Servo-Performance Proportional
Directional Valves with Feedback
Pressures to 350 bar (5075 psi)
K(B)SDG4V-3
1* Series
V-VLPO-MC005-E_080826.qxd 27-08-2008 1:02 Pagina 1
2 EATON Vickers Proportional Directional Valves with Feedback K(B)SDG4V-3, V-VLPO-MC005-E August 2008
Contents
Introduction
General Description 3
KSDG4V-3 Features and Benefits 3
KBSDG4V-3 Features and Benefits 3
Typical Section View 3
Model Code 4
Spool Data 5
Functional Symbol 5
Operating Data 6
Pressures and Flow Rates 7
Performance Curves
Flow Gain 8
Pressure Gain 8
Power Capacity Envelopes 8
Frequency Response 9
Installation Dimension KSDG4V-3 10
Installation Dimension KBSDG4V-3 10
Subplates and Mounting Surface Interfaces 11
Electrical Information
Block Diagram Voltage Input M1 13
Block Diagram Current Input M2 14
Typical Connection Arrangements M1 15
Typical Connection Arrangements M2 16
Application Data
Fluid Cleanliness 17
Hydraulic Fluids 17
Installation 17
Mounting Bolt Kits 17
Seal Kits 17
Electrical Connectors 17
Service Information 17
V-VLPO-MC005-E_080826.qxd 27-08-2008 1:02 Pagina 2
3EATON Vickers Proportional Directional Valves with Feedback K(B)SDG4V-3, V-VLPO-MC005-E August 2008
Introduction
General Description
The KBSDG4V-3 line offers a
range of proportional
directional valves with
integral control electronics.
Factory-set adjustments of
gain and offset ensure
consistent reproducibility
valve-to-valve.
These four-way solenoid
operated proportional valves
have a high dynamic
performance which enables
them to be used in closed-
loop applications, previously
possible only with servo
valves. Various spool options
are available for rated flows
up to 40 L/min (10.6
USgpm). Working pressures
are to 350 bar (5000 psi). The
spool position is monitored
by an LVDT which feeds back
information to the amplifier,
enabling spool position to be
accurately maintained.
This valve type can be
supplied with or without an
integral amplifier built
directly onto the valve.
KSDG4V-3
Without the integral amplifier.
Features and Benefits
Wide range of spool and
flow rate options.
Supported by a broad
range of amplifiers and
auxiliary function modules.
Electronic feedback LVDT
ensures accurate spool
position control.
Internal current feedback
provides optimal control.
Vibration and shock
tested.
Full CE electromagnetic
compatibility.
KBSDG4V-3
With integral control
electronics.
Factory-set adjustments of
gain and offset ensure
consistent repeatability
valve-to-valve.
The only electrical inputs
required are power supply
(24V) and a command signal,
either ±10V or 4-20 mA
(model code selectable). The
amplifier is housed in a
robust metal enclosure,
sealed against ingress of
water and other fluids.
Electrical connections are via
a standard 7-pin plug.
A spool position monitor pin
allows the function of the
valve to be electrically
monitored. Ramp functions,
if required, can be generated
externally.
Features and Benefits
Factory-sealed
adjustments ensure valve-
to-valve reproducibility.
Installation wiring reduced
and simplified.
Standard 7-pin connector.
Standard 24V DC supply
with wide tolerance band.
Optional command signal,
±10V or 4-20 mA (model
code selectable).
Valve with integrated
amplifier selected,
ordered, delivered and
installed as one
performance-tested
package.
Spool position monitor pin
to help with
troubleshooting.
Simple valve removal and
replacement for service
(plug & play).
Vibration and shock
tested.
Auxiliary DIN rail mounted
electronic function
modules available.
Full CE electromagnetic
compatibility.
IP67 valve, environmental
protection rating.
Optional valve enable
function.
Typical Section View
KBSDG4V-3
V-VLPO-MC005-E_080826.qxd 27-08-2008 1:02 Pagina 3
4 EATON Vickers Proportional Directional Valves with Feedback K(B)SDG4V-3, V-VLPO-MC005-E August 2008
Model Code
Va l v e type
K
– Proportional valve
I n t e g ral amplifier
B Integral amplifier “B”
series
Omit for models without
integrated amplifiers.
