K(B)FD/TG4V-3, 1*/2* Series
Pressures to 350 bar (5000 psi)
Vickers
®
Proportional Valves
Proportional Directional Valves with Feedback
2 EATON Vickers
®
Proportional Valves KBFD/TG4V-3 V-VLPO-MC007-E1 April 2009
Table of Contents
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Typical Section View . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Model
Code . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Spool
Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Functional
Symbols . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Operating
Data
Valves with Amplifier, KBFD/TG4V-3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
V
alves without Amplifier,KFD/TG4V-3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
KBFD/TG4V
-3 & KFD/TG4V-3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Pressure
and Flow Rates . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Performance
Curves
Power Capacity Envelopes, Single Solenoid Models . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Power
Capacity Envelopes, Double Solenoid Models . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Flow
Gain Curves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Frequency
Response . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Installation
Dimensions
KFDG4V-3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
KFTG4V
-3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
KBFDG4V
-3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
KBFTG4V
-3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Subplates
and Mounting Surfaces
Parallel Path Flow Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Subplate
Functional Symbol . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Interface
with Additional Drain Port . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Installation
Dimensions, KDGVM-3-1*-R . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Installation
Dimensions, KDGVM-3-676803-1* . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Mounting
Surface Interface to ISO 4401 (Size 03) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Electrical
Information
Block
Diagram Voltage Input (M1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Block
Diagram Current Input (M2) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Wiring
Connection Voltage Input (M1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Wiring
Connections Current Input (M2) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Application
Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
3EATON Vickers
®
Proportional Valves KBFD/TG4V-3 V-VLPO-MC007-E1 April 2009
Introduction
General Description
Eaton’s Vickers
®
K(B)FD/
TG4V proportional valves
are designed to provide a
controlled oil flow in direct
proportion to a command
signal. They are available
in two types; a double
solenoid version that will
provide reversible flow to
an actuator and a single
solenoid throttle version that
provides a single direction of
flow. Hydrostats are available
for load compensation and
parallel flow path modules
are available that will boost
the flow capacity of single
solenoid throttle versions
to nearly twice that of the
standard valve.
Additionally, both of these
valve types can be supplied
with or without an integral
amplifier built directly onto
the valve.
KFD/TG4V-3
This version is supplied
without the integral
amplifier
.
Features and Benefits
• Wide range of spool and
flow rate options
Electronic feedback LVDT
ensures accurate spool
position control
• Vibration and shock
tested
Supported by a broad
range of amplifiers and
auxiliary function modules
• Full CE electromagnetic
compatibility
KBFD/TG4V-3
A range of proportional
directional and throttle
valves with integral control
electronics.
Factory-set
adjustments of gain, spool
deadband compensation
and offset ensure consistent
repeatability valve-to-valve.
The only electrical inputs
required are power supply
(24V) and a voltage
command signal of
± 10V
or 4-20 mA. The amplifier
is housed in a robust metal
enclosure, sealed against
ingress of water and other
fluids. Electrical connections
are via a standard 7-pin plug.
A spool position monitor
pin allows the function of
the valve to be electrically
monitored. Ramp functions,
if required, can be generated
externally.
Features and Benefits
• Factory-sealed adjust-
ments
ensure valve-to-
valve reproducibility
• Installation wiring reduced
and simplified
• Standard 7-pin connector
• Standard 24V DC supply
with wide tolerance band
• Optional
± 10V DC or
4-20 mA command
signals
Valve with integrated
amplifier selected,
ordered, delivered and
installed as one perfor-
mance-tested
package
• Spool position monitor
pin
to help with trouble-
shooting
Simple valve removal and
replacement for service
(plug and play)
• Vibration and shock tested
• Auxiliary DIN rail mounted
electronic function mod-
ules
available
• Full CE electromagnetic
compatibility
IP65 and IP67 valve
environmental
protection
rating
Optional valve enable
function
Typical Section View
KBFD/TG4V-3-*PE7, 1* Design
4 EATON Vickers
®
Proportional Valves KBFD/TG4V-3 V-VLPO-MC007-E1 April 2009
Model Codes
321
76
4 9
8
5 17161110 1312
14 15
1918 2120
1
Valve Type
K Proportional valve
2
Integral Amplifier
B Integral amplifier “B”
series.
