FG/FCG-02 Model Series – Application Data
Functional Symbols
FCG–02
AB
AB
FG–02
General Information
FG/FCG valves provide precise
adjustable control of flow rates in
hydraulic circuits. They are pressure
and temperature compensated to
minimize flow variation resulting from
changes in fluid pressure and
temperature. They can be used in
meter-in, meter-out and bleed-off
circuits, and are completely
interchangeable with previous designs.
Application Guidance
Flow Adjustment
Flow rate is adjusted by rotating the dial.
A lettered (“A” through “E” ) indicator
marks approximately 4 1/2 revolutions,
from a fully closed to a fully opened
position.
Maximum throttle openings may be
limited by addition of spacers to the
throttle shaft under the selector dial.
Trim Adjustment
This optional feature permits an
adjustment of the flow setting when the
valve locking device is in a locked
position. Clockwise rotation increases
the flow, counterclockwise decreases
the flow.
Range of Adjustment
F*G–02–1500 & F*G–02–2300
8% of flow setting
F*G–02–300
3% of flow setting
Valve Locking
A standard key-locking device (2 keys
furnished) is supplied with these valves.
An optional device is also available.
Instead of using the key, the valve is
removed from its mounting to open the
access hole, which is on the front of the
valve. The valve is then returned to its
mounting and the new setting is made.
Then the access hole can be covered
using a screwdriver in the keyhole and
turning clockwise to trip the lock.
Subplate and Bolt Kits
Valves, subplates and mounting kits
must be ordered separately.
For example:
One (1) FG-02-1500-5* Valve
One (1) FGM-02-20 Subplate
One (1) FGM-02X-20 Subplate
One (1) BKFG-02-640 Mounting
Bolt Kit (Bolt length = 2 inch)
Maximum recommended mounting bolt
torque: 34,5 Nm (305 lb. in.)
Mounting bolts, when provided by a
customer, must be SAE grade 7,
or better.
Ratings
Maximum Flow Capacity (based on oil
viscosity of 150 SUS @ 100 F)
F*G-02-2300-* * -5
37690 cm
3
/min (2300 in
3
/min)
F*G-02-1500-* * -5
24580 cm
3
/min (1500 in
3
/min)
F*G-02-300-* * -5
4916 cm
3
/min (300 in
3
/min)
Nominal Reverse Free Flow
FCG-02-*- * * -5 only
56,7 lpm (15 USgpm)
Maximum Operating Pressure
248 bar (3600 psi)
Minimum Pressure Differential
Between Inlet and Outlet Ports
F*G-02-2300-* * -5
12 bar (175 psi)
F*G-02-1500-* * -5
10 bar (150 psi)
F*G-02-300-* * -5
7 bar (100 psi)
Pressure Drop
Pressure drop for reverse free flow over
check valve.
Volume lpm
(USgpm)
Pressure
bar (psi)
19 (5) 3 (45)
38 (10) 8 (120)
57 (15) 12 (175 )
76 (20) 20 (290)
95 (25) 30 (440)
NOTE: The pressures in the pressure drop
chart give approximate pressure drops (DP)
when passing a flow of 100 SSU fluids having
0.865 specific gravity.
For any other viscosity, the pressure drop
(DP) will change as follows:
Other Viscosity
% of DP from table
(approx.)
75 93
150 111
200 119
250 126
300 132
350 137
400 141
Specific gravity of fluid may be obtained
from its producer. For fire resistant
fluids, the value is higher than for oil.
Fluids and Seals
The use of synthetic fire-resistant fluids
requires a valve with special seals. Add
the prefix “F3” to the model number
when phosphate esters type fluids or its
blends are to be used with standard
seals. Refer to Vickers data sheet 694 ,
“Hydraulic Fluids and Temperature
Recommendations for Industrial
Machinery.
Weights
Valve 3.8 kg (8.5 lbs.). . . . . . . . . . . . . . .
Subplate 2.27 kg (5.0 lbs.). . . . . . . . . . .