Feed back arra n g e m e n t
S
– Closed-loop
C o n t r ol type
D
– Directional valve
M o u n t i n g
G
– Subplate mounted
O p e r a t i o n
4
– Solenoid operated
P r e s s u re ra t i n g
V
– >250 bar (3625 psi) on
ports P,A, & B
I n t e r fa c e
3
– ISO 4401, size 03-02-0-94
ANSI/B93.7M-D03
Spool type
( c e n t er condition)
9
– Zero lap (biased underlap)
Spool type, s p ring off s e t
c o n d i t i o n
2
– Ports P, A, & T blocked
6
– Port P blocked, A & B to
tank
Va l v e build
L
– Standard build
R a t ed flow at 70 bar
( 1000 psi) loop p pre s s u re
d ro p
05
– 5 L/min (1.3 USgpm)
12
– 12 L/min (3.2 USgpm)
24
– 24 L/min (6.3 USgpm)
40
– 40 L/min (10.6 USgpm)
For actual maximum flow refer
to Power capacity envelope
curves, page 8.
LVDT plug
(omit for valves with integral
amplifier)
M1
– ±10V voltage command
signal
M2
– 4-20 mA current
command signal
Solenoid connecto r
(omit for valves with integral
amplifier)
U1
– ISO 4400/DIN 43650,
non-integral amplifier type only
(mating plugs supplied)
E l e c t rical connection
(KBS va l ves only)
PC7
– 7 pin connector without
plug
PE7
– 7 pin electrical plug
with mating half
PH7
– As PE7 but with pin
“C” used for enable signal
PR7
– As PC7 but with pin
“C” used for enable signal
Coil ra t i n g
H
– 24V DC amplifier supply
Po rt T pre s s u re limit code
7
– For all spools
Design number
1* series. Subject to change
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
WARNING
Valves with integral
amplifiers are
supplied with or without the
metal 7-pin plug.
The Vickers™ plug, part
no. 934939, must be
correctly fitted to ensure that
the EMC rating and IP67
rating are achieved. The plug
retaining nut must be
tightened with a torque of
2-2,0 Nm (1.5-2.5 lbf ft) to
effect a proper seal.
V-VLPO-MC005-E_080826.qxd 27-08-2008 1:02 Pagina 4
5EATON Vickers Proportional Directional Valves with Feedback K(B)SDG4V-3, V-VLPO-MC005-E August 2008
Spool Data
Spool Symbols
Spool code Spool symbol Flow rating
For K(B)SDG4V-3 valves:
92L05 92L 5 L/min (1.3 USgpm)
92L12 92L 12 L/min (3.2 USgpm)
92L24 92L 24 L/min (6.3 USgpm)
92L40 92L 40 L/min (10.6 USgpm)
96L05 96L 5 L/min (1.3 USgpm)
96L12 96L 12 L/min (3.2 USgpm)
96L24 96L 24 L/min (6.3 USgpm)
96L40 96L 40 L/min (10.6 USgpm)
Spool Types and Flow
Ratings
Symmetric Spools
Base line starting at
p = 35 bar (500 psi)
per metering flow path,
e.g. B to T. For actual
maximum flow refer to
power capacity envelope
curves.
Available Spools for K(B)SDG4V-3
Spool type 92L Spool type 96L
Functional Symbol
Model Types KBSDG4V-3
proportional directional valve (with integral electronics)
Model Types KSDG4V-3
proportional directional valve (requires amplifier card)
V-VLPO-MC005-E_080826.qxd 27-08-2008 1:02 Pagina 5
Operating Data
KBSDG4V-3 Valves with integral amplifier: Data is typical, with fluid at 36 cSt (168 SUS) and 50°C (122°F).
Power supply 24V DC (21V to 36V including 10% peak-to-peak max. ripple)
max current 3A
Command signal
Voltage mode 0 to 10V DC, or 0 to –10V DC, or –10V to + 10V DC
Input impedance M1: 47 kΩ - M2: 100R
Common mode voltage to pin D 18V (max)
Current mode 4-20 mA
Max differential voltage to pin E to pin B 100 mV
Valve enable signal for model code PH7
Enable >8.5V (36V max)
Disable <6.5V
Input impedance 10 kΩ
7-pin plug connector Pin Description
A Power supply positive (+)
B Power supply 0V and current command return
C Not connected (PE7 & PC7)
C Valve enable (PH7 & PR7)
D Command signal (+V or current in)
E Command signal (-V or current GND)
F Output monitor
G Protective ground
View of pins of fixed half.