Omit for models
without integral amplifier
3
Feedback Arrangement
F Spool position
4
Control Type
D Directional valve
T Throttle valve
5
Mounting
G Subplate mounted
6
Operation
4 Solenoid operation
7
Pressure Rating
V 350 bar (5000 psi) on
ports
P, A & B
8
Interface
3 ISO 4401, size 03-02-0-
94
ANSI/B93.7M-D03
9
Spool Type (center
condition) (see spool
data, page 5)
2 All ports closed
5
All ports closed (zero lap)
33 P port closed, bleed A &
B to T
10
Spool/Spring
Arrangement
B Spring centered single
solenoid
valve (solenoid “B”
only) Solenoid “A” for “V”
version, Throttle valve
C Spring centered, dual
solenoid,
Direction valve
11
Spool Flow Rating
p
= 5 bar (75 psi) per
metering flow path, e.g. B
to T. (For actual maximum
flow refer to power capacity
envelope curves.
03 3 L/min (0.79 USgpm)
07 7 L/min (1.85 USgpm)
13 13 L/min (3.43 USgpm)
20 2
0 L/min (5.28 USgpm)
28 28 L/min (7.40 USgpm)
3
0 3
0 L/min (7.92 USgpm)
Meter
-in/meter-out
Meter
-out only; type 2
spool only
Fine
meter-in/meter-out
5C
Spool only
12
Spool Metering Type
N Meter-in and meter-out
F Fine meter-in and meter-
out
(only 03 spool)
S Meter-out only
13
Flow Rating (“B” port
flow for asymmetric
spools) K(B)FDG
Valves only
10 10 L/min (2.64 USgpm)
(20N10 only)
Omit for symmetrical spools
14
Manual Overrides
Z No manual overrides
15
Solenoids Energization
Identity
(non-integral
amplifier types
KF only, omit for valves with
integral amplifier)
V Solenoid “A” is at
port “A” end and Solenoid
“B” is at port “B” end
independent of spool type
Blank US ANSI B93.9
standard
(energize solenoid
“A”, flow symbol is (PA)
16
Command Input
M Electrical feature flag
(KF
only)
M1
± 10VDC (KBF only)
M2 4-20 mA (KBF only)
17
Solenoid Connector
Omit for valves with integral
amplifier KBF
U1 ISO 4400/DIN 43650,
non-integral
amplifier
type KF only (mating
plug supplied)
18
Electrical Connection
(KBF valves only)
PC7 7-pin connector without
plug
PE7 7-pin electrical plug
with
mating half
PH7 As PE7 but with pin
“C”
used for enable
signal
PR7 As PC7 but with pin
“C”
used for enable
signal
19
Coil Rating
H 24 VDC amplifier supply
20
Port T Pressure Limit
Code
6 For 2C**S spools
7 For all other spools
21
Design Number
1* & 2* Series
Subject to change
K (B) F * G 4 V - 3 - * * * * * * * * - Z - (V) - (M) - (U1) - (* * *) - H - * - *
WARNING
Valves with integral
amplifier are
supplied with or without the
metal 7-pin plug. The Eaton
plug, part no. 934939, must
be correctly fitted to ensure
that the EMC rating and
IP67 rating are achieved. The
plug retaining nut must be
tightened with a torque of
2-2,5 Nm (1.5-2.0 lbf ft) to
effect a proper a proper seal)
5EATON Vickers
®
Proportional Valves KBFD/TG4V-3 V-VLPO-MC007-E1 April 2009
P T B L
P T B A L
P T B A L
P T B A L
7-pin
plug
7-pin
plug
A
Spool Data
Spool Symbols
Available Spools for
K(B)FDG4V-3
Spool type 2C**N,
meter
-in/meter-out
Spool type 5C**N,
meter
-in/meter-out (zero lap)
Spool type 2C20N10,
asymmetric flow
Spool type 2C28S,
meter
-out only
Spool 33C**N, meter-in/
meter-out
Spool type 33C20N10,
asymmetric flow
Available Spools for
K(B)FTG4V-3
Spool type 2B**N,
meter
-in/meter-out
Spool Type and Flow Rating
Symmetric Spools
Base line starting at p = 5 bar (75 psi) per metering flow pat, e.g. B to T. For actual
maximum
flow refer to power capacity envelope curves.
Functional Symbols
Model Types KBFDG4V-3
proportional directional
valve
(with integrated
electronics)
Model
Types KFDG4V-3
proportional directional
valve
(requires amplifier
card)
Model
Types KFTG4V-3
proportional throttle
valve
(requires amplifier
card)
For K(B)FDG4V-3 Valves
Spool Spool Flow
Code Symbol Rating
2C20N10 2C 20 L/min (5.28 USgpm), “A” port flow
10 L/min (2.64 USgpm), “B” port flow
33C20N10 33C 20 L/min (5.28 USgpm), “A” port flow
10 L/min (2.64 USgpm), “B” port flow
Asymmetric Spools
Figure preceding metering type designator, “N” (e.g. 2C***N) is flow rating P–A, or A–T
(“A” port flow); figure after “N” (N***) is flow rating P–B, or B–T (“B” port flow).
