Vickers
®
Vane Pumps
V Series - Low Noise Vane Pumps
High Performance Intravane Pumps
For Industrial Applications
There’s a certain energy at Eaton. It’s the power of integrating
the competencies of some of the world’s most respected
names to build a brand you can trust to meet every
power management need. The energy created supports
our commitment to powering business worldwide.
As the world’s demand for high-efficiency hydraulic
systems for mobile and stationary applications increase,
Eaton is helping to solve these challenges more reliably,
efficiently, and sustainably. Our goal is simple; to provide
unique solutions across a wide range of markets that
keep businesses on the leading edge of change. Visit
Eaton.com/hydraulics/fusion.
That’s the power of One Eaton.
The Power of One Eaton
HANSEN
GROMELLE
Eaton is a leading diversified
power management company
Understanding and helping our customers succeed
Listening and understanding to requirements and
business drivers
Delivering solutions with value propositions to solve the
critical business needs
Knowing what’s important to our customers and
integrating that knowledge into the fabric of our business
…to deliver innovative, quality products
• …to respond fast
…to provide dedicated customer service and support
around the globe
Our strength is global reach with local responsiveness
and support
Customers served in more than 150 countries
Diverse channels ensure reliable availability and support
Design and engineering teams provide support for
standard products and custom solutions
Eaton experts offer efcient product and application
training
Alternative Energy
Making energy sources technically
practical and economically sound
requires the kind of control
made possible by high-quality
components. When Eaton is on
the inside, you will experience the
reliable, consistent performance
to create and capture energy—
making renewable energy an
every-day energy.
Discrete Manufacturing
Produce at peak efficiency with
the superior precision and
repeatability of Eaton products.
Eaton hydraulic components
provide the precise control and
consistent operation required
for virtually every step in your
manufacturing operation. With
Eaton, we’ll help you redefine
the meaning of raw productivity.
Oil & Gas
As the oil & gas industry continues
to face further globalization
and consolidation, large-scale
organizations that can meet your
needs in every corner of the world
are more difficult to find. At Eaton,
our portfolio of products is only
surpassed by our tremendous
reach.
Processing
Whatever your industry, no matter
which processes you manage,
Eaton parts and systems help
keep you up and running. Our
components make equipment more
efficient and easier to use, so you
get optimal machine performance
and maximum productivity.
Agriculture & Forestry
Theres a reason farming and
forestry are called “working the
land.These segments involve
some of the hardest work and
longest hours of any sector in
the economy. Your productivity
and profitability depend on the
way you manage time and tasks.
Commercial Vehicles
Eaton technologies can make
your driving operation more
successful. Greater comfort
and productivity help increase
driver retention, while reduced
emissions, leaks, and noise
improve environmental
performance. Increased
efficiencies overall mean lower
costs and higher net revenue.
Material Handling
Eaton hydraulic systems provide
the precise control and
consistent operation required
for material handling and utility
work. With a broad selection of
products and solutions built in,
Eaton helps make you a master
of your domain.
Construction & Mining
When you work on a large scale,
even the details are big. You
need to trust every part of the
equipment that lets you handle
construction and mining jobs.
For reliable components that
deliver consistent performance in
extreme conditions, turn to Eaton.
Serving eight key segments - sharing one focus
Eaton provides reliable,
efficient and safe power
management for a growing
number of industries.
EATON Vickers
®
Vane Pumps V Series - Low Noise Vane Pumps 560 November 20114
Introduction
Vickers offers the most complete line of hydraulic intravane
pumps for industrial applications. A wide variety of single
and multiple configurations enables you to select the precise
pump or combination best suited for your application.
Your choice of pump is backed by more than 70 years of Vick-
ers engineering and manufacturing skill.
Performance
These cost–effective pumps provide volumetric efficiencies
of more than 90% and sound levels as low as 62 dB(A) with
operating pressures to 207 bar (3000 psi).
General Description
Intravane pumps provide longer life, increased productivity
and application versatility. Extremely low sound levels are
compatible with the most demanding industrial applications.
Compact size and ease of service allow maximum equipment
design flexibility. Pumps are available in single, double and
thru-drive configurations.
Features and Benefits
• High operating pressure capabilities in compact packages
provide high power to weight ratios and lower installed
costs.
• Low noise characteristics inherent in intravane design
enhance operator comfort.
• Twelve vane system provides low amplitude flow pulsa-
tions resulting in low system noise characteristics.
• Hydraulic balancing, designed to prevent internally-in-
duced radial shaft and bearing loads, provides long life.
• Double pumps and thru-drive arrangements save installa-
tion space and cost by eliminating double shaft extension
electric motors or by reducing the number of motors and
drive couplings.
• Thru-drive models provide valuable circuit design flex-
ibility, such as having fixed and variable displacement
models on a single input drive.
• Sixteen flow displacements and high operating pressure
capabilities provide optimum selection and single-source
capability for your complete range of flow and pressure
requirements.
• Factory tested cartridge kits provide new pump perfor-
mance upon installation.