Electromagnetic compatibility (EMC): IEC61326-2-1
Zero adjustment ±18% mechanical adjustment accessible under plug
in LVDT
Monitor points signal
Voltage mode ±10V DC for full stroke
Output impedance 10 kΩ
Power stage PWM frequency 10 kHz nominal
Reproducibility, valve-to-valve (at factory settings):
Flow gain at 100% command signal 5%
Protection:
Electrical Reverse polarity protected
Mechanical IEC 144, Class IP67
Relative humidity 85 to 95% at 20 to 70°C (68 to 158°F)
Ambient air temperature range for full performance 0°C to 70°C (32°F to 158°F)
Oil temperature range for full performance 0°C to 70°C (32°F to 158°F)
Minimum temperature at which valves will
work at reduced performance –20°C (–4°F)
Storage temperature range –25°C to +85°C (–13°F to +185°F)
Supporting products:
Auxiliary electronic modules (DIN-rail mounting):
EHA-CON-201-A2* signal converter See catalog GB 2410A
EHD-DSG-201-A-1* command signal generator See catalog GB 2470
EHA-RMP-201-A-2* ramp generator See catalog GB 2410A
EHA-PID-201-A-2* PID controller See catalog GB 2427
EHA-PSU-201-A-10 power supply See catalog GB 2410A
V-VLPO-MC005-E_080826.qxd 27-08-2008 1:02 Pagina 6
7EATON Vickers Proportional Directional Valves with Feedback K(B)SDG4V-3, V-VLPO-MC005-E August 2008
Operating Data
KSDG4V-3 Valves without integral amplifier (requires a Eurocard amplifier, refer to Supporting Products)
Standing current at null 1,7A
Max current, at 50°C (122°F) ambient 3,2A
Coil resistance, at 20°C (68°F) 1,87Ω
Coil inductance, at 1000 Hz & 150 mV 7.2 mH
Max solenoid power 30W
LVDT supply voltage +15V DC
LVDT output signal 4 to 20 mA for spool stroke of 2,1 mm
Electromagnetic compatibility (EMC) IEC61326-2-1
Base amplifier EEA-PAM-553-A-3*
Power requirements: 20 to 40V DC at 40W
Mechanical protection IEC 144, Class IP65
Maximum allowable ambient air temperature 60°C (140°F)
Maximum allowable oil temperature 60°C (140°F)
KSDG4V-3 and KBSDG4V3 Valves (all valves)
Relative duty factor Continuous rating (ED = 100%)
Hysteresis <0.5%
Step response:
Step size (% of max spool stroke): Time to reach 90% of required step:
0-100% or 100-0% 10 mS
10-90% or 90-10% 6 mS
±10% to ±10% 4 mS
±25% to ±25% 5 mS
10-90% 6 mS
Mass:
KSDG4V-3 2,09 kg (4.6 lb) approx.
KBSDG4V-3 2,49 kg (5.5 lb) approx.
Pressures and Flow
Rates
Maximum pressures, bar
(psi)
Port L condition Ports P, A, B T L
Normally blocked by mounting surface 350 (5000) 50 (720) 50 (720)
Drained directly to tank 350 (5000) 210 (3000) 10 (145)
V-VLPO-MC005-E_080826.qxd 27-08-2008 1:02 Pagina 7
Flow Gain
Flow from port P-A-B-T or P-B-A-T at 70 bar (1000 psi) total
valve p, 35 bar (500 psi) per metering edge
8 EATON Vickers Proportional Directional Valves with Feedback K(B)SDG4V-3, V-VLPO-MC005-E August 2008
Performance
Curves
Pressure Gain
p between ports A and B or B and A, as % of port P
pressure
Spool stroke from
null, % of max.