For K(B)FDG4V-3 Valves
Spool Code Spool Symbol Flow Rating
2C03F 2C 3 L/min (0.79 USgpm)
2C07N 2C 7 L/min (1.85 USgpm)
2C13N 2C 13 L/min (3.43 USgpm)
2C20N 2C 20 L/min (5.28 USgpm)
2C30N 2C 30L/min (7.92 USgpm)
2C28S 2C 28 L/min (7.40 USgpm)
33C03F 33C 3 L/min (0.79 USgpm)
33C07N 33C 7 L/min (1.85 USgpm)
33C13N 33C 13 L/min (3.43 USgpm)
33C20N 33C 20 L/min (5.28 USgpm)
5C30N 5C 30/min (7.92 USgpm)
For K(B)FTG4V-3 Valves
Spool Code Spool Symbol Flow Rating
2B03F 2B 03 L/min (0.79 USgpm)
2B07N 2B 07 L/min (1.85 USgpm)
2B13N 2B 13 L/min (3.43 USgpm)
2B20N 2B 20 L/min (5.28 USgpm)
Model Types KBFTG4V-3
proportional throttle
valve
(with integrated
electronics)
6 EATON Vickers
®
Proportional Valves KBFD/TG4V-3 V-VLPO-MC007-E1 April 2009
Operating Data
K(B)FD/TG4V-3
Valves with Amplifier
KBFD/TG4V-3 Valves with Integral Amplifier
Data is typical with fluid at 36 cSt (168 SUS) and 50° C (122° F).
Power supply 24V DC (21 V to 36V including 10% peak-to-peak max. ripple)
max current 3A
Command signal
Voltage mode M1 0 to +10V DC, or 0 to -10V DC, or -10V to +10V DC
Input impedance 47
Common mode voltage to pin B 18V (max)
Current mode M2 4-20 mA
Input impedance 100
Max differential voltage to pin E to pin D 100 mV
Valve enable signal for model codes PH7 & PR7
Enable >8.5V (36V max)
Disable <6.5 V
Input impedance 10
7-pin plug connector Pin Description
A Power supply positive (+)
B Power Supply 0V and current command return
C Not connected (PE7 & PC7)
C Valve enable (PH7 & PR7)
D Command signal (+V or current IN)
E Command signal (–V or current GND)
F Mounting input
G Protective ground
Electromagnetic compatibility (EMC)
Emmission (10V/m) EN 61326-2
Immunity (10V/m) EN 61326-2
Threshold command voltage
(minimum
voltage for minimum flow) 0.25V
Monitor signal (pin F) KBFD valves ± 10V DC for full spool stroke
KBFT valves 0 to -10 V DC for full spool stroke
Output impedance 10
Power stage PWM frequency 10 kHz nominal
Step input response with flow through P–A–B–T
p=5 bar (75 psi) per metering path, e.g. P–A
Required flow step: Time to reach 90% of required step:
0 – 100% 17 ms
100% – 0 16 ms
+90 – -90% (KBFDG4V-3 only) 25 ms
Reproducibility, valve-to-valve (at factory settings):
Flow at 100% command signal 5%
Protection
Electrical Reverse polarity protected
Environmental I EC 60529, Class IP65 and IP67
Ambient air temperature range for full performance C to 70° C (32° F to 158° F)
Oil
temperature range for full performance C to 70° C (32° F to 158° F)
Minimum temperature at which -20° C (-4° F)
valves
will work at reduced performance
Storage temperature range -25° C to +85° C (-13° F to +185° F)
Supporting products
Auxiliary electronic modules (DIN -rail mounting):
EHD-DSG-201-A-1* command signal generator See catalog GB 2470
EHA-RMP-201-A-2* Ramp generator See catalog GB 2410A
EHA-PID-201-A-2* PID controller See catalog GB 2427
EHA-PSU-201-A-10 Power supply See catalog GB 2410A
F
A
G
B
C
D
E
View of pins of fixed half
7EATON Vickers
®
Proportional Valves KBFD/TG4V-3 V-VLPO-MC007-E1 April 2009
Operating Data
KFD/TG4V-3
Valves without
Amplifier
KFD/TG4V-3 Valves without Integral Amplifier (requires a Eurocard amplifier, refer to Supporting Products)
Data is typical with fluid at 36 cSt (168 SUS) and 50° C (122° F).
