Directional Controls DG4V4-01
1* Design
Flows to 115 L/min (30 USgpm)
315 bar (4570 psi)
EATON Directional Controls DG4V4-01 V-VLDI-MC013-E1 October 2015
2
Contents
Description Page No.
Introduction 3
Features and benets 3
DG4V4-01, 1* Design 4
Model code 5-6
Performance characteristics 7
Specications 8
Flow curves 9
Pressure drop 10
Installation dimensions 11
Electrical plugs and connectors 12
Subplate and mounting surface 13
M12 Connectors feature 14-16
Notes 17
EATON Directional Controls DG4V4-01 V-VLDI-MC013-E1 October 2015
3
This wet armature solenoid operated directional
control valve is for directing and stopping flow at any
point in a hydraulic system. Its primary function is to
determine the direction of the fluid flow in a work
cylinder or determine the direction of rotation of
a fluid motor.
These valves are designed to meet the requirements
of high performance, precision industrial hydraulic
systems operating at pressures up to 315 bar (4570
psi) and flows to 115 L/min (30 USgpm). They mount
on the ISO size 05 mounting surface.
The performance of the most conventional solenoid
operated directional valves is limited by the flow
forces acting on the spool in opposition to the
solenoids and return springs. Special attention
is given to compensating for, or minimizing,
these undesirable forces in the design of the
series 5 valve.
Introduction
Features and benefits
High performance
High pressure and flow capability with performance comparable to
competitors, due to 315 bar (4570 psi) and 115 L/min (30 USgpm)
ratings.
Reliability
A high margin of shifting force is available to overcome spool friction
due to dirt and other contaminants. Also, a balance spool with
cushioned shift means less wear and long life.
Wet armature solenoids for quieter operation and long life with no
dynamic seal leakage.
Molded coil construction is impervious to moisture and dirt.
Larger diameter spool combined with constant area and tangential
flow passages result in low pressure drop.
Stainless steel solenoid pin is processed hardened for long life.
Patented detent mechanism for greater reliability and long life.
Serviceability
Plug-in coils and electrical connections simplify maintenance.
Cartridge style manual actuators; easily replaced or exchanged for
an SAE plug.
Plug–in solenoid coil for ease of servicing can be replaced without
disturbing the hydraulic system or wiring cavity.
Two solenoid sizes to choose from for optimum performance and
cost selection.
Optional pin-type or top-side plug-in electrical connectors for easy
valve replacement. Reversible to fit any installation need.
Dual frequency (50/60 Hz) 2-wire coils for lower inventory at the
OEM (optional).
EATON Directional Controls DG4V4-01 V-VLDI-MC013-E1 October 2015
4
DG4V4-01, 1* Design
Optimum performance features
Equalizes hydraulic force on ends of the spool and cushions
spool shift.
When spool is shifted, the fluid displaced from one end of the
spool is transferred to the other end through this passage which is
designed to provide a cushioning effect and balance the spool.
Spool land sequencing
Accurate sequencing of land opening and closing provides maximum
axial stability.
In the example above, it is important that the flow path A to T is
opened before the path P to B to prevent pressure intensification
which could upset axial balance and limit valve function.
Isolated solenoid chambers
Transient pressure peaks in the solenoid to prevent solenoid tube
failure are minimized.
Pressure surges can occur within the armature tube of 2-land wet
armature valves due to cylinder port decompression. These surges
can easily exceed tube pressure rating and result in premature
tube failure.
The armature tube area is isolated from the tank port area by the
outboard lands on the 4-land spool. Tank port pressure surges do not
reach the armature tube to cause failure.
Spool force-balancing contour
The hydraulic unbalancing effects of fluid momentum between the
cylinder and tank ports is minimized.
Flow forces that are developed at the conventional square land
orifice (P to B) are partially compensated for by the force balancing
contour on the outer spool lands (A to T).