Power Capacity Envelopes
K(B)SDG4V-3-9*L-05 Valves K(B)SDG4V-3-9*L-12 Valves
V-VLPO-MC005-E_080826.qxd 27-08-2008 1:02 Pagina 8
9EATON Vickers Proportional Directional Valves with Feedback K(B)SDG4V-3, V-VLPO-MC005-E August 2008
Performance
Curves
Frequency Response, typical
For amplitudes of ±5%, ±10, ±25% with zero offset.
p (P to T) = 70 bar (1000 psi)
K(B)SDG4V-3-9*L-24 Valves K(B)SDG4V-3-9*L-40 Valves
Power Capacity Envelopes
Frequency Response
Looped flow at 70 bar valve pressure drop
Amplitudes based on % of rated flow
V-VLPO-MC005-E_080826.qxd 27-08-2008 1:02 Pagina 9
10 EATON Vickers Proportional Directional Valves with Feedback K(B)SDG4V-3, V-VLPO-MC005-E August 2008
Installation
Dimensions
KSDG4V-3
KBSDG4V-3
Mounting surface seals supplied.
For mounting surface dimensions and subplate options
see page 11.
Bleed screw location
Air bleed, socket head cap screw
Torque to 2,5-3,0 Nm (2.0-2.5 lbf ft )
WARNING
Valves with integral
amplifiers are
supplied with or without the
metal 7-pin plug. The
Vickers™ plug, part
no. 934939, must be
correctly fitted to ensure that
the EMC rating and IP67
rating are achieved. The plug
retaining nut must be
tightened with a torque of
2-2,5 Nm (1.5-2.0 lbf ft) to
effect a proper seal.
V-VLPO-MC005-E_080826.qxd 27-08-2008 1:03 Pagina 10
11EATON Vickers Proportional Directional Valves with Feedback K(B)SDG4V-3, V-VLPO-MC005-E August 2008
Subplates and
Mounting
Surfaces
General Description
If a subplate is not used, a
machined pad must be
provided for valve mounting.
Pad must be flat within
0,0127 mm (.0005 inch) and
smooth within 1,6 µm (63
microinch). Mounting bolts,
when provided by customer,
should be ISO 898 class 12.9
or better.
Dimensional Tolerances
Dimensional tolerance on
interface drawings is
±0,2 mm (±0.008”) except
where otherwise stated. ISO
4401 specifies inch
conversion to ±0.01”.
Conversion from Metric
ISO 4401 gives dimensions
in mm. Inch conversions are
accurate to 0.01” unless
otherwise stated.
Mounting Bolt Tappings
ISO 4401 gives metric thread
tappings. Alternate UNC
tappings are Eaton
recommendations that allow
these plates and associated
valves to be used up to their
maximum pressures, when
using Eaton recommended
bolt kits, or bolts of an
equivalent strength. It is
recommended that
Customer’s own manifold
blocks for UNC bolts should
be tapped to the minimum
depths given in the
footnotes.
Installation Dimensions
Single-Station Subplates,
Rear and Side Tapped Ports
Port Threads Model Ports P, T, A, B, at rear or side Port L
BSPF ports/M5 mounting bolts
KDGVM-3-1*-R Rear G3/8 (3/8” BSPF) x 12,0 (0.47) deep G1/8 (1/8” BSPF) x 12,0 (0.47) deep
SAE ports/#10-24 UNC mounting bolts:
KDGVM-3-676803-1* Rear 3/4”-16 UNF-2Bx14,3 (0.56) deep (SAE) 7/16” -20 UNF-2B x 11,6 (0.46) deep (SAE)
Subplates
Description and Mass kg (lb) Functional Symbol Model Code Max. Pressure
Single-station subplate; KDGVM-3-1*-R
250 bar (3600 psi)
rear ports P, T, A, B; side port L KDGVM-3-676803-1*
Cast iron 1,3 (2.9) (SAE/UNF ports)
* Design number subject to change. No change of installation dimensions for design numbers 10 to 19 or 21 to 29 inclusive.
“S” suffix = SAE/UNC ports and/or UNC fixing bolt tappings and/or orifice plugs as appropriate.
“R” or “B” = ISO 228 (BSPF) ports and/or metric fixing bolt tappings and/or orifice plugs as appropriate.