Max current, at 50° C (122° F) 2,7 A
Coil resistance, at 20° C (68° F) 1,87
Step
response
Step
size (% of max spool stroke) Time to reach 90% of required step:
0 100% 18 ms
100% 0 19 ms
+90 -90% (KBFDG4V3-3 only) 30 ms
Type of protection, with electrical plugs fitted correctly IEC60529, Class IP65
Electromagnetic compatibility (EMC)
Emmision (10V/m) EN 50081-2
Immunity (10V/m) EN 50082-2
Maximum allowable ambient air temperature 60° C (140° F)
Maximum
allowable oil temperature 60° C (140° F)
Supporting products:
Eurocard amplifiers
EEA PAM 533 A/B/C/D/E/F See catalog GB-2464
KFD/TG4V-3 and KBFD/4V-3 Valves (All Valves)
Relative duty factor Continuous rating (ED = 100%)
Hysteresis with flow through P–A–B–T <1% of max stroke (center-to-offset)
Mass: KFDG4V-3 2,7 kg (5.9 lb) approx.
KBFDG4V-3 3,1 kg (6.8 lb) approx.
KFTG4V-3 2,1 kg (4.6 lb) approx.
KBFTG4V-3 2,5 kg (5.5 lb) approx.
Portable test equipment
EBA TEQ 460 A 10 See catalog V-ELAC-TM001-E
Pressure and Flow Rates
Maximum pressures, bar (psi)
Model Port L Condition Ports P, A, B T L
All models for normal usage Normally blocked by 315 (4500) 160 (2300) 160 (2300)
(L port not connected) mounting surface 350 (5000) 105 (1500)
105 (1500)
For K(B)FDG4V-3**C**N/F-Z models only Drained directly to tank 350 (5000) 210 (3000) 10 (150)
a
higher “T” port pressure is allowed if the
“L” port is connected directly to tank.
8 EATON Vickers
®
Proportional Valves KBFD/TG4V-3 V-VLPO-MC007-E1 April 2009
Performance
Curves
Power Capacity
Envelopes
Single Solenoid Models:
K(B)FTG4V-3
Spool types as noted
Double Solenoid Models:
K(B)FDG4V-3
Spool types as noted
9EATON Vickers
®
Proportional Valves KBFD/TG4V-3 V-VLPO-MC007-E1 April 2009
L/min
8
6
4
2
0
20 40 60 80
USgpm
0
20
1.5
1.0
0.5
100
2B07N, **C07N
2B03F, **C03F
L/min
30
25
20
15
10
5
0
20 40 60 80
100
Command signal (% of max.)Command signal (% of max.)
USgpm
0
1
2
3
4
5
6
7
8
2C28S
2B20N, **C20N
2B13N, **C13N
Performance
Curves
Flow Gain Curves
When using the single
solenoid throttle valves
version (K*FT) a parallel
flowpath module (page 12)
can used to approximately
double the flow rate.
KBF valves are preset at the
factory to compensate for
the effect of spool overlap.
Curves shown include
deadband compensation
provided for the KF valve
by Eaton’s Vickers Eurocard
Amplifier EEA-PAM-533-*-32
(user adjustable).
K(B)FD/TG4V-3
Spool types as noted
Single flowpath (e.g. P–A)
pressure drop, p = 5 bar
(72
psi) .
Frequency Response
(Typical)
where Q
d
= Datum flow rate
p
d
= Pressure drop at datum flow rate
p
x
= Required
p
Q
x
= Q
d
p
x
p
d
At other p values and within the
power capacity envelopes, flow rates
approximate to:
For an amplitude of ± 25%
max. flow about the 50% flow,
at p (P–B) = 5 bar (72 psi)
KBFD/TG4V-3
KFD/TG4V-3
1 2 3 4 5 10
0
+3
3
6
20 30 40
60 80
135°
90°
45°
0
Frequency (Hz)
Phase lag (degrees)
1 2 3 4 5 10
0
+3
3
6
20 30 40
60 80
135°
90°
45°
0
Frequency (Hz)
Amplitude ration (dB)
Amplitude ration (dB)
Phase lag (degrees)
10 EATON Vickers
®
Proportional Valves KBFD/TG4V-3 V-VLPO-MC007-E1 April 2009
Installation
Dimensions
NOTE: For optimum valve
operation, bleed the air from
the proportional solenoids at
initial start-up. This may be
done as follows:
• The valve may be pres-
surized
by removing the
bleed screws until no
bubbles appear and then
reinstalling bleed screws,
or
...