• The cartridge kit design offers fast and efficient field ser-
viceability. The cartridge is independent of the drive shaft,
allowing for easy change of flow capacity and servicing
without removing the pump from its mounting.
• Inlet and outlet ports can be oriented in four different
positions relative to each other, providing greater installa-
tion flexibility and ease of machine design.
EATON Vickers
®
Vane Pumps V Series - Low Noise Vane Pumps 560 November 2011 5
Model Maximum Rated Maximum
Geometric Speed Pressure
Displacements r/min bar (psi)
cm
3
/r (in
3
/r)
Single Pumps Installation
20V 45 (2,8) 1800 207 (3000) ...................................... 21
25V 67 (4.1) 1800 172 (2500) ...................................... 22
35V 121 (7.4) 1800 172 (2500) ...................................... 22
45V 193 (11.7) 1800 172 (2500) ...................................... 22
Double Pumps Installation
2520V 67 (4.1) shaft end 1800 172 (2500) ...................................... 23
45 (2.8) cover end 1800 207 (3000)
2525V 67 (4.1) shaft end 1800 172 (2500) ...................................... 24
67 (4.1) cover end 1800 172 (2500)
3520V 121 (7.4) shaft end 1800 172 (2500) ...................................... 23
45 (2.8) cover end 1800 207 (3000)
3525V 121 (7.4) shaft end 1800 172 (2500) ...................................... 23
67 (4.1) cover end 1800 172 (2500)
4520V 193 (11.7) shaft end 1800 172 (2500) ...................................... 23
45 (2.8) cover end 1800 207 (3000)
4525V 193 (11.7) shaft end 1800 172 (2500) ...................................... 23
67 (4.1) cover end 1800 172 (2500)
4535V 193 (11.7) shaft end 1800 172 (2500) ...................................... 24
121 (7.4) cover end 1800 172 (2500)
Thru-Drive Pumps Installation
25VT 67 (4.1) 1800 172 (2500) ...................................... 26
35VT 121 (7.4) 1800 172 (2500) ...................................... 26
45VT 193 (11.7) 1800 172 (2500) ...................................... 26
Thru-drive Rear Mountings ........................................................................................................................... 27-30
Performance Data ......................................................................................................................................................................... 6
Model Code ................................................................................................................................................................................ 7-9
Operating Data ........................................................................................................................................................................... 10
Application Data ......................................................................................................................................................................... 11
Performance Characteristics ................................................................................................................................................ 12-20
Installation Data .................................................................................................................................................................... 21-30
Optional Shafts ...................................................................................................................................................................... 31-32
ISO Pilot Flange Mounting Options .......................................................................................................................................... 33
Torque Loading & Drives ........................................................................................................................................................... 34
Foot Mounting Bracket Option ................................................................................................................................................. 36
Weights & Mounting Options ................................................................................................................................................... 37
Ordering & Service Information ................................................................................................................................................ 37
Table of Contents
EATON Vickers
®
Vane Pumps V Series - Low Noise Vane Pumps 560 November 20116
Performance Data Single, Double &
Thru-Drive Vane Pumps
Pressure limits, inlet port - bar (psi):
Minimum -0,17 bar (5” Hg) for anti-wear oil
-0,10 bar (3” Hg) for water containing fluids
and phosphate esters
Maximum 1,4 bar (20 psi) all fluids
Range 0 to 0,35 bar (0 to 5 psi) all fluids
Maximum continuous pressures in bar (psi), outlet ports
Using anti-wear oil or Using water-in-oil Using water
Model Code phosphate ester fluid* emulsions glycol fluid
20V 2 138 (2000) 69 (1000) 138 (2000)
20V 5,8,11 207 (3000) 69 (1000) 159 (2300)
**20V 12 159 (2300) 69 (1000) 159 (2300)
**20V 14 138 (2000) 69 (1000) 138 (2000)
25V 10,12,14,17,21 172 (2500) 69 (1000) 159 (2300)
25VT 12,14,17,21 172 (2500) 69 (1000) 159 (2300)
25**V 12,14,17,21 172 (2500) 69 (1000) 159 (2300)
**25V 12,14,17,21 172 (2500) 69 (1000) 159 (2300)
35V 25,30,35,38 172 (2500) 69 (1000) 159 (2300)
35VT 25,30,35,38 172 (2500) 69 (1000) 159 (2300)
35**V 25,30,35,38 172 (2500) 69 (1000) 159 (2300)
**35V 25,30,35,38 172 (2500) 69 (1000) 159 (2300)
45V 42,45,50,60 172 (2500) 69 (1000) 159 (2300)
45VT 42, 50, 60 172 (2500) 69 (1000) 159 (2300)
45**V 42, 50, 60 172 (2500) 69 (1000) 159 (2300)
* A transient (peak) pressure 10% over the continuous pressure rating for 0.5 seconds or less duration is allowed.
Speed limits
Minimum speed, all models and fluid combinations ........................... 600 rpm
Maximum speed - standard models using anti-wear fluid ................... 1800 rpm
Standard models using synthetic and water-in-oil emulsions .............. 1200 rpm*
Models using water glycol fluid ........................................................... 1500 rpm*
* See Vickers brochure #579.
