Model Codes
(F3-)CVUA-6-PD * -M-U-
1 4 5
-1*-* *
6 7
For DG*VP Valves
(F3-)DG* VP-3-
1 2
-1*10** -VM-U-
6 7
*
3
1
2
3
4
5
6
7
A.2
For CVUA Cartridge Valves
Prefix, fluid compatibility
Blank = For petroleum oils, water
glycols and invert emulsions
F3 = For phosphate esters,
petroleum oils, water glycols
and invert emulsions
Function
3 = Three-way
4 = Four-way
Spool and spring arrangement
102A = Normally open, spring offset;
option for DG3VP models
103A = Normally closed, spring offset;
option for DG3VP models
104C = Normally open, spring
centered; option for DG4VP
models
105C = Normally closed, spring
centered; option for DG4VP
models
Mounting flange type
N = Narrow thickness flange
W = Wide thickness flange
Function
2 = Two-way
3 = Three-way
Coil rating
B = 110 V AC 50/115 V AC 60
D = 220 V AC 50/230 V AC 60
G = 12 V DC
H = 24 V DC
Design number, 10 series
Subject to change. Installation
dimensions unaltered for design
numbers 10 to 19 inclusive.
For Electrical Plugs
See “Installation Dimensions” section.
For Tool Kits for CVUA Valves
See “Installation Dimensions” section.
For Mounting Subplates and Bolt Kits
for DG*VP Models
See catalogs 2425 and 2314.
Note: CVUA valves are supplied
complete with mounting flanges and
metric fixing bolts.
Operating Data
Pressure and Flow Limits
Max. Pressure
Non-F3-Prefix Models:
For t10 switching
cycles/min 315 bar (4500 psi). . . . . . . . .
For 10 to 180 switching
cycles/min 210 bar (3000 psi). . . . . . . . .
F3-Prefix Models:
Up to 180 switching
cycles/min 210 bar (3000 psi). . . . . . . . .
Note: For all valves lower limits may
apply if high-water-based fluids (e.g.
5%/95% oil-in-water emulsions) are to
be used; contact your Vickers
representative.
Max. Flow Rate Up to 20 L/min. . . . . . .
(5.3 USgpm)
Control Data
Rated Power Supply
See “Model Codes” section.
Power Consumption, AC Solenoids
Inrush, max.Y VA 396. . . . . . . . . . . . . . .
Steady-state B VA 198. . . . . . . . . . . . . . .
Holding VA 57. . . . . . . . . . . . . . . . . . . . . .
All above values are RMS
Y Armature fully retracted, 1st half-cycle.
B At start of normal working stroke of valve
spool. Previously called “Inrush”.
Power Consumption, DC Solenoids
At rated voltage and wire
temperature of 20_C (68_F) 38W. . . . . .
Relative Duty Factor
100% continuous rating
Type of Protection
Weatherproof to IEC 144 Class IP65
Winding insulation to Class H
Epoxy resin to Class F
Permissible Voltage Fluctuation
"5% of rated voltage