EATON Directional Controls DG4V4-01 V-VLDI-MC013-E1 October 2015
5
Model code
1
2
4
F* - DG4V4-01 - ** - *(L) - (Z) - (V)M - (S*) - ** - *** - * - (L) - ** - *(L) - * - 1* - S***
5
9 11 14123 6
7 8
10 13 15 16 17 18
1
Special seals
Omit if not required.
F3 Seals for fire retardant fluids
F6 Seals for water glycol
2
Motor power (sizes)
DG4V4-01 Subplate mounting; solenoid operated.
Pressure rating 315 bar (4570 psi) for
ports P, A & B.
3
Spool type
0 Open center (all ports))
1 Open center (P to A & T) B blocked
2 Closed center (all ports)
3 Open center (P & B blocked) A to T
6 Closed center (P blocked) A & B to T
7 Open center (P to A & B) T blocked
8 Tandem center (P to T) open crossover
11 Open center (P to B & T) A blocked
22 Closed center (two way)
31 Closed center (P & A blocked) B to T
33 Closed center, bleed A & B to T
4
Spool/Spring arrangement
A Spring offset, end-to-end
B
Spring offset, end to center
C
Spring centered
N
No spring detented
5
Left hand build
Omit if not required.
L Omit for right hand build
6
Manual override options
Omit if serviceable.
Z No manual override
7
Solenoid energization identity
V Solenoid ‘A’ is at port ‘A’ end/or solenoid ‘‘B’’ is
at port ‘‘B’’ end, independent of spool type.
Omit for U.S. ANSI B93.9 standard requiring
solenoid ‘A’ energization to connect P to A and/
or solenoid ‘‘B’’ to connect P to B, independent
of solenoid location.
8
Flag symbol
M Electrical options and features
9
Spool indicator switch
S3 Switch, wired normally open
S4 Switch, wired normally closed
10
Coil type
Omit for plug-in.
U ISO 4400 (DIN 43650) mounting+
U1
Connector fitted
U6
Connector fitted with lights
KUPM4L
Integral M12, 4-Pin connector
refer to pages 14 - 16 for more information.
Female connector to be supplied by customer.
11
Junction box with electrical connectors
PA Insta-plug male receptacle only
PB Insta-plug male & female receptacle
PA3 Three pin connector
PA5 Five pin connector
PA4 Mini connector
12
Junction box threads
G G½ BSP thread wiring housing
J 20 mm thread wiring housing
W 1/2” NPT thread wiring housing
EATON Directional Controls DG4V4-01 V-VLDI-MC013-E1 October 2015
6
Model code continued
13
Solenoid indicator lights
Omit if not required.
L Lights fitted
14
Coil rating (Standard power)
Omit for low power
A 110V AC 50 Hz
B 110V AC 50 Hz/120V AC 60 Hz
C 220V AC 50 Hz
D 220V AC 50 Hz/240V AC 60 Hz
DP 125V DC
ED 240V AC 50 Hz
G 12V DC
H 24V DC
NN 24V AC 50 Hz
OJ 48V DC
X 250V DC
15
Coil rating (Low power)*
Omit for standard power.
AL 110V AC 50 Hz
BL 110V AC 50 Hz/120V AC 60 Hz
CL 220V AC 50 Hz
DL 220V AC 50 Hz/240V AC 60 Hz
DML 80V DC
EDL 240V AC 50 Hz
NNL 24V AC 50 Hz
NVL 24V AC 60 Hz
PL 110V DC
XL 250V DC
*F6 seals not available with DC low power voltages.
16
Port T code
4 70 bar (1000 psi) (Low power)
5 120 bar (1750 psi) (Standard power)
17
Design number
Subject to change, installation dimensions remain
as shown for design numbers 10 through 19.
18
Special features
S Special suffix
1
2
4
F* - DG4V4-01 - ** - *(L) - (Z) - (V)M - (S*) - ** - *** - * - (L) - ** - *(L) - * - 1* - S***
5
9 11 14123 6
7 8
10 13 15 16 17 18
EATON Directional Controls DG4V4-01 V-VLDI-MC013-E1 October 2015
7
Maximum pressure
Ports P, A & B 315 bar (4570psi)*
Port T 120 bar (1750 psi)
(See Model Code)
* 70 bar (1000 psi) with high water base fluids (95% maximum
water content) or low watt coils
Solenoid energizing
Spring centered and spring offset valves will be spring positioned
unless the solenoid is energized continuously. No-spring detented
valves may be energized momentarily, approximately 0.15 second;
when the solenoid is de-energized the spool will remain in the last
position attained, provided there is no shock, vibration or unusual
pressure transients.