EATON Vickers
®
Vane Pumps V Series - Low Noise Vane Pumps 560 November 2011 7
Single Pump Model Code
F3 - Viton Seals
Omit if not required
Series Designation
20V – 7 to 45 cm
3
/r (0.43 to 2.78 in
3
/r)
25V – 33 to 67 cm
3
/r (2.0 to 4.1 in
3
/r)
35V – 81 to 121 cm
3
/r (4.9 to 7.4 in
3
/r)
45V – 138 to 193 cm
3
/r (8.4 to 11.6 in
3
/r)
Pilot Designation
Omit - Standard pilot
S – SAE per ISO 3019/1 (SAE J744)
(N/A on 20V pump).
M – Metric per ISO 3019/2 100A2HW
codes (N/A on 20V pump).
Geometric Displacement
Rated capacity (USgpm) at 1200 rpm,
6,9 bar (100 psi)
Frame Code
Size (USgpm) cm
3
/r in
3
/r
20V 2 7 0.43
5 18 1.10
8 27 1.67
9 30 1.85
11 36 2.22
12 40 2.47
14 45 2.78
25V 10 33 2.01
12 39 2.47
14 45 2.78
17 55 3.39
21 67 4.13
35V 25 81 4.94
30 97 5.91
35 112 6.83
38 121 7.37
45V 42 138 8.41
45 147 8.95
50 162 9.85
60 193 11.75
Port Connections
A – SAE 4-bolt flange
Port Connection Modifier
Omit – Inch thread port connection
(4-bolt flange).
M – Metric port connection
(4-bolt flange - N/A on 20V)
Mounting
Omit - Flange mounting
F – Foot mounting
Shafts
Std. Pilot Shafts
Str. HD Str.
Model Key Key Spline
20V 1 N/A 151
25V thru 45V 1 86 11
“S” SAE Pilot & “M” Metric ISO Pilot Shafts
HD Metric
Str. Str. Str.
Model Key Key Key Spline
25VS - 45VS 202 203 N/A 297
25VM - 45VM N/A N/A 292N N/A
Outlet Postions
(Viewed from cover end of pump)
A – Opposite inlet port
B – 90° CCW from inlet
C – Inline with inlet
D – 90° CW from inlet
Design
Rotation
(Viewed form shaft end of pump)
L – Left hand for counterclockwise
R – Right hand for clockwise
Special Suffix
167 – 2-bolt, 5.00” dia. pilot
(25V only - N/A for VS or VM
models)
1 4 7
8
9
10
11
12
5
6
2
3
(F3) - **V (M) ** A (M) (F) - * * 22 * - * * *
1 2 3 6 124 5 7 11108 9
Note: For options other than listed in the model code, i.e. shafts, ports,
displacements and mountings, contact your Vickers representative.
EATON Vickers
®
Vane Pumps V Series - Low Noise Vane Pumps 560 November 20118
Double Pump Model Code
F3 - Viton Seals
Omit if not required
Series Designation
Displacements cm
3
/r (in
3
/r)
Model Shaft End Cover End
2520V - 33 - 67 7 - 45
(2.0 - 4.1) (0.45 - 2.8)
2525V - (2.0 - 4.1) 33 - 67
(0.45 - 2.8) 33 - 67
3520V - (2.0 - 4.1) 81 - 121
(2.0 - 4.1) 7 - 45
3525V - (4.9 - 7.4) 81 - 121
(0.45 - 2.2) 33 - 67
4520V - (4.9 - 7.4) 138 - 193
(2.0 - 4.1) 7 - 45
4525V - (8.4 - 11.8) 138 - 193
(0.45 - 2.2) 33 - 67
4535V - (8.4 - 11.8) 138 - 193
(2.0 - 4.1) 81 - 121
(8.4 - 11.8) (4.9 - 7.4)
Pilot Designation
Omit - Standard pilot
S – SAE per ISO 3019/1 (SAE J744)
(N/A on 2525V)
M – Metric per ISO 3019/2 100A2HW
(N/A on 2525V)
Geometric Displacement -
Shaft End Pump
Rated capacity (USgpm) at 1200 rpm,
6,9 bar (100 psi)
Frame Code
Size (USgpm) cm
3
/r in
3
/r
25**V 10 33 2.0
12 40 2.5
14 45 2.8
17 55 3.4
21 67 4.1
35**V 25 81 4.9
30 97 5.9
35 112 6.8
38 121 7.4
45**V 42 138 8.4
45 147 9.0
50 162 9.9
60 193 11.8
Port Connections
A - SAE 4-bolt flange
Port Connection Modifier
Omit - Inch thread port connection
(4-bolt flange)
M - Metric port connection
(4-bolt flange)
Geometric Displacement -
Cover End Pump
Rated capacity (USgpm) at 1200 rpm,
6,9 bar (100 psi)
Frame Code
Size (USgpm) cm
3
/r in
3
/r
**20V 2 7 0.43
5 18 1.1
8 27 1.7
9 30 1.9
11 36 2.2
12 40 2.5
14 45 2.8
**25V 10 33 2.0
12 40 2.5
14 45 2.8
17 55 3.4
21 67 4.1
4535V 25 81 4.9
30 97 5.9
35 112 6.8
38 121 7.4
Mounting
Omit - Flange mounting
F – Foot mounting
Shaft
Std. Pilot Shafts
Str. HD Str.