KFDG4V-3
mm (inch)
KFTG4V-3
mm (inch)
Mounting
surface seals supplied
Remove both bleed
screws, and use a stan-
dard
oil can nozzle to
pump fluid in one side
until it flows, free of air
bubbles, out the other
side. Reinstall screws.
If there is no inherent back
pressure in the tank port of
the circuit do not allow the
tank line to empty. This may
be prevented by installing a
check valve in the tank line.
The cracking pressure of the
check valve should be in the
range of 22 - 45 psi (1.5 - 3
bar).
13
(0.52)
clearance
for
removal
Solenoid
plug (ISO 4400/DIN 43650);
gray, marked A, for V models, or
black, marked B, for non-V models;
see 15 in “Model Code”
Solenoid plug (ISO 4400/DIN 43650);
black, marked B, for V models, or
gray, marked A, for non-V models;
see 15 in “Model Code”
3rd angle
projection
11EATON Vickers
®
Proportional Valves KBFD/TG4V-3 V-VLPO-MC007-E1 April 2009
Installation
Dimensions
KBFDG4V-3
mm (inch)
KBFTG4V-3
mm (inch)
Warning
Valves with integral
amplifiers are
supplied with or without the
metal 7-pin plug. The Eaton
plug, part no. 934939, must
be correctly fitted to ensure
that the EMC rating and
IP67 rating are achieved. The
plug retaining nut must be
tightened with a torque of 2,0-
2,5 Nm (1.5-2.0 lbf ft) to effect
a proper seal.
* Bleed screw locations Air
bleed, Socket Head Cap
Screw.
Torque to 2,5-3,0 Nm (2.0-
2.5 lbf ft)
Amplifier and solenoid may
be rotated 90° as shown by
removing 4 screws shown X.
Re-torque to 7-9 Nm (6-7 lbf ft)
12 EATON Vickers
®
Proportional Valves KBFD/TG4V-3 V-VLPO-MC007-E1 April 2009
16
P T
P T
Nameplate
A
A
B
B
(1.97)
65.0
(2.6)
20,0 (0.78)
50.0
(1.9)
47.6
B
A
P
T
4 holes 5,6 (0.22 dia).
counterbored to 9,5 (0.374 dia.)
P T B A
Parallel Path Flow
Module
Subplates and
Mounting Surfaces
General Description
If a subplate is not used,
a machined pad must be
provided for valve mounting.
Pad must be flat within
0,0127 mm (.0005 inch) and
smooth within 1,6 µm (63
microinch). Mounting bolts,
when provided by customer,
should be ISO 898 class
12.9 or better.
Dimensional Tolerances
Dimensional tolerance on
interface drawings is
±0.2
mm (
±0.008”) except where
otherwise stated. ISO 4401
specifies inch conversion to
±0.01”.
Conversion for Metric
ISO 4401 gives dimensions
in mm. Inch conversions are
accurate to 0.01” unless
otherwise stated.
Mounting Bolt Tapping
ISO 4401 gives metric
thread tappings. Alternate
UNC tapping are Eaton’s
recommendations that allow
these plates and associated
valves to be used up to
their maximum pressures,
when using Eaton
recommended bolt kits,
or bolts of an equivalent
strength. It is recommended
Subplates
Description and Mass kg (lb) Functional Symbol Model Code Max. Pressure
Single-station subplate; KDGVM-3-1*-R 250 bar (3600 psi)
rear ports P, T, A, B; side port L KDGVM-3-676803-1*
Cast iron 1,3 (2.9) (SAE/UNF ports
Size 03
Parallel-Flow-Path Module
KDGMA-3-616265-1*
Typically used for doubling effective flow capability
of single solenoid proportional valves (throttle
valves), as illustrated in "Typical Applications'.
A,
TA and TB ports at subplate face are blind
holes fitted with O-seals.
* Design number subject
to change. No change of
installation dimensions
for design numbers 10 to
19 or 21 to 29 inclusive.
“S” suffix = SAE/UNC
ports
and /or UNC
fixing bolt tappings
and/or orifice plugs as
appropriate.
“R” suffix = BSPF and/or
metric fixing bolt tapping
and/or orifice plugs as
appropriate.
that
customer’s own
manifold blocks for UNC
bolts should be tapped to
the minimum depths given
in the footnotes.
13EATON Vickers
®
Proportional Valves KBFD/TG4V-3 V-VLPO-MC007-E1 April 2009
L
25,3
(0.99)
46,5
(1.83)
4,0 (0.16 dia.)