!
CAUTION
Any sliding spool valve, if held shifted under pressure for long
periods, may stick and not return, due to silting. Therefore, it is
recommended that the valve be cycled periodically to prevent this
from occurring.
Response Time
The following response times were measured from the point of
energization/ de-energization to the point of first indication of inlet
pressure change. Response up to full system pressure is
dependent on the system’s compressed volume and can vary
with each application.
Performance characteristics
Standard
Solenoid
Voltage Rating
Inrush
Amps (rms)
Holding
Amps (rms)
Holding-
Watts
120V AC 60 Hz 3.95 0.98 37
110V AC 50 Hz 4.10 0.98 37
240V AC 60 Hz 1.97 0.49 37
220V AC 50 Hz 1.77 0.49 36
110V AC 50 Hz 3.25 0.77 30
220V AC 50 Hz 1.55 0.42 28
240V AC 50 Hz 1.55 0.42 28
12V DC 3.64 45
24V DC 1.83 45
Series Valve type
AC Solenoid DC Solenoid
Solenoid
Energized
Spring
Return
Solenoid
Energized
Spring
Return
Standard
Low Power
Spring centered 20 ms
20 ms
50 ms
35 ms
50 ms
40 ms
80 ms
35 ms
Standard
Low Power
Spring offset 18 ms
15 ms
25 ms
35 ms
50 ms
50 ms
50 ms
15 ms
Standard
Low Power
Detented 22 ms
15 ms
120 ms
Low Power
Solenoid
Voltage Rating
Inrush
Amps (rms)
Holding
Amps (rms)
Holding-
Watts
120V AC 60 Hz 2.40 0.69 27.5
110V AC 50 Hz 2.40 0.78 28.5
240V AC 60 Hz 1.15 0.25 27.5
220V AC 50 Hz 1.10 0.35 28.5
110V AC 50 Hz 2.40 0.61 23
220V AC 50 Hz 1.00 0.24 23
240V AC 50 Hz 1.20 0.26 23
12V DC 2.33 33
24V DC 1.25 30
EATON Directional Controls DG4V4-01 V-VLDI-MC013-E1 October 2015
8
Specifications
Valve function, symbol and recommended maximum flow
(See page 7 for maximum flow curves).
Maximum flow data
Maximum recommended flow
data is for AC or DC solenoids
at 90% nominal voltage in a
4-way circuit with cylinder ports
either looped or blocked and
containing 2,5 liter (0.66 USgpm)
compressed volume. Reduced
performance may result when
certain spools are used in
3-way circuits.
Fluids and seals
Buna N seals are standard and
are compatible with water-in-
oil emulsions, high water base
fluids and petroleum oils. For
phosphate ester fire resistant
fluids, Viton® seals must be
specified. Seals for water
glycol have an F6 designation.
Maximum operating pressure
for high water base fluids is
1000 psi.