Model Key Key Spline
25**V - 45**V 1 N/A 151
“S” SAE Pilot & “M” Metric
ISO Pilot Shafts
Str. HD Metric
Model Key Str. Key Str. Key Spline
25**VS - 45**VS 202 203 N/A 297
25**VM - 45**VM N/A N/A 292N N/A
Port Orientation
(Viewed from cover end of pump)
All series except 2525V & 4535V
With No. 1 outlet opposite inlet:
AA - No. 2 outlet 135 CCW from inlet
AB - No. 2 outlet 45 CCW from inlet
AC - No. 2 outlet 45 CW from inlet
AD - No. 2 outlet 135 CW from inlet
With No.1 outlet 90 CCW from inlet:
BA - No. 2 outlet 135 CCW from inlet
BB - No. 2 outlet 45 CCW from inlet
BC - No. 2 outlet 45 CW from inlet
BD - No. 2 outlet 135 CW from inlet
With No.1 outlet inline with inlet:
CA - No. 2 outlet 135 CCW from inlet
CB - No. 2 outlet 45 CCW from inlet
CC - No. 2 outlet 45 CW from inlet
CD - No. 2 outlet 135 CW from inlet
With No.1 outlet 90 CW from inlet:
DA - No. 2 outlet 135 CCW from inlet
DB - No. 2 outlet 45 CCW from inlet
DC - No. 2 outlet 45 CW from inlet
DD - No. 2 outlet 135 CW from inlet
Series 2525V & 4535V
With No.1 outlet opposite inlet:
AA - No. 2 outlet opposite inlet
AB - No. 2 outlet 90 CCW from inlet
AC - No. 2 outlet inline with inlet
AD - No. 2 outlet 90 CW from inlet
With No.1 outlet 90 CCW from inlet:
BA - No. 2 outlet opposite inlet
BB - No. 2 outlet 90 CCW from inlet
BC - No. 2 outlet inline with inlet
BD - No. 2 outlet 90 CW from inlet
With No.1 outlet inline with inlet:
CA - No. 2 outlet opposite inlet
CB - No. 2 outlet 90 CCW from inlet
CC - No. 2 outlet inline inlet
CD - No. 2 outlet 90 CW from inlet
With No.1 outlet 90 CW from inlet:
DA - No. 2 outlet opposite inlet
DB - No. 2 outlet 90 CCW from inlet
DC - No. 2 outlet inline with inlet
DD - No. 2 outlet 90 CW from inlet
Design
Rotation
(Viewed form shaft end of pump)
L – Left hand for counter clockwise
R – Right hand for clockwise
Special Suffix
167 – 2-bolt, 5” dia. pilot
(25**V only - N/A for VS or
VM models)
1 6
7
8
9
10
13
12
11
2
3
4
5
(F3) - ****V (M) ** A (M) ** (F) - * ** 22 * - ***
1 2 3 6 134 5 7 8 11 12109
Note: For options other than listed in the model code, i.e. shafts, ports,
displacements and mountings, contact your Vickers representative.
EATON Vickers
®
Vane Pumps V Series - Low Noise Vane Pumps 560 November 2011 9
Thru-Drive Pump Model Code
(F3) - **VT * S ** A (M) - 2 * * * 22 *
1 5 126 8 9 10 11 1373 42
F3 - Viton Seals
Omit if not required
Series Designation
25VT – 33 to 67 cm
3
/r (2.0 to 4.1 in
3
/r)
35VT – 81 to 121 cm
3
/r (4.9 to 7.4 in
3
/r)
45VT – 138 to 193 cm
3
/r
(8.4 to 11.8 in
3
/r)
Rear Pump Mounting
SAE (ISO 3019/1) 2-bolt
A – SAE “A”
B – SAE “B”
C - SAE “C” (35VT & 45VT only)
BP - SAE “B” to mount
PVE12/19/21 piston pump
Pilot Designation
M – Metric per ISO 3019/2 100A2HW
S – Standard pilot per ISO 3019/1
(SAE J744)
Geometric Displacement
Rated capacity (USgpm) at 1200 rpm,
6,9 bar (100 psi)
Frame Code
Size (USgpm) cm
3
/r in
3
/r
25VT 10 33 2.01
12 40 2.47
14 45 2.78
17 55 3.39
21 67 4.13
35VT 25 81 4.94
30 97 5.91
35 112 6.83
38 121 7.37
45VT 42 138 8.41
45 147 8.95
50 162 9.85
60 193 11.75
Port Connections
A – SAE 4-bolt flange
Port Connection Modifier
Omit – Inch thread port connection
(4-bolt flange).
M – Metric port connection
(4-bolt flange)
Thru-Drive Coupling
2 – Coupling with pump (included)
Pump Tail shaft pump
Series Requirements
**VTA SAE “A” size w/30 involute
spline, 9T 16/32 D.P.
