to efficient ground points.
The metal 7-pin connector
part no. 934939 should
be used for the integral
amplifier. In all cases both
valve and cable should be
kept as far away as possible
from any sources of elec-
tromagnetic radiation such
as cables carrying heavy
current, relays and certain
kinds of portable radio
transmitters, etc. Difficult
environments could mean
that extra screening may
be necessary to avoid the
interference.
It is important to connect
the 0V lines as shown
above. The multi-core cable
should have at least two
screens to separate the
Input
User Panel
Power
Supply
Demand
Signal
Spool
P
osition
Monitor
0
V must be
connected to ground
Enclosure
+24V
4 - 20 mA
0V
Valve
must be
connected
to ground
via
subplate
Connector
shell
O
uter Screen
KB..PC7/PE7 valve
A
B
E
0V
0V
C
Drain Wire
Inner Screen
G
F
D
0V
Input
User Panel
Power
Supply
Demand
Signal
Spool
P
osition
Monitor
+24V
Connector
shell
4 - 20 mA
O
uter Screen
A
B
E
0V
0V
C
Drain Wire
Inner Screen
D
G
F
KB..PR7/PH7 valve
0V must be
connected to ground
Enable
Signal
+8.5V
t
o 36V
0V
Enclosure
Valve
must be
connected
to ground
via
subplate
demand signal and monitor
output from the power
lines.
The enable line to pin C
should be outside the
screen which contains the
demand signal cables.
21EATON Vickers
®
Proportional Valves KBFD/TG4V-5 V-VLPO-MC008-E1 April 2009
Application Data
Fluid Cleanliness
Proper fluid condition is essential for long and satisfactory
life of hydraulic components and systems. Hydraulic fluid
must have the correct balance of cleanliness, materials
and additives for protection against wear of components,
elevated viscosity and inclusion of air.
Recommendations on contamination control methods
and the selection of products to control fluid condition
are included in Eaton’s publication 9132 or 561, “Vickers
Guide to Systemic Contamination Control”. The book also
includes information on the Eaton’s concept of “ProActive
Maintenance”.
The following recommendations are based on ISO
cleanliness levels at 2 µm, 5 µm and 15 µm:
For products in this catalog the recommended levels are:
0 to 70 bar (1000 psi) . . . . . . . . . . . . . . 18/16/13
70 + bar (1000 + psi) . . . . . . . . . . . . . . . 17/15/12
Eaton products, as any components, will operate with
apparent satisfaction in fluids with higher cleanliness codes
than those described. Other manufacturers will often
recommend levels above those specified.
Experience has shown, however, that life of any hydraulic
components is shortened in fluids with higher cleanliness
codes than those listed above. These codes have been
proven to provide a long trouble-free service life for the
products shown, regardless of the manufacturer.
Hydraulic Fluids
Materials and seals used in these valves are compatible
with antiwear hydraulic oils, and non-alkyl-based phosphate
esters. The extreme operating viscosity range is 500 to
13 cSt (2270 to 70 SUS) but the recommended running
range is 54 to 13 cSt (245 to 70 SUS). For further technical
information about fluids see “Technical Information” leaflet
B-920 or I-286S.
Installation
The proportional valves in this catalog can be mounted in
any attitude, but it may be necessary in certain demanding
applications, to ensure that the solenoids are kept full
of hydraulic fluid. Good installation practice dictates that
the tank port and any drain port are piped so as to keep
the valves full of fluid once the system start-up has been
completed.
Mounting Bolt Kits
For K(B)FD/TG4V-5
BKDG01633M (metric)
BK869705 (inch)
If not using Eaton recommended bolt kits, bolts used should be to ISO 898, 12.9 or better.
Seal Kits
KFD/TG4V-5 . . . . . . . . . . . . . . . . . . . . . . . . 565110
KBFD/TG4V-5-1* . . . . . . . . . . . . . . . . . .02-332751
Plugs
KBFDG4V
7-pin plug (metal) . . . . . . . . . . . . . . . . . . . . 934939
7-pin plug (plastic). . . . . . . . . . . . . . . . . . . . 694534
(metal plug must be used for full EMC protection)
NOTE: An alternative metal connector which gives EMC
protection but not IP67 rating is available from ITT-Cannon,
part number CA06-COM-E-14S-A7-S.
KFDG4V
Solenoid (black) . . . . . . . . . . . . . . . . . . . . . 710775
Solenoid (gray) . . . . . . . . . . . . . . . . . . . . . . 710776
LVDT (gray) . . . . . . . . . . . . . . . . . . . . . . . . . 458939
Extension Cable
Extension Cable: Adapter for extending seven core cable
when changing from KA to KB valve and existing wiring is
not long enough. Consists of a 7-pin plug, a 7-pin socket
and a length of cable, fully assembled for ease of use.
Extension Cable . . . . . . . . . . . . . . . . . . . . . 944450
Service Information
The products from this range are preset at the factory for
optimum performance; disassembling critical items would
destroy these settings. It is therefore recommended that
should any mechanical or electronic repair be necessary
they should be returned to the nearest Eaton repair center.
The products will be refurbished as necessary and retested
to specification before return.
Field repair is restricted to the replacement of the seals.
NOTE: The feedback/solenoid assembly installed in this
valve should not be disassembled.
Eaton
Hydraulics Group USA
14615 Lone Oak Road
Eden Prairie, MN 55344
USA
Tel: 952-937-9800
Fax: 952-294-7722
www.eaton.com/hydraulics
Eaton
Hydraulics Group Europe
Route de la Longeraie 7
1110 Morges
Switzerland
Tel: +41 (0) 21 811 4600
Fax: +41 (0) 21 811 4601
Eaton
Hydraulics Group Asia Pacific
11th Floor Hong Kong New World Tower
300 Huaihai Zhong Road
Shanghai 200021
China
Tel: 86-21-6387-9988
Fax: 86-21-6335-3912
© 2009 Eaton Corporation
All Rights Reserved
Printed in USA
Document No. V-VLPO-MC008-E1
April 2009