EATON DG5V-7 30 Design & DG3V-7 20 E-VLVI-SS001-E1 October 2015 I-3
I
Model Code
DG3V-7 30 Series, Pilot Operated Directional Valves
Fluid Compatibility
Blank – Standard BUNA-
Nitrile Seals
F3 – Viton Seals
Note: For further information see “Hydrau-
lic Fluids” section on page 13.
Spool type
See “Functional Symbols”
section on pages 5-6.
Spool spring
arrangement
A – Spring offset, end-to-end
(P to B when operated)
AL – As “A” but left-hand
build
(P to A when operated)
B – Spring offset, end-
tocenter
(P to B when operated)
BL – As “B” but left-hand
build
(P to A when operated)
C – Spring centered
N – Two-position detented
DG5V option. Same function from
DG3V-7-*C valves by alternating pilot
supply to one port (X or Y) and permanently
draining the other.
Spool Control
Omit if not required
1 – Stroke adjustment at both
ends
2 – Pilot choke adjustment
both ends
3 – “1” and “2” combined
7 – Stroke adjustment, port A
end only
8 – Stroke adjustment, port B
end only
27 – “2” and “7” combined
28 – “2” and “8” combined
Omit if not required
Not applicable to DG5V-7-*B(L) models.
Not applicable to models shown in the
“Spring offset, end-to-center, opposite
hand” section on page 6
Not applicable to models shown in the
“Spring offset, end-to-center” section on
page 6
Not applicable for spool “8” models
Main Stage Spool Moni-
toring Switch
Blank – None
PCA – Center sensing switch
on “A” port end
PCB – Center sensing switch
on “B” port end
PDA – Double offset sensing
switch on “A” port end
PDB – Double offset sensing
switch on “B” port end
PCD – Center sensing switch
on “A” port end and
double offset sensing
switch on “B” port
end
PPA – Offset sensing
proximity switch “A”
port end
PPB – Offset sensing
proximity swtich “B”
port end
PPD – Offset sensing
proximity switch both
ends
* The spool position monitoring switch
shown on this technical document is CE
marked and certied and complies to
European Standard EN 61000-6-4: 2001
(Emissions) for Class A and European
Standard EN 61000-6-2: 2001 (Immunity).
Not applicable for spool “8” models
External Pilot Supply,
DG5V Valve Option
Omit for internal pilot supply
E – Valve congured for external
pilot supply to port X
Internal Pilot Drain,
DG5V Valve Option
Omit for external drain, which
is also mandatory for 1, 8 and
9 spool-type valves
T – Valve congured for
internal pilot valve drain.
Minimum Pilot Pressure
Generator (P Port
Option)
Blank – None
K- 0.35 bar cracking pressure
Manual Override Option
Blank – Plain override in
solenoid end(s) only
H – Water-resistant manual
override on solenoid
end(s)
W – Twist & lock override in
solenoid ends •
Z – No override at either end
No override in non-
solenoid end of single-
solenoid valves.
• DC only
Solenoid Energization
Indentity
V – Solenoid “A” is at port
A end of pilot valve and/
or solenoid “B” at port B
end independent of main-
stage valve port locations
or spool type; German
practice.
Omit (except as noted below)
for US ANSI B93.9 standard
whereby solenoid “A” is
that which, when energized,
connects P to A in main-stage
valve, and/or solenoid “B”
connects P to B.
Note: Energization identities on valves
with type 8 spools are identical under US
and German practices. In such cases the
“V” code is used.
Solenoid Type
Connection(s)
U – ISO4400, DIN43650
connector
U1 – ISO4400 tted with
PG11 plug
U6 – ISO4400 with tted DIN
plug with lights
KU – Top exit ying lead
(150mm)
KUP4 – Junior timer (Amp)
connector
KUP5 – Integral Deutsch
connector
FW – Flying lead with 1/2”
NPT thread wiring
housing
FTW – Fly. lead wired
terminal block & 1/2”
NPT thread wiring
housing
FPA3W – Fly. lead, 3 Pin
connector &
1/2” NPT thread
wiring housing
singlesolenoid valves
FPA5W – Fly. lead, 5 pin
connector & 1/2”
NPT thread wiring
housing
1
2
5
7
10
8
9
3
4
* - DG3V-7- ** ** (-**) - 20
For pilot operated valves:
For solenoid controlled, pilot operated valves:
* - DG5V-7- ** ** (-**) (-P**) (-E) (-T) - (-K) - (-*) - (V) M - ***** (L) - ** - ***- * - 30
1
1
2 3
2 3 15
14
15 166 7 8 9 10 124 5 11 13
4
6
11