**VTB SAE “B” size w/30 involute
spline, 13T 16/32 D.P.
**VTC SAE “C” size w/30 involute
spline, 14T 12/24 D.P.
Shaft
SAE Str. ISO Str. SAE HD Str.
Model Key Key Spline Key
25VT 202 292N 297 203
35VT N/A 292N 297 203
45VT N/A 292N 297 203
Outlet Postions
(Viewed from cover end of pump)
A – Opposite end
B – 90° CCW from inlet
C – Inline with inlet
D – 90° CW from inlet
Thru-Drive Adapter Orientation
(Viewed from cover end of pump)
SAE - A Adaptor
A - Rotate 45° CW with respect to
pump mounting flange
B - Rotate 45° CCW with respect to
pump mounting flange
SAE - B, BP or C adaptor
A – Inline with pump mounting flange
B – Rotate 90 with respect to pump
mounting flange
Design
Rotation
(Viewed form shaft end of pump)
L – Left hand for counterclockwise
R – Right hand for clockwise
1 6
7
8
10
11
12
13
9
2
3
4
5
Note: For options other than listed in the model code, i.e. shafts, ports,
displacements and mountings, contact your Vickers representative.
EATON Vickers
®
Vane Pumps V Series - Low Noise Vane Pumps 560 November 201110
Operating Data
Sound Levels
Average sound levels are at
138 bar (2000 psi) using SAE
10W (26 cSt) – (128 SUS) oil
at 50°C (120°F).
- dB(A) -
1200 1500 1800
Model rpm rpm rpm
20V 62 64 66
25V 63 65 67
35V 64 66 69
45V 67 69 71
Sound levels for double
pumps are on the average 1
to 3 dB(A) higher when both
pumping sections are pres-
surized.
Sound levels are per NFPA
T3.970.12 test standards.
Hydraulic Fluids
Use antiwear industrial
hydraulic oils or automotive
crankcase oils having letter
designations SC, SD, SE or
SF with viscosity grades of
32 to 68 cSt at 40° C (140°
F). Preferred viscosity at
rated speed and pressures:
Minimum 13 cSt (70 SUS)
Maximum 54 cSt (251 SUS)
Minimum 49°C (120°F)
Maximum 65°C (150°F)
Cold Starts
When operating with SAE
10W oil in the 860 to 54 cSt
(4000 to 251 SUS) range, the
speed and pressure should
be limited to 50% or less of
their respective rated values
until the system has warmed
up. Extreme caution must
be used when starting units
when fluid viscosities are
greater than 860 cSt (4000
SUS). Care should be exer-
cised to warm up the entire
system, including remote
cylinders and motors.
High Temperature
Viscosities must not be less
than the respective minimum
values listed for each series
of pumps. Temperatures
should not exceed 99° C
(210° F) because the life ex-
pectancy of cartridge kits and
elastomers will decrease.
Water-in-oil Emulsions
Water-in-oil emulsions may
be used. However, they
require careful selection and
monitoring of the fluid. For
assistance contact your Vick-
ers representative. Soluble
oil-in-water solutions are not
recommended.
Synthetic Fire Resistant Fluids
Phosphate esters and their
blends with operating viscos-
ity of the petroleum oil de-
scribed above may be used.
These fluids are generally
compatible with fluorocarbon
and silicone elastomers. Add
F3 prefix to the model code
for special seals.
For operating conditions
exceeding recommendations
listed in this section, consult
your Vickers representative.
For details, refer to Vickers
data sheet I-286-S, M-2950-S
or GB-B-920, “Hydraulic Fluid
and Temperature Recom-
mendations.”
Filtration Requirements
For satisfactory service life of
components, use full flow fil-
tration to provide fluid cleanli-
ness conforming to ISO code
(see next page). Vickers OFP,
OFR and OFRS series filters
are recommended. Contact
your Vickers representative
for further filtration advice.
Drive Data
Pumps are assembled for
CW or CCW rotation. Right
hand or clockwise rotation
and left hand or counterclock-
wise rotation is viewed from
the shaft end.
Inlet and outlet ports remain
the same regardless of the
direction of shaft rotation.
Assembly change of internal
parts is necessary, when
change of shaft rotation is
required.
Pump Drive
Direct coaxial drive is recom-
mended. If drives imposing
radial shaft loads are con-
sidered, please consult your
Vickers representative.
Air Bleed
At the time of first-starting,
if the pump does not im-
mediately prime, air should
be bled from the pump
delivery line. This may be
accomplished by loosening
a connection in the deliv-
ery line close to the pump
until oil flows – indicating
the pump has primed. An air
bleed valve is available for
this purpose.
CAUTION: – No Case Drain The
pump is drained internally into its
inlet. System pressure at the pump
inlet connection may not exceed 1,4
bar (20 psi).
CAUTION: – Low Outlet Pressure Do
not run a pump with the outlet pres-
sure lower than the inlet pressure.
This causes operating noise and
vane instability.
Start-up Procedure
Make sure the reservoir and
circuit are clean and free of
dirt/debris prior to filling with
hydraulic fluid.