V-VLPO-MC005-E_080826.qxd 27-08-2008 1:03 Pagina 11
12 EATON Vickers Proportional Directional Valves with Feedback K(B)SDG4V-3, V-VLPO-MC005-E August 2008
Mounting
Surfaces
Mounting Surfaces to ISO
401 (Size 03)
This interface conforms to:
ISO 4401-03-02-0-94
plus location pin hole
ANSI/B93.7M (and NFPA)
size 03
CETOP R35H4.2-4-03, plus
location pin hole
DIN 24340 Form A6 plus
location pin hole
Interface with Additional
Drain Port
The interface conforms to
Eaton standard, plus hole
“L
Typically used for
proportional and other valves
requiring an additional drain
port.
V-VLPO-MC005-E_080826.qxd 27-08-2008 1:03 Pagina 12
13EATON Vickers Proportional Directional Valves with Feedback K(B)SDG4V-3, V-VLPO-MC005-E August 2008
Electrical
Information
Pin C is used for a valve enable signal with electrical connections PH7 and PR7.
Command Signals and Outputs, M1
7-pin plug Flow direction
Pin D Pin E
Positive OV
P to AOV Negative
U
D
- U
E
= Positive
Negative OV
P to BOV Positive
U
D
- U
E
= Negative
Block Diagram
Voltage Input (M1)
KBSDG4V-3
WARNING
All power must be
switched off before
connecting/disconnecting
any plugs.
KBSDG4V-3 Wiring
Connections must be made
via the 7-pin plug mounted
on the amplifier. See page
15 of this leaflet and Eatons
Installation Wiring Practices
for Vickers™ Electronic
Products, leaflet 2468.
Recommended cable sizes
are:
Power cables:
For 24V supply
0,75 mm
2
(18 AWG) up to
20m (65 ft)
1,00 mm
2
(16 AWG) up to
40m (130 ft)
Signal cables:
0,50 mm
2
(20 AWG)
Screen (shield):
A suitable cable would have
7 cores, a separate screen
for the signal wires and an
overall screen.
Cable outside diameter
8,0–10,5 mm (0.31–0.41
inches)
See connection diagram on
next page.
KSDG4V-3 Wiring
Wiring details for these
valves are contained in the
appropriate Eurocard
literature and Eatons
Installation Wiring Practices
for Vickers™ Electronic
Products leaflet 2468.
V-VLPO-MC005-E_080826.qxd 27-08-2008 1:03 Pagina 13
14 EATON Vickers Proportional Directional Valves with Feedback K(B)SDG4V-3, V-VLPO-MC005-E August 2008
KBSDG4V-3 Wiring
Connections must be made
via the 7-pin plug mounted
on the amplifier. See page
15 of this leaflet and Eatons
Installation Wiring Practices
for Vickers™ Electronic
Products, leaflet 2468.
Recommended cable sizes
are:
Power cables:
For 24V supply
0,75 mm
2
(18 AWG) up to
20m (65 ft)
1,00 mm
2
(16 AWG) up to
40m (130 ft)
Signal cables:
0,50 mm
2
(20 AWG)
Screen (shield):
A suitable cable would have
7 cores, a separate screen
for the signal wires and an
overall screen.
Cable outside diameter
8,0–10,5 mm (0.31–0.41
inches)
See connection diagram on
next page.
KSDG4V-3 Wiring
Wiring details for these
valves are contained in the
appropriate Eurocard
literature and Eatons
Installation Wiring Practices
for Vickers™ Electronic
Products leaflet 2468.
WARNING
All power must be
switched off before
connecting/disconnecting
any plugs.
Electrical
Information
Pin C is used for a valve enable signal with electrical connections PH7 and PR7.
R1 shunt resistor 100R
F1, F2 resettable fuse
Command Signals and Outputs, M2
7-pin plug
Pin D Pin E Pin B Flow direction
More than Current Power
12 mA return ground P to A
Less than Current Power
12 mA return ground P to B
Block Diagram
Current Input (M2)
KBSDG4V-3
V-VLPO-MC005-E_080826.qxd 27-08-2008 1:03 Pagina 14
15EATON Vickers Proportional Directional Valves with Feedback K(B)SDG4V-3, V-VLPO-MC005-E August 2008
Electrical
Information
Wiring Connections
Voltage Input (M1)
Spool position monitor
voltage (pin F) will be
referenced to the KB valve
local ground.