Application recommendations
Filtration: ISO 4406 Code
20/18/15 Operating Temperature:
20 to 50 C (70 to 120 F) Fluid
Viscosity: 16 - 51 cSt (75 - 250
SUS)
Spool
Type
3 Position
Spring Centered (C)
Max. Flow Curve
Spool
Type
2 Position Detented (N)
Max. Flow Curve
Standard Low Power Standard Low Power
AC DC AC DC AC DC AC DC
0 1 10 17 21 0 1 11 17 N/A
1 6 13 18 N/A 2 1 11 18 N/A
2 1 10 17 21
2 Position Spring Offset to
Port A (A)
3 4 11 18 21 0 7 14 17 21
6 3 11 18 21 2 7 14 17 21
7 1 10 17 21 22 9 16 N/A N/A
8 5 12 20 21
2 Position Spring Offset to
Port B (B)
13 1 10 17 21 0 7 14 17 21
33 2 11 18 21 2 8 15 19 21
22 9 16 N/A N/A
EATON Directional Controls DG4V4-01 V-VLDI-MC013-E1 October 2015
9
Flow curves
Maximum flow curves
9 8
Standard AC A/B
048121620242832
020406080 100
120
350
280
210
140
70
0
Pressure
Bar PSI
USgpm
L/min
Flow
7
5000
4000
3000
2000
1000
0
5
3
2
1
5000
4000
3000
2000
1000
0
048121620242832
020406080 100
120
350
280
210
140
70
0
Pressure
Bar PSI
USgpm
L/min
Standard AC C/N
6
4
Flow
21
20
19
18
17
5000
4000
3000
2000
1000
0
048121620242832
020406080 100
120
350
280
210
140
70
0
Pressure
Bar PSI
USgpm
L/min
Low Power AC & DC A/B/C/N
Flow
16
15
14
5000
4000
3000
2000
1000
0
048121620242832
020406080 100
120
350
280
210
140
70
0
Pressure
Bar PSI
USgpm
L/min
Standard DC A/B
Flow
13
12
1110
5000
4000
3000
2000
1000
0
048121620242832
020406080 100
120
350
280
210
140
70
0
Pressure
Bar PSI
USgpm
L/min
Standard DC C/N
Flow
EATON Directional Controls DG4V4-01 V-VLDI-MC013-E1 October 2015
10
Pressure drop
Pressure drops in offset positions except where otherwise
indicated
For other viscosities, pressure drops approximate to:
A change to another specific gravity will yield an approximately
proportional change in pressure drop.
The specific gravity of a fluid may be obtained from its producer. Fire
resistant fluids usually have higher specific gravities than oil.
Drain
On 2-way valves, ‘‘T’’ is the drain and must be connected to the tank
through a surge-free line, so there will be no back pressure at
this port.
Spool code P to A P to B A to T B to T P to T
0 1 1 1 2 1
1 3 4 1 6 4
2 4 4 2 3
3 4 4 1 3
6 4 4 1 2
7 1 1 4 6
8 7 7 4 4 3
11 4 3 6 1 _
22 4 4
31 4 4 3 1
33 4 4 3 3
Viscosity cSt (SUS)
14 20 43 54 65 76 85
(17.5) (97.8) (200) (251) (302) (352) (399)
% of ∆P
81 88 104 111 116 120 124
Pressure Drop
Flow
Bar PSI
USgpm
L/min
18
16
14
12
10
8
6
4
2
0
280
240
200
160
120
80
40
0
048121620242832
0204060
80 100 120
7
6
4
3
2
1
!
CAUTION
Surges of oil in a common line serving these and other valves can
be of sufficient magnitude to cause inadvertent shifting of these
valves. This is particularly critical in the no-spring detented type
valves. Separate tank lines, or a vented manifold with a continuous
downward path to tank are necessary. Consult your Vickers
representative for instructions.
EATON Directional Controls DG4V4-01 V-VLDI-MC013-E1 October 2015
11
Installation dimensions
116.6
(4.59)
114,3
(4.50)
89,7
(3.53)
35,8
(1.41)
14,2
(0.56)
28,7
(1.13)
92,2 (3.63) AC
131,8 (5.19) DC
283,3 (9.38) AC
316,7 (12.47) DC
35,1
(1.38)
69,9
(2.75)
72,1
(2.84)
174,8 (6.88) AC
214,4 (8.44) DC
226,3 (8.91)
(PB*W)
Electrical current
Signal light (‘‘Lights’’ & ‘‘PB’’)
2 places Sol. A Light
NFPA D02 mounting surface
(ISO 4401-AC-05-4-A)
S3, S4 Switch
4-Valve mounting holes
for socket head cap screws
1/4-20x1-1/2 or M6x40 metric
SAE Grade 8 or better, metric grade 10.9
Torque 12-15 N.m (110-130 lb. in.)