Interface with Additional
Drain Port
ANSI/B93.7M (and NFPA) size
03 CETOP R35H4.2-4-03, plus
location pin hole.
Typically used for proportional
and other valves requiring an
additional drain port.
Installation
Dimensions
Single-Station Subplates
All dimensions in mm (inches)
Port Threads
Ports P, T, A, B
Model Ports P, T, A, B Port L
BSPF ports / M5 mounting bolts:
KDGVM-3-1*-R Rear G 3/8” (3/8” BSPF) x G 1/8” (1/8” BSPF x
12,0 (0.47) deep 12,0 (0.47) deep
SAE ports/#10-24 UNC mounting bolts:
KDGVM-3-676803-1* Rear
3/4”-16 UNF-2B x 14,3 7/16”-20 UNF-2B x
(0.56) deep (SAE) 11,6 (0.46) deep (SAE)
Mounting Surface to ISO
4401 (Size 03)
This interface conforms to:
ISO 4401-03-02-0-05
#10-24 UNC-2B optional
Four holes tapped according to model type (see
table): For models with BSPF ports, M5 x 12 (0.47)
deep. For models with SAE ports, #10.24 UNC-2B x
12,7 (0.5) deep.
4 holes Ø 5,6 (0.22
dia) spotfaced to Ø
13,0 (0.51 dia)
L
P T B A
14 EATON Vickers
®
Proportional Valves KBFD/TG4V-3 V-VLPO-MC007-E1 April 2009
Block Diagram
Voltage Input (M1)
KBFDG
4V-3
KBFDG4V-3 Wiring
Connections must be made
via the 7-pin plug mounted
on the amplifier. See page
15 of this leaflet and Eaton’s
Installation Wiring Practices
for Vickers
®
Electronic
Products, leaflet 2468.
Recommended cable sizes
are:
Power
cables:
For 24V supply 0,75 mm
2
(18 AWG) up to 20m (65 ft)
1,00 mm
2
(16 AWG) up to
40m (130 ft)
Signal cables:
0,50 mm
2
(20 AWG)
Screen (shield):
A suitable cable would have
seven cores, a separate
screen for the signal wires
and an overall screen.
Cable outside diameter 8,0–
10,5 mm (0.31–0.41 inches)
See connection diagram on
next page.
KFDG4V-3 Wiring
Wiring details for these
valves are contained in
the appropriate Eurocard
literature and Eaton’s
Installation Wiring Practices
for Vickers
®
Electronic
Products leaflet 2468.
Electrical
Information
Command Signals and Outputs, M1
7-pin Plug Flow direction
Pin D Pin E
Positive OV
OV Negative P to A
U
d
- U
e
= Positive
Negative OV
OV Positive P to B
U
d
- U
e
= Negative
WARNING
All power must
be switched off
before connecting/discon-
necting
any plugs.
Of fset
Modulator
Valve envelope
7-pin plug connections
+24V
A
B
D
E
F
G
P
ower 0V
Enable or
n
ot connected
Protective
ground
Non-inverting
Inverting
Command
signal
voltage,
see table
Compensation
network
+15V
0V
15V
+24V
L
VDT
C
Monitor output
Gain
+24V
Solenoid
drive
Pin C is used for a valve enable signal with electrical connections PH7 and PR7.
15EATON Vickers
®
Proportional Valves KBFD/TG4V-3 V-VLPO-MC007-E1 April 2009
Electrical
Information
Block Diagram
Current Input (M2)
KFSDG4V-3
KBSDG4V-3 Wiring
Connections must be made
via the 7-pin plug mounted
on the amplifier. See page
15 of this leaflet and Eaton’s
Installation Wiring Practices
for Vickers® Electronic
Products, leaflet 2468.
Recommended cable sizes
are:
Power
cables:
For 24V supply
0,75 mm2 (18 AWG) up to
20m (65 ft) 1,00 mm2 (16
AWG) up to 40m (130 ft)
Signal cables:
0,50 mm2 (20 AWG)
Screen (shield):
A suitable cable would have
seven cores, a separate
screen for the signal wires
and an overall screen.
Cable outside diameter 8,0–
10,5 mm (0.31–0.41 inches)
See connection diagram on
next page.
KFDG4V-3 Wiring
Wiring details for these
valves are contained in the
appropriate Eurocard literature
and Eaton’s Installation
Wiring Practices for Vickers®
Electronic Products leaflet
2468.
Command Signals and Outputs, M2
7-pin plug
Pin D Pin E Pin B Flow direction
More than Current Power
12 mA return ground P to A
Less than Current Power
12
mA return ground P to B
WARNING
All power must
be switched off
before connecting/discon-
necting
any plugs.
