18 EATON Vickers Solenoid Operated Directional Valves Product Catalog V-VLDI-MC011-E September 2008
Subplates, Connection
Plates and Mounting
Surfaces
General description
This range of subplates and
auxiliary connection plates
are for use with size 3 valves.
/PTIONAL"30&OR3!%5.&
pipe thread connections are
available.
The subplates fall into five
groups:
s3INGLESTATIONSUBPLATES
with either side or rear
entry ports for connecting
to the main system.
s-ULTISTATIONMANIFOLDS
having from two to six
stations. The two service
ports per station are ar-
ranged along one side but
the pressure and tank lines
are internally connected in
parallel to each station.
s4APPINGPLATESFORINSERTION
under modules or valves to
provide access to service
lines, e.g. for pressure
gage connection.
s#ROSSOVERPLATESFORINTER
connecting two sets of
service lines at the top of
module stacks when direc-
tional valves are not fitted.
s"LANKINGPLATEFORTERMI-
nating a valve station e.g.
when the station is not to
be used until later.
The 2 to 6 multi-station sub-
plates, when used together
with Vickers
®
SystemStak
™
valves, provide very compact
control assemblies.
Plates having machined trap-
ezoidal O-ring recesses are
supplied complete with Viton
O-rings.
On all models, the size 03
mounting face includes a
drilled hole (for a location pin)
in conformance with ANSI/
B93.7M) and (NFPA) size
!LL%ATONSIZEVALVES
and auxiliary plates contain
a matching location pin to
ensure correct orientation of
the mounting faces.
Design number subject to change. No change of installation dimensions for designs 10 thru 19. “R”
ORh"vSUFlXn)3/"30&PORTSANDORMETRICATTACHINGBOLTTAPPINGSh3vSUFlXn3!%5.#
ports and/or UNC attaching bolt tappings.
DESCRIPTION AND
MAXIMUM PRESSURE FUNCTIONAL SYMBOL MODEL CODE
Blanking plate DGMA–3–B–1*
250 bar (3600 psi)
Crossover plate DGMA–3–C1–1*
P–A, B–T
250 bar (3600 psi)
Crossover plate DGMA–3–C2–1*
P–B, A–T
250 bar (3600 psi)
Tapping plate DGMA–3–T1–1*–B
Ports A and B DGMA–3–T1–1*–S
250 bar (3600 psi)
Tapping plate DGMA–3–T2–1*–B
Ports P and T DGMA–3–T2–1*–S
250 bar (3600 psi)
Adaptor size 05 to 03 DGAM–3–01–1*–R
207 bar (3000 psi) DGAM–3–01–1*
(UNC valve mtg. bolts)
Single station DGVM–3–1*–R
subplate/manifold DGVM–3–1*–S
Rear ports P,T,A,B
250 bar (3600 psi)
Single station DGMS–3–1E–1*–R
subplate/manifold DGMS–3–1E–1*–S
Side ports P,T,A,B
250 bar (3600 psi)
Multi-station subplate/ DGMS–3–2/3E–1*–R
manifold; side ports DGMS–3–2/3E–1*–S
P,T,A1,B1,A2,B2, etc.
250 bar (3600 psi)
2 station
3 station
Multi-station subplate/ DGMS–3–4/5/6E–1*–R
manifold; side ports DGMS–3–4/5/6E–1*–S
P,T,A1,B1,A2,B2, etc.
250 bar (3600 psi)
4 station
5 station
6 station
P T B A
P T B A
P T B A
P T B A
BT
A
P
P
T
B
1
A
1
P T B A
P
1
T
1
B
1
A
1
B
2
A
2
P
2
T
2
B
2
A
2
P
T
B
1
A
1
P
1
T
1
B
1
A
1
B
6
A
6
P
6
T
6
B
6
A
6
Valve station 1 Valve station 2 – 6
Valve station 1 Valve station 2 – 3
Size 03
Size 05
P T B A
P T B A
P T
A
T
B
B A