‘G’’ - BSP
‘J’’ - 20mm thread
‘W’’-1/2” NPT
Connection box
may be rotated 180
Manual operating
Pin (both ends)
Across Flats
(both ends)
Clearance required for Coil
removal (both ends)
3rd angel projection
46,8 (1.84) AC
87,4 (3.44) DC
Sol. B Light
Standard Conduit Box & ‘PB’ Insta-plug
EATON Directional Controls DG4V4-01 V-VLDI-MC013-E1 October 2015
12
Electrical plugs and connectors
100,1
(3.94)
283,3 (9.38) AC
316,7 (12.47) DC
109,5
(4.31)
74,7
(2.94)
114,3
(4.50)
230,6 (9.08) AC
262,6 (10.34) DC
283,3 (9.38)
116,6
(4.59)
‘L’ Low power option
PA Connector option, Pin type
‘PA3’/‘PA5’ (NFPA T 3.5.29)
PM4 (SAE H1738-2)
‘U’ DIN 43650 Connector* option
Connector plug with lights (U6)
*Connector plug not included with valve
Single Solenoid
Valve (PA3)
Double Solenoid
Valve or Optional
Single Solenoid
Valve (PA5)
Double Solenoid
Valve or Optional
Single Solenoid
Valve (PM4)
Connector plug without lights (U1)
Number of
Solenoids
Number
of pins
Option
code
Single 3 PA3
Single or Double 5 PA5
Single or Double 4 PM4
EATON Directional Controls DG4V4-01 V-VLDI-MC013-E1 October 2015
13
Subplate and mounting surface
When subplate is not used, a machined pad (as indicated by subplate
shaded area) must be provided for mounting; pad must be flat within
0.0127 mm (.0005 inch) and smooth within 1.6 flm (63 microinch).
“Ppressure conn.
.2500 –20 UNC–2B thd
4–holes for mounting
.750 16 UNF 2B Thd. for .500 O.D.
tubing. 4 holes (system connections)
20,5
(0.81)
18,2
(0.72)
23,8 (0.94)
23,1
(0.91)
53,9
(2.12)
79,3
(3.12)
33,0
(1.30)
*“A” Cyl. conn.
12,7
(0.50)
11,1
(0.44)
R
*
T
tank conn.
47,7
(1.88)
26,1
(1.03)
14,9 (0.59)
6,3 (0.25)
11,9
(0.47)
R
50,8 (2.00)
39,6 (1.56)
10,4 (0.41)
10,4 (0.41)
23,8 (0.94)
10,3 (0.40) D. thru 20.5 (0.81) D.
Spotface 4–holes for mounting
.438 dia system port 4 holes
68,3 (2.69)
*
B
cyl conn.
91,9
(3.62)
45,9
(1.81)
23,1
(0.91)
47,7
(1.88)
114,3
(4.50)
43,6
(1.72)
15,7 (0.62)
3,5 (0.22)
28,4 (1.12)
5,5
(0.22)
A
B
P
T
A
101,6
(4.00)
*Ports on model DGSME–01–20–T8 only
Model Dimension "A"
DGSM–01–20–T8 31,75 (1.25)
DGSME–01–20–T8 38,10 (1.50)
Bolt kits
Bolt kits include 4 directional valve mounting bolts and are
ordered separately.
Note : Metric grade 10.9 (SAE Grade 8) mounting bolts required.
Fluid cleanliness
Essential information on the correct methods for treating hydraulic
fluid is included in Vickers publication 561 “Vickers Guide to
Systemic Contamination Control” available from your local Vickers
distributor or by contacting Vickers, Incorporated. Recommendations
on filtration and the selection of products to control fluid condition
are included in 561.
Recommended cleanliness levels, using petroleum oil under
common conditions, are based on the highest fluid pressure levels
in the system. Fluids other than petroleum, severe service cycles, or
temperature extremes are cause for adjustment of these cleanliness
codes. See Vickers publication 561 for exact details.