Offset
Modulator
Valve envelope
7-pin plug connections
+24V
A
B
D
E
F
G
P
ower 0V
Enable or
not connected
Protective ground
Command +4 to 20 mA
Compensation
network
+15V
0V
-15V
+24V
LVDT
C
Monitor output
+24V
Solenoid
drive
Gain
F1
R1
F2
Return
Pin C is used for a valve enable signal with electrical connections PH7 and PR7.
R1 shunt resistor 100R
F1, F2 resettable fuse
16 EATON Vickers
®
Proportional Valves KBFD/TG4V-3 V-VLPO-MC007-E1 April 2009
Electrical
Information
Wiring Connections
Voltage Input (M1)
Spool position monitor
voltage (pin F) will be
referenced to the KB valve
local ground.
WARNING
Do not ground
pin C.
Wiring Connections for
M1 Valves with Enable
Feature
Note: In applications
where the valve must
conform to European
RFI/EMC regulations, the
outer screen (shield) must
be connected to the outer
shell of the 7-pin connector,
and the valve body must
be fastened to the earth
ground. Proper earth
grounding practices must
be observed in this case, as
any differences in command
source and valve ground
potentials will result in a
screen (shield) ground loop.
Input
User Panel
P
ower
Supply
Demand
Signal
Spool
P
osition
Monitor
0
V must be
connected to ground
Enclosure
+24V
0V
±10V
Connector
shell
O
uter Screen
KB..PC7/PE7 valve
A
B
D or E
0V
0V
C
Drain Wire
Inner Screen
G
F
Valve
must be
connected
to ground
via
subplate
0V
Input
User Panel
P
ower
Supply
Demand
Signal
Spool
Position
Monitor
+24V
±10V
Connector
shell
O
uter Screen
A
B
D
or E
0V
0V
C
Drain Wire
Inner Screen
E or D
G
F
KB..PR7/PH7 valve
Enable
Signal
+8.5V
t
o 36V
0V
Enclosure
Valve
must be
connected
to ground
via
subplate
0V must be
connected to ground
17EATON Vickers
®
Proportional Valves KBFD/TG4V-3 V-VLPO-MC007-E1 April 2009
Electrical
Information
Wiring Connections
Current Input (M2)
Spool position monitor
voltage (pin F) will be
referenced to the KB valve
local ground.
WARNING
Do not ground
pin C.
Wiring Connections for
M2 Valves with Enable
Feature
Note: In applications
where
the valve must
conform to European
RFI/EMC regulations, the
outer screen (shield) must
be connected to the outer
shell of the 7-pin connector,
and the valve body must
be fastened to the earth
ground. Proper earth
grounding practices must
be observed in this case, as
any differences in command
source and valve ground
potentials will result in a
screen (shield) ground loop.
WARNING
Electromagnetic
Compatibility
(EMC)
It is necessary to ensure
that the valve is wired up
as above. For effective
protection the user electrical
cabinet, the valve subplate
or manifold and the cable
screens should be connected
to efficient ground points.
The metal 7-pin connector
part no. 934939 should
be used for the integral
amplifier. In all cases both
valve and cable should be
kept as far away as possible
from any sources of elec-
tromagnetic
radiation such
as cables carrying heavy
current, relays and certain
kinds of portable radio
transmitters, etc. Difficult
environments could mean
that extra screening may
be necessary to avoid the
interference.
It
is important to connect
the 0V lines as shown
above. The multi-core cable
should have at least two
screens to separate the
Input
User Panel
Power
Supply
Demand
Signal
Spool
P
osition
Monitor
0
V must be
connected to ground
Enclosure
+24V
4 - 20 mA
0V
Valve
must be
connected
to ground
via
subplate
Connector
shell
O
uter Screen
KB..PC7/PE7 valve
A
B
E
0V
0V
C
Drain Wire
Inner Screen
G
F
D
0V
Input
User Panel
Power
Supply
Demand
Signal
Spool
P
osition
Monitor
+24V
Connector
shell
4 - 20 mA
O
uter Screen
A
B
E
0V
0V
C
Drain Wire
Inner Screen
D
G
F
KB..PR7/PH7 valve
0V must be
connected to ground
Enable
Signal
+8.5V
t
o 36V
0V
Enclosure
Valve
must be
connected
to ground
via
subplate
demand signal and monitor
output from the power
lines.
The
enable line to pin C
should be outside the
screen which contains the
demand signal cables.
