EATON Vickers Screw-in Cartridge Valves V-VLOV-MC001-E1 June 2003
G-38
Description
The POC1-12 is a pilot-to-
open, screw-in cartridge
type check valve.
POC1-12
Pilot operated check valve
Operation
The POC1-12 will positively
lock a load from port 1 to
port 2, but will release the
load by applying pressure
to the pilot port (port 3).
The load can also be
released by adjusting the
optional override.
RATINGS AND SPECIFICATIONS
Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49˚C (120˚F)
Typical application pressure (all ports) 350 bar (5000 psi)
Cartridge fatigue pressure (infinite life) 310 bar (4500 psi)
Rated flow 114 L/min (30 USgpm)
Pilot ratio 3:1
Internal leakage, Port 1 to 2 5 drops / min. maximum
@ 350 bar (5000 psi)
Free flow cracking pressure @ 1.0 L/min (0.25 USgpm) 0,3 bar (5 psi);
2,0 bar (30 psi); 5,1 bar (75 psi); 6,9 bar (100 psi)
Hysteresis less than 3 bar (45 psi)
Temperature range –40˚ to 120˚C (–40˚ to 248˚F)
Cavity C–12–3S
Fluids All general purpose hydraulic fluids such as:
MIL–H–5606, SAE 10, SAE 20, etc.
Filtration Cleanliness code 18/16/13
Standard housing materials Aluminum or steel
Weight cartridge w/out override 0,26 kg (0.58 lb)
cartridge w/override 0,34 kg (0.74 lb)
Seal kit 02-180095 Buna-N
02-165887 Viton
®
Viton is a registered trademark of E.I.DuPont
3:1 Ratio
Crack Pressure + Port 1 Pressure - Port 2 Pressure
3
+ Port 2 pressurePilot pressure, nominal at Port 3 =
Functional Symbols
Sectional View
Pressure Drop Curves
Cartridge only
A – 100 psi
B – 75 psi
C – 30 psi
D – 5 psi
E – Full pilot
WARNING
Do not use Pilot-
to-Open check
valves in load
holding applications where
either overrunning loads are
possible; or, load release
speed is critical. Failure to
observe these guidelines
may result in bodily injury or
damage to equipment.