Operation
The valve remains closed until
the spring bias is reached
at port 1 at which time the
poppet lifts of the seat and
allows ow from port 1 to port
2. in the other direction the
valve is closed.
Pilot operation
Hardened and ground working
parts to limit leakage and
extend service life. Robust
design with a 350 bar max
pressure rating.
Pressure drop
Performance data
Sectional view
CV11-12 - Check valve
Direct acting, poppet type
114 L/min (30 USgpm) • 350 bar (5000 psi)
Description
This is a poppet type, direct
acting screw-in cartridge
check valve allowing free ow
from port 1 to 2.
A – CV11-12-P-O-80
B – CV11-12-P-O-20
C – CV11-12-P-O-2.5
Flow - L/min (21,8 cSt oil @ 49°C)
Flow - USgpm (105 SUS oil @ 120°F)
Pressure Drop - bar
0
05 10 1520 2530
2
10080604020
50
100
150
200
250
300
4
6
8
10
12
14
16
18
A
B
C
Pressure Drop - psi
2
1
2
1
Ratings and specifications
Performance data is typical with fluid at 21,8 cST (105 SUS) and 49°C (120°F)
Typical application pressure (all ports) 350 bar (5000 psi)
Cartrid ge fatigue pressure (infinite life) 350 bar (5000 psi)
Rated flow 114 L/min (30 USgpm)
Free flow cracking pressures @ 1.0 L/min (0.25 USgpm) 2.5 -
5.0 -
10.0 -
20.0 -
40.0 -
80.0 -
160.0 -
0.17 bar
0.35 bar
0.69 bar
1.38 bar
2,76 bar
5,50 bar
11,0 bar
(2.5 psi)
(5 psi)
(10 psi)
(20 psi)
(4 0 psi)
(80 psi)
(160 psi)
In ternal leakage, Port 2 to 1 5 drops/min. maximum @ 350 bar (5000 psi)
Hysteresis Less than 0,35 bar ( 5 psi)
Temperature range –4 to 120°C (–4 0° to 248°F)
Cavity C-12-2 or C-12-2U
Fluids All general purpose hydraulic fluids such as
MIL - H-5606, SAE 10, SAE 20, etc.
Filtration Cleanliness code 18/16/13
Standard housing materials Aluminum or steel
Weight, cartridge only 0,24 kg (0.54 lbs.)
Seal kit 02-165889 (Buna-N)
02-165888 (Viton
®
)
Viton is a registered trademark of E.I. DuPont
G-21
G
Where measurements are critical request certied drawings. We reserve the right to change specications without notice.
Eaton Hydraulic Screw-in Cartridge Valves (SiCV) E-VLSC-MC001
-E—January 20
18 www.eaton.com
1
Function
CV11 - Check valve
2
Size
12 - 12 size
3
Seal material
Blank - Buna-N
V - Viton
4
Style
P - Poppet
5
Valve housing material
Omit fo r c ar tri dg e o nl y
A - Aluminum
S - Steel
Model code
6
Port size
9
Special features
00 - None
(Only required if valve has
special features, omitted
if "00")
CV11-12 - Check valve
Direct acting, poppet type
114 L/min (30 USgpm) • 350 bar (5000 psi)
8
Cracking pressure
2.5 - 0,17 bar (2.55 psi)
5.0 - 0,35 bar 5 psi)
10 - 0,69 bar (10 psi)
20 - 1,38 bar (20 psi)
40 - 2,75 bar (40 psi)
80 - 5,50 bar (80 psi)
160 - 11,0 bar (160 psi)
Warning
Aluminum housings can be
used for pressures up to
210 bar (3000 psi). Steel
housings must be used for
operating pressures above
210 bar (3000 psi).
7
Cavity
Blank - Cavity without
undercut
U - Cavity with undercut
18,9
(0.75)
44,7
(1.76)
1,6 (1.25) hex
1.062"–12 Thd.
Ø 23,75 (0.935)
2
1
Dimensions
mm (inch)
Torque cartridge in housing
A - 81-95 Nm (60-70 ft. lbs).
S - 102-115 Nm (75-85 ft. lbs).
Installation drawing (Steel)Cartridge only
Basic code
CV11
12.7
(0.50)
63.5
(2.500)
63.5
(2.500)
88.9
(3.50)
88.9
(3.50)
28.7
(1.13)
12.7
(0.50)
18.9
(0.74)
2 X Ø 10.31
(0.46)
25.4
(1.00)
50.8
(2.00)
1
2
Code Port size Housing number
C-12-2U
Aluminum
light duty
C-12-2
Aluminum
fatigue rated
C-12-2U
Steel
fatigue rated
C-12-2
Steel
fatigued rated
0 Cartrid ge only
10T SAE 1002-160641 02-16064002-169817 02-169744
12T SAE 1202-16064502-160644 02-168790 02-169782
4G 1/2" BSPP 02-16111602-161118 02-17251202-172062
6G 3/4BSPP 02-16111502-161117 02-162922 02-169665
See section J for housing details.
00
CV11 12 (V)
P (*) *** (U)
**
––
1 2 3 4 5 6 7 8 9