18 EATON Vickers
®
Proportional Valves KBFD/TG4V-3 V-VLPO-MC007-E1 April 2009
Application Data
Fluid Cleanliness
Proper fluid condition is essential for long and satisfactory
life of hydraulic components and systems. Hydraulic fluid
must have the correct balance of cleanliness, materials
and additives for protection against wear of components,
elevated viscosity and inclusion of air.
Recommendations on contamination control methods
and the selection of products to control fluid condition
are included in Eaton’s publication 9132 or 561, “Vickers
Guide to Systemic Contamination Control”. The book also
includes information on the Eaton’s concept of “ProActive
Maintenance”.
The
following recommendations are based on ISO
cleanliness levels at 2 µm, 5 µm and 15 µm:
For
products in this catalog the recommended levels are:
0 to 70 bar (1000 psi) . . . . . . . . . . . . . . 18/16/13
70
+ bar (1000 + psi) . . . . . . . . . . . . . . . 17/15/12
Eaton
products, as any components, will operate with
apparent satisfaction in fluids with higher cleanliness codes
than those described. Other manufacturers will often
recommend levels above those specified.
Experience has shown, however, that life of any hydraulic
components is shortened in fluids with higher cleanliness
codes than those listed above. These codes have been
proven to provide a long trouble-free service life for the
products shown, regardless of the manufacturer.
Hydraulic Fluids
Materials and seals used in these valves are compatible
with antiwear hydraulic oils, and non-alkyl-based phosphate
esters. The extreme operating viscosity range is 500 to
13
cSt (2270 to 70 SUS) but the recommended running
range is 54 to 13 cSt (245 to 70 SUS).
Installation
The proportional valves in this catalog can be mounted in
any attitude, but it may be necessary in certain demanding
applications, to ensure that the solenoids are kept full
of hydraulic fluid. Good installation practice dictates that
the tank port and any drain port are piped so as to keep
the valves full of fluid once the system start-up has been
completed.
Mounting Bolt Kits
For K(B)FD/TG4V-3
BK02-156493M (metric)
BK590716(inch)
If not using Eaton recommended bolt kits, bolts used should be to ISO 898, 12.9 or better.
Seal Kits
KFD/TG4V-3 . . . . . . . . . . . . . . . . . . . . . . .565108
KBFD/TG4V-3-1* . . . . . . . . . . . . . . . . 02-332693
Plugs
KBFDG4V
7-pin plug (metal) . . . . . . . . . . . . . . . . . . .934939
7-pin
plug (plastic). . . . . . . . . . . . . . . . . . .694534
(metal
plug must be used for full EMC protection)
NOTE: An alternative metal connector which gives EMC
protection
but not IP67 rating is available from ITT-Cannon,
part number CA06-COM-E-14S-A7-S.
KFDG4V
Solenoid
(black) . . . . . . . . . . . . . . . . . . . .710775
Solenoid
(gray) . . . . . . . . . . . . . . . . . . . . .710776
L
VDT (gray) . . . . . . . . . . . . . . . . . . . . . . . . 458939
Extension Cable
Extension Cable: Adapter for extending seven core cable
when changing from KA to KB valve and existing wiring is
not long enough. Consists of a 7-pin plug, a 7-pin socket
and a length of cable, fully assembled for ease of use.
Extension Cable . . . . . . . . . . . . . . . . . . . .944450
Service Information
The products from this range are preset at the factory for
optimum performance; disassembling critical items would
destroy these settings. It is therefore recommended that
should any mechanical or electronic repair be necessary
they should be returned to the nearest Eaton repair center.
The products will be refurbished as necessary and retested
to specification before return.
Field repair is restricted to the replacement of the seals.
NOTE: The
feedback/solenoid assembly installed in this
valve should not be disassembled.
19EATON Vickers
®
Proportional Valves KBFD/TG4V-3 V-VLPO-MC007-E1 April 2009
Eaton
Hydraulics Group USA
14615 Lone Oak Road
Eden Prairie, MN 55344
USA
Tel: 952-937-9800
Fax: 952-294-7722
www.eaton.com/hydraulics
Eaton
Hydraulics Group Europe
Route de la Longeraie 7
1110 Morges
Switzerland
Tel: +41 (0) 21 811 4600
Fax: +41 (0) 21 811 4601
Eaton
Hydraulics Group Asia Pacific
11th Floor Hong Kong New World Tower
300 Huaihai Zhong Road
Shanghai 200021
China
Tel: 86-21-6387-9988
Fax: 86-21-6335-3912
© 2009 Eaton Corporation
All Rights Reserved
Printed in USA
Document No. V-VLPO-MC007-E1
April 2009