WARNING
Do not ground pin C.
Wiring Connections for M1
Valves with Enable Feature
Note: In applications
where the valve must
conform to European
RFI/EMC regulations, the
outer screen (shield) must
be connected to the outer
shell of the 7 pin connector,
and the valve body must be
fastened to the earth ground.
Proper earth grounding
practices must be observed
in this case, as any
differences in command
source and valve ground
potentials will result in a
screen (shield) ground loop.
V-VLPO-MC005-E_080826.qxd 27-08-2008 1:03 Pagina 15
16 EATON Vickers Proportional Directional Valves with Feedback K(B)SDG4V-3, V-VLPO-MC005-E August 2008
Electrical
Information
Wiring Connections
Current Input (M2)
Spool position monitor
voltage (pin F) will be
referenced to the KB valve
local ground.
WARNING
Do not ground pin C.
Wiring Connections for M2
Valves with Enable Feature
Note: In applications
where the valve must
conform to European
RFI/EMC regulations, the
outer screen (shield) must
be connected to the outer
shell of the 7 pin connector,
and the valve body must be
fastened to the earth ground.
Proper earth grounding
practices must be observed
in this case, as any
differences in command
source and valve ground
potentials will result in a
screen (shield) ground loop.
WARNING
Electromagnetic
Compatibility (EMC)
It is necessary to ensure that
the valve is wired up as
above. For effective
protection the user electrical
cabinet, the valve subplate or
manifold and the cable
screens should be
connected to efficient
ground points. The metal 7
pin connector part no.
934939 should be used fo r
the integral amplifier.
In all cases both valve and
cable should be kept as far
away as possible from any
sources of electromagnetic
radiation such as cables
carrying heavy current, relays
and certain kinds of portable
radio transmitters, etc.
Difficult environments could
mean that extra screening
may be necessary to avoid
the interference.
It is important to connect the
0V lines as shown above.
The multi-core cable should
have at least two screens to
separate the demand signal
and monitor output from the
power lines.
The enable line to pin C
should be outside the screen
which contains the demand
signal cables.
V-VLPO-MC005-E_080826.qxd 27-08-2008 1:03 Pagina 16
17EATON Vickers Proportional Directional Valves with Feedback K(B)SDG4V-3, V-VLPO-MC005-E August 2008
Application
Data
Fluid Cleanliness
Proper fluid condition is
essential for long and
satisfactory life of hydraulic
components and systems.
Hydraulic fluid must have the
correct balance of
cleanliness, materials and
additives for protection
against wear of components,
elevated viscosity and
inclusion of air.
Recommendations on
contamination control
methods and the selection of
products to control fluid
condition are included in
Eatons publication 9132 or
561, “Vickers™ Guide to
Systemic Contamination
Control”. The book also
includes information on the
Eaton concept of “ProActive
Maintenance. The following
recommendations are based
on ISO cleanliness levels at 2
µm, 5 µm and 15 µm.
For products in this catalog
the recommended levels are:
0 to 70 bar (1000 psi):
18/16/13
70+ bar (1000 + psi):
17/15/12
Eaton products, as any
components, will operate
with apparent satisfaction in
fluids with higher cleanliness
codes than those described.
Other manufacturers will
often recommend levels
above those specified.
Experience has shown,
however, that life of any
hydraulic components is
shortened in fluids with
higher cleanliness codes
than those listed above.
These codes have been
proven to provide a long
trouble-free service life for
the products shown,
regardless of the
manufacturer.
Hydraulic Fluids
Materials and seals used in
these valves are compatible
with antiwear hydraulic oils,
and non-alkyl-based
phosphate esters. The
extreme operating viscosity
range is 500 to 13 cSt (2270
to 70 SUS) but the
recommended running range
is 54 to 13 cSt (245 to 70
SUS).
Installation
The proportional valves in
this catalog can be mounted
in any attitude, but it may be
necessary in certain
demanding applications, to
ensure that the solenoids are
kept full of hy
draulic fluid.
Good installation practice
dictates that the tank port
and any drain port are piped
so as to keep the valves full
of fluid once the system
start-up has been completed.