Filtration requirements
20/18/15
Model Codes Sizes Thread
BKDG01-633 ¼-20-1½ Inch
BK855993M M6x1x40 Metric
EATON Directional Controls DG4V4-01 V-VLDI-MC013-E1 October 2015
14
M12 Connectors feature
Seal Type
“F6” - For use with water based uids
Blank - For use with petroleum oils
Spool/spring arrangement
Left hand build ( omit if not required)
Manual override
Solenoid energization identity
Blank - standard arrangement for ANSI B93.9
Flag symbol heading electrical features and options
Coil type - “KUMP4” - integral M12, 4-PIN connector
Solenoid indicator lights
Surge suppressor/damper - “D7” - encapsulated trans
Coil identication letter
Power - low watt (omit for standard power)
“4” - 70 Bar (1000 PSI) low watt
“5” - 120 Bar (1750 PSI) standard p
ower
Tank pressure rating
Design number
(F*) - DG4V4 - 01***(L) - (Z) - (V)M - KUPM4L - D7 - *(L) - * - 10
“V” - solenoid identication determined by solenoid position
Blank - servicable override
“Z” - no override
“A” - Spring offset (single solenoid)
“C” - Spring centered
“N” - No spring detented
Directional control valve
Subplate mounted
Solenoid operated
315 bar (4570 PSI) on P, A and B ports
4- Way ow direction
Spool type
Valve size - NFPA D05, CETOP RP35H size 5
(IOS 4401-AC-5-4-A) Interface (1/8” Nominal size)
“F3” - For use with phosphate ester uids
EATON Directional Controls DG4V4-01 V-VLDI-MC013-E1 October 2015
15
M12 Connectors feature
+24 Volt (positive) PIN #4
Key (Ref.)
Pins #1 and #2 are unused
Interface protected by
shipping cover
“B”
Dual solenoid models
interface complies to NFPA D02
ISO 4401-AC-05-4-A
Seals provided
Standard power
Single solenoid models
314.43 [12.379]
214.35 [8.439]
108.00 [4.252]
98.40 [3.874]
“A”
-0 Volt (negative) PIN #3
23.02 [.906]
46.02 [1.812]
88.49 [3.484]
70.21 [2.764]
Electrical schematic
(F*) - DG4V4 - 01***(L) - (Z) - (V)M - KUPM4L - D7 - * - 5 10 Series
EATON Directional Controls DG4V4-01 V-VLDI-MC013-E1 October 2015
16
M12 Connectors feature
-0 Volt (negative) PIN #3
+24 Volt (positive) PIN #4
Key (Ref.)
Pins #1 and #2 are unused
23.02 [.906]
46.02 [1.812]
Interface protected by
shipping cover
“B” “A”
Dual solenoid models
interface complies to NFPA D02
ISO 4401-AC-05-4-A
Seals provided
Single solenoid models
243.79 [9.598]
73.37 [2.889]
70.21 [2.764]
179.04 [7.049]
98.40 [3.874]
72.69 [2.862]
Electrical schematic
(F*) - DG4V4 - 01***(L) - (Z) - (V)M - KUPM4L - D7 - *L - 4 10 Series
Low watt
EATON Directional Controls DG4V4-01 V-VLDI-MC013-E1 October 2015
17
Notes
© 2015 Eaton
All Rights Reserved
Printed in USA
Document No. V-VLDI-MC013-E1
October 2015
Eaton
Hydraulics Group USA
14615 Lone Oak Road
Eden Prairie, MN 55344
USA
Tel: 952-937-9800
Fax: 952-294-7722
www.eaton.com/hydraulics
Eaton
Hydraulics Group Europe
Route de la Longeraie 7
1110 Morges
Switzerland
Tel: +41 (0) 21 811 4600
Fax: +41 (0) 21 811 4601
Eaton
Hydraulics Group Asia Pacic
Eaton Building
No.7 Lane 280 Linhong Road
Changning District,
Shanghai 200335
China
Tel: (+86 21) 5200 0099
Fax: (+86 21) 2230 7240