Fill the reservoir with filtered
oil and fill to a level sufficient
enough to prevent vortex-
ing at suction connection to
pump inlet. It is good practice
to clean up the system by
flushing and filtering using an
external slave pump.
Before starting the pump,
fill with fluid through one
of the ports. This is particu-
larly important if the pump is
above the fluid level of the
reservoir.
When initially starting the
pump, remove all trapped air
from the system. This can be
accomplished by loosening
the pump outlet fittings or
connections before starting
the pump or by using an air
bleed valve. All inlet con-
nections must be tight to
prevent air leaks.
Once the pump is started it
should prime within a few
seconds. If the pump does
not prime, check to make
sure that there are no restric-
tions between the reservoir
and the inlet to the pump,
and that there are no air leaks
in the inlet line and connec-
tions. Also check to make
sure that trapped air can
escape at the pump outlet.
After the pump is primed,
tighten the loose outlet con-
nections, then operate for
five to ten minutes unloaded
to remove all trapped air from
the circuit.
If reservoir has a sight gage,
make sure the fluid is clear –
not milky.
Add fluid to the reservoir to
bring it up to the proper fill
level.
EATON Vickers
®
Vane Pumps V Series - Low Noise Vane Pumps 560 November 2011 11
Application Data
Fluid Cleanliness
Proper fluid condition is essential for long and satisfactory
life of hydraulic components and systems. Hydraulic fluid
must have the correct balance of cleanliness, materials, and
additives for protection against wear of components, elevated
viscosity, and inclusion of air.
Essential information on the correct methods for treating
hydraulic fluid is included in Vickers publication 561 “Vickers
Guide to Systemic Contamination Control” available from
your local Vickers distributor or by contacting Vickers, Incor-
porated. Recommendations on filtration and the selection of
products to control fluid condition are included in 561.
Recommended cleanliness levels, using petroleum oil under
common conditions, are based on the highest fluid pressure
levels in the system and are coded in the chart below. Fluids
other than petroleum, severe service cycles, or temperature
extremes are cause for adjustment of these cleanliness
codes. See Vickers publication 561 for exact details.
Vickers products, as any components, will operate with ap-
parent satisfaction in fluids with higher cleanliness codes
than those described. Other manufacturers will often recom-
mend levels above those specified. Experience has shown,
however, that life of any hydraulic component is shortened in
fluids with higher cleanliness codes than those listed below.
These codes have been proven to provide a long, trouble-free
service life for the products shown, regardless of the manu-
facturer.
Fluids and Seals
Flourocarbon seals are available and are suitable for use with
phosphate ester type fluids or their blends, water glycol,
water-in-oil emulsion fluids and petroleum oil.
Product System Pressure Level bar (psi)
<70 ( <1000) 70-207 (1000-3000) 207+ ( 3000+)
Vane Pumps – Fixed 20/18/15 19/17/14 18/16/13
Vane Pumps – Variable 18/16/14 17/15/13
Piston Pumps – Fixed 19/17/15 18/16/14 17/15/13
Piston Pumps – Variable 18/16/14 17/15/13 16/14/12
Directional Valves 20/18/15 20/18/15 19/17/14
Pressure/Flow Control Valves 19/17/14 19/17/14 19/17/14
CMX Valves 18/16/14 18/16/14 17/15/13
Servo Valves 16/14/11 16/14/11 15/13/10
Proportional Valves 17/15/12 17/15/12 15/13/11
Cylinders 20/18/15 20/18/15 20/18/15
Vane Motors 20/18/15 19/17/14 18/16/13
Axial Piston Motors 19/17/14 18/16/13 17/15/12
Radial Piston Motors 20/18/14 19/17/13 18/16/13
EATON Vickers
®
Vane Pumps V Series - Low Noise Vane Pumps 560 November 201112
20V Performance Characteristics
20V Cartridge Performance
Typical flows at 50° C (120° F), 10W oil (26cSt) - (128 SUS),
0 psi inlet at specified speeds
EATON Vickers
®
Vane Pumps V Series - Low Noise Vane Pumps 560 November 2011 13
20V Performance Characteristics
20V Cartridge Performance
Typical flows at 50° C (120° F), 10W oil (26cSt) - (128 SUS),
0 psi inlet at specified speeds
EATON Vickers
®
Vane Pumps V Series - Low Noise Vane Pumps 560 November 201114
20V Performance Characteristics
EATON Vickers
®
Vane Pumps V Series - Low Noise Vane Pumps 560 November 2011 15
25V(T), 25**V, & **25V
Performance Characteristics
EATON Vickers
®
Vane Pumps V Series - Low Noise Vane Pumps 560 November 201116
25V(T), 25**V, & **25V
Performance Characteristics
EATON Vickers
®
Vane Pumps V Series - Low Noise Vane Pumps 560 November 2011 17
35V(T), 35**V, & **35V
Performance Characteristics
EATON Vickers
®
Vane Pumps V Series - Low Noise Vane Pumps 560 November 201118
35V(T), 35**V, & **35V
Performance Characteristics
EATON Vickers
®
Vane Pumps V Series - Low Noise Vane Pumps 560 November 2011 19
45V(T), 45**V
Performance Characteristics
EATON Vickers
®
Vane Pumps V Series - Low Noise Vane Pumps 560 November 201120
45V(T), 45**V
Performance Characteristics
EATON Vickers
®
Vane Pumps V Series - Low Noise Vane Pumps 560 November 2011 21
20V Installation Dimensions
20V Series Single Pumps
Millimeters (inches)
For mounting bracket dimensions see page 36.
