EATON Screw-In Cartridge Valves E-VLSC-MC001-E December 2009H-160.A
An Eaton Brand
H
Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.
Ratings and Specifications
Figures based on oil temperature of 40˚ C and of 32 cSt (150 SUS)
Rated Flow 4 to 60 liters/min (1 to 16 USgpm)
Maximum pressure 350 bar (5000 psi)
Cartridge material All working parts hardened & ground steel.
Zinc plated body
Standard housing material Standard aluminum (up to 210 bar*)
Add suffix “377” for steel option
Mounting position Unrestricted
Cavity Number A7447 (See Section M)
Torque cartridge into cavity 75 Nm (55 ft lbs)
Weight 2CFRC60: 0,29 kg (0.64 lbs)
2CFRC65: 0,75 kg (1.65 lbs)
Seal kit number SK578 (Nitrile)
SK578V (Viton
®
)
Recommended Filtration Level BS5540/4 Class 18/13 (25 micron nominal)
Operating temperature –30° to +90°C (–22° to +194°F)
Nominal range 5 to 500 cSt
Viton is a registered trademark of E.I. DuPont
Operation
Flow into the inlet of the valve
passes through the adjustable
orifice and out of the regulated
port. The pressure drop across
the orifice is sensed on the
regulating sleeve and produces
a force which, at the required
flow rate, overcomes the
spring force. The resultant
movement of the sleeve
regulates the flow by closing
the radial valve ports.
The inbuilt check allows free
return of flow (2 to 1).
Features
Cartridge construction gives
versatility of application. A
valve may be fitted into a line
body, a custom designed
Hydraulic Integrated Circuit or
directly into a cylinder or other
actuator. Leakproof adjust
screw gives easy, accurate
adjustment to required flow
setting. Hardened and ground
working parts give accurate
flow control and long working
life.
Performance Data
2CFRC60 - Flow Regulator
Restrictive, pressure compensated with reverse check
4-60 L/min (1 to 16 USgpm) • 350 bar (5000 psi)
Sectional View
Description
This is a two-port, restrictive
flow regulator with a built in
free flow check valve. Typical
uses include the control of
actuator speed by regulating
the flow into or out of the
actuator (meter-in or
meter-out).
The flow (and actuator speed)
will be largely independent
of the load and the pressure
conditions. If used to restrict
flow from a fixed supply, for
example a standard gear or
piston pump, the valve will
pass the required flow and any
surplus flow will normally pass
over the system relief valve.
Pressure Drop Curves
Cartridge only
1
2
Load pressure - psi
Load pressure - bar
Regulated ow - US gpm
Regulated ow - litres/min
25
20
15
10
5
0
100
80
60
40
20
0
0 70 140 210 280 350
0 1000 2000 3000 4000 5000
eg (2)