Controls
Pressure Compensator
Controls
The pressure compensator con-
trol automatically adjusts pump
delivery to maintain volume
requirements of the system at a
preselected operating pressure.
Maximum pump delivery is
maintained to approximately 75
psi (PVQ20) or 100 psi (PVQ32)
below the pressure setting
before being reduced. The pres-
sure compensator control oper-
ates on one side of center and
has an adjustment range as des-
ignated in the model numbering
system.
Pressure Compensator Control
with Adjustable Maximum
Displacement Stop
The adjustable maximum stop
pressure control enables the
maximum pump delivery to be
externally adjusted from 25% to
100% while maintaining all of
the standard features of a pres-
sure compensated pump. To
assist initial priming, manual
adjustment control setting must
be at least 40% of maximum
flow position.
Remote Control Pressure
Compensator
Exactly the same as the “C”
(pressure compensation option)
except the machine operator is
able to change the compensator
setting through the use of a
remote pilot relief valve, such as
Eaton C-175.
Electric Dual Range Pressure
Compensator Control
The dual range pressure com-
pensator control automatically
adjusts pump delivery to main-
tain volume requirements of the
system at either of two prese-
lected operating pressures.
Maximum pump delivery is
maintained to approximately 75
psi (PVQ20) or 100 psi (PVQ32)
below either pressure control
setting before being reduced.
Control type and pressure range
are designated in the model
number system.
Note: Graphic symbols shown with external
valve(s) and cylinder to illustrate typical
usage.
Load-sensing and Pressure
Limiter Compensator Control
This compensator provides
load-sensing control under all
pressure conditions up to the
desired maximum. It automati-
cally adjusts pump flow in
response to a remote pressure
signal and maintains outlet pres-
sure at a level slightly above load
pressure. The integral pressure
limiter overrides the load-sens-
ing control, reducing pump dis-
placement as the preset maxi-
mum operating pressure
is reached.
Standard load-sense differential
pressure settings, by control
type, follow. See model number
system for setting range.
Standard load-sensing and pres-
sure limiting control with 11 bar
differential pressure (standard
factory setting). Includes bleed-
down orifice to exhaust load-
sense signal for low-pressure
standby condition.
Same as C**V11B above, but
with bleed-down orifice plugged.
Same as C**V11B, but with fac-
tory differential pressure setting
of 24 bar.
Same as C**V11P, but with fac-
tory differential pressure setting
of 24 bar.