2,36
(.093)
17,9
(.07)
35,7
(1.41)
(.875)
1,11
(.44)
47,6
(1.87)
23,8
(.94)
.375-16 UNC-2B or M10-.750 thd., 4 holes
Uses FL1-6 series flange.
34,9
(1.38)
70
(2.75)
101,6 (4.00)
101,5 (3.99)
19 (.75) outlet
.500-13 UNC-2B 21 (.83) deep, 4 holes.
Uses FL1-12 series flange.
38,1 (1.50)
inlet
C
D
A
B
Alternate cover positions
76,2
(3.0)
55,4
(2.2)
50,8
(2.0)
155,4
(6.12)
132,6
(5.22)
63,5
(2.5)
For shaft options see pages 31 & 32 .
58,7
(2.31)
9,5
(.375)
27,9 (1.10)
27,6 (1.09)
22,3 (.875)
22,2 (.874)
#1 Shaft shown
25,5 (.966)
24,4 (.961)
4,75 x 31.5
(.187 x 1.25)
key
12,7
(.50)
146
(5.75)
14,2
(.56)
through 2 holes
EATON Vickers
®
Vane Pumps V Series - Low Noise Vane Pumps 560 November 201122
25V, 35V, 45V
Installation Dimensions
Model ø F x full thread ø K x full thread
depth, 4 holes depth, 4 holes
25V(*)-**AM M10 x 19,0 (0.75)) deep M12 x 23,8 (0.94) deep
25V(*)-**A
3
8”-16UNC-2B x 19 (0.75) deep
1
2”-13UNC-2B x 23,8 (0.94) deep
35V(*)-**AM M12 x 22,3 (0.88) deep M12x22,3 (0.88) deep
35V(*)-**A 0.43”-14UNC-2B x 22,3 (0.88)deep
1
2 ”-13UNC-2B x 22,3 (0.88) deep
45V(*)-**AM M12 x 23,8 (0.94) deep M16 x 30 (1.18) deep
45V(*)-**A
1
2”-13UNC-2B x 23,8 (0.94) deep
5
8”-11UNC-2B x 30 (1.18) deep
L for (**VS P for P for
Model A B øC D E øG H J L & **VM) M øN P (**VS) (**VM)
25V 35,7 26,2 25,4 52,4 12,7 38,1 118 69,9 121 149 38,1 101,6 (4.00) 9,53 9,53 9,25
(1.41) (1.03) (1.00) (2.06) (0.50) (1.50) (4.62) (2.75) (4.76) (5.88) (1.50) 101,5 (3.99) (0.38) (0.38) (.364)
35V 42,9 30,2 31,8 58,7 16 50,8 140 77,8 125,5 133,4 38,1 127,0 (5.00) 9,53 12,7 9.11
(1.69) (1.19) (1.25) (2.31) (0.63) (2.00) (5.50) (3.06) (4.94) (5.25) (1.50) 126,9 (4.99) (0.38) (0.50) (.359)
45V 61,9 35,7 38,1 69,9 16 76,2 159 106,4 153 164 43 127,0 (5.00) 12,7 12,7 9.11
(2.43) (1.41) (1.50) (2.75) (0.63) (3.00) (6.25) (4.19) (6.03) (6.44) (1.69) 126,9 (4.99 (0.50) (0.50) (.359)
Model Q Q for (**VS) Q for (**VM) R S øT RU øV øW øX
25V 162,1 171,7 171,7 63,5 76,2 146 14 14,2 175 121
(6.38) (6.76) (6.76) (2.50) (3.00) (5.75) (0.55) (0.56) (6.88) (4.76)
35V 185 193 193 69,9 82,6 181 16 17,5 213 148
(7.28) (7.59) (7.59) (2.75) (3.25) (7,13) (0.63) (0.69) (8.38) (5.83)
45V 216 226 226 82,6 93,7 181 16 17,5 213 148
(8.50) (8.91) (8.91) (3.25) (3.69) (7.13) (0.63) (0.69) (8.38) (5.83)
Millimeters (inches)
25V, 35V and 45V Single Pumps
HJ
K
A
B
Outlet C, SAE flange pad with 4 mounting holes.
F:
25V pumps use FL-8 flange
35V pumps use FL-10 flange
45V pumps use FL-12 flange
D
Inlet G, SAE flange pad with
four mounting holes.
K:
25V pumps use FL-12 flange
35V pumps use FL-16 flange
45V pumps use FL-24 flange
F
W
X
S
R
N
Q
L
M
P
For shaft options see pages 31 & 32.