Mounting Bolt Kits
For K(B)SDG4V-3
BK02-156493M (metric)
BK590716 (inch)
If not using Eaton
recommended bolt kits,
bolts used should be to
ISO 898, 12.9 or better.
Seal Kits
KSDG4V-3-1* .............565108
KBSDG4V-3-1* .....02-332693
Electrical Connectors
KBSDG4V
7-pin plug (metal).......934939
7-pin plug (plastic)......694534
(metal plug must be used for
full EMC protection)
KSDG4V
Solenoid (gray) ...........710776
LVDT (gray) ................458939
Service Information
The products from this range
are preset at the factory for
optimum performance;
disassembling critical items
would destroy these
settings. It is therefore
recommended that should
any mechanical or electronic
repair be necessary they
should be returned to the
nearest Eaton repair center.
The products will be
refurbished as necessary and
retested to specification
before return.
Field repair is restricted to
the replacement of the seals.
Note:
The feedback/solenoid
assembly installed in this
valve should not be
disassembled.
Typical Part Numbers and Model Codes
5996404-001 KBSDG4V-3-92L-05-M1-PC7-H7-11 5996420-001 KBSDG4V-3-92L-40-M2-PE7-H7-11
5996398-001 KBSDG4V-3-92L-05-M1-PE7-H7-11 5996414-001 KBSDG4V-3-96L-05-M1-PC7-H7-11
5996399-001 KBSDG4V-3-92L-05-M1-PH7-H7-11 5996410-001 KBSDG4V-3-96L-05-M1-PE7-H7-11
5996405-001 KBSDG4V-3-92L-12-M1-PC7-H7-11 5996415-001 KBSDG4V-3-96L-12-M1-PE7-H7-11
5996400-001 KBSDG4V-3-92L-12-M1-PE7-H7-11 5996416-001 KBSDG4V-3-96L-12-M2-PE7-H7-11
5996401-001 KBSDG4V-3-92L-12-M1-PH7-H7-11 5996423-001 KBSDG4V-3-96L-12-M2-PE7-H7-11
5996406-001 KBSDG4V-3-92L-24-M1-PC7-H7-11 5996417-001 KBSDG4V-3-96L-24-M1-PC7-H7-11
5996402-001 KBSDG4V-3-92L-24-M1-PE7-H7-11 5996411-001 KBSDG4V-3-96L-24-M1-PE7-H7-11
5996407-001 KBSDG4V-3-92L-24-M1-PH7-H7-11 5996418-001 KBSDG4V-3-96L-40-M1-PC7-H7-11
5996421-001 KBSDG4V-3-92L-24-M2-PC7-H7-11 5996412-001 KBSDG4V-3-96L-40-M1-PE7-H7-11
5996408-001 KBSDG4V-3-92L-40-M1-PC7-H7-11 5996413-001 KBSDG4V-3-96L-40-M1-PH7-H7-11
5996403-001 KBSDG4V-3-92L-40-M1-PE7-H7-11 5996422-001 KBSDG4V-3-96L-40-M2-PE7-H7-11
5996409-001 KBSDG4V-3-92L-40-M1-PH7-H7-11
V-VLPO-MC005-E_080826.qxd 27-08-2008 1:03 Pagina 17
© 2007 Eaton Corporation
All Rights Reserved
Printed in USA
Document No. V-VLPO-MC005-E
Supersedes 5071.02/EN/0298/A
August 2008
Eaton
Hydraulics Operations USA
14615 Lone Oak Road
Eden Prairie, MN 55344
USA
Tel: +1 952 937 9800
Fax: +1 952 294 7722
www.hydraulics.eaton.com
Eaton
Hydraulics Operations Asia Pacific
11th Floor Hong Kong New World Tower
300 Huaihai Zhong Road
Shanghai 200021
China
Tel: +86 21 6387 9988
Fax: +86 21 6335 3912
Eaton
Hydraulics Operations Europe
Route de la Longeraie 7
1110 Morges
Switzerland
Tel: +41 21 811 4600
Fax: +41 21 811 4601
V-VLPO-MC005-E_080826.qxd 27-08-2008 1:03 Pagina 18