For metric pilot flange dimensions see page 33
V
T
RU
E
For mounting bracket dimensions see page 36.
EATON Vickers
®
Vane Pumps V Series - Low Noise Vane Pumps 560 November 2011 23
2520V, 35**V, 452*V
Installation Dimensions
G for G for
Model A B C øD E øF G (****VS) (****VM) øH J øK øL M N
2520V 50,8 26,2 12,7 25,4 52,4 101,6 (4.0) 9,53 9,53 9,25 63,5 88,9 19,1 14,2 76,2 88,1
(2.00) (1.03) (0.50) (1.00) (2.06) 101,5 (3.9) (0.38) (0.38) (.364) (2.50) (3.50) (0.75) (0.56) (3.00) (3.47)
3520V 62 30,1 15,9 31,7 58,7 127 (5.00) 9,53 12,7 9,12 76,2 106,3 19,1 17,5 76,2 99,6
(2.44) (1.19) (0.62) (1.25) (2.31) 126 (4.99) (0.38) (0.50) (.359) (3.00) (4.19) (0,75) (0.69) (3.00) (3.92)
3525V 62 30,1 15,9 31,7 58,7 127 (5.00) 9,53 12,7 9,12 76,2 106,3 25,4 17,5 74,7 109,5
(2.44) (1.19) (0.62) (1.25) (2.31) 126 (4.99) (0.38) (0.50) (.359) (3.00) (4.19) (1.00) (0.69) (2.94) (4.31)
4520V 69,9 35,7 15,9 38,1 69,9 127 (5.00) 12,7 12,7 9,12 88,9 120,6 19,1 17,5 76,2 102
(2.75) (1.41) (0.62) (1.50) (2.75) 126 (4.99) (0.50) (0.50) (.359) (3.50) (4.75) (0.75) (0.69) (3.00) (4.72)
4525V 69,9 35,7 15,9 38,1 69,9 127 (5.00) 12,7 12,7 9,12 88,9 120,6 25,4 17,5 74,7 136
(2.75) (1.41) (0.62) (1.50) (2.75) 126 (4.99) (0.50) (0.50) (.359) (3.50) (4.75) (1.00) (0.69) (2.94) (5.35)
P for (***VS S for S for
Model P & VM) Q R S (***VS) (***VM) T øU øV RW øX Y Z
2520V 101,6 111,3 (4.38) 38,1 76,2 250 259 259 85,3 146,1 175 14 174,7 22,2 47,6
(4.00) (1.50) (3.00) (9.81) (10.2) (10.2) (3.38) (5.75) (6.88) (0.55) (6.88) (0.88) (1.88)
3520V 114,3 122,2 (4.81) 38,1 82,6 273,3 285 282 88,9 181 148 16 213 22,2 47,6
(4.50) (1.50) (3.25) (10.8) (11.2) (11.1) (3.50) (7.13) (5.83) (0.63) (8.38) (0.88) (1.88)
3525V 114,3 122,2 (4.81) 38,1 82,6 287,3 260 254 88,9 181 148 16 213 26,2 52,4
(4.50) (1.50) (3.25) (9.81) (10.2) (10.0) (3.50) (7.13) (5.83) (0.63) (8.38) (1.03) (2.06)
4520V 119,4 129,7 (5.11) 42,9 93,7 303,5 314 310 102,4 181 148 16 213 22,2 47,6
(4.70) (1.69) (3.69) (11.95) (12.4) (12.2) (4.03) (7.13) (5.83) (0.63) (8.38) (0.88) (1.88)
4525V 119,4 129,7 (5.11) 42,9 93,7 325 336 332 102,4 181 148 16 213 26,2 52,4
(4.70) (1.69) (3.69) (12.8) (13.2) (13.1) (4.03) (7.13) (5.83) (0.63) (8.38) (1.03) (2.06)
Nominal port size, also see next page “port flange kits and mountings for double pumps.
Millimeters (inches)
Outlet No. 2 K
D
45
2520V, 35**V and 452*V Double Pumps
A
M
EJ
F
G
See port flange kits and mountigs for
double pumps on page 25.
Outlet No. 1 D
Inlet H
B
C
L
Z
Y
For shaft options see pages 31 & 32.
S
NP Q
R
T
V
X
U
RW
For mounting bracket dimensions see page 36.
EATON Vickers
®
Vane Pumps V Series - Low Noise Vane Pumps 560 November 201124
2525V, 4535V
Installation Dimensions
Model A B C øD E øF G øH J øK øL M N
2525V 50,8 26,2 12,7 25,4 52,4 101,6 (4.0) 9,53 63,5 88,9 25,4 14,2 76,2 97,5
(2.00) (1.03) (0.50) (1.00) (2.06) 101,5 (3.9) (0.38) (2.50) (3.50) (1.00) (0.56) (3.00) (3.84)
4535V 77,8 35,7 15,9 38,1 69,9 127 (5.00) 12,7 101,6 130,2 31,7 17,5 101,6 148,3
(3.06) (1.41) (0.62) (1.50) (2.75) 126 (4.99) (0.50) (4.00) (5.13) (1.25) (0.69) (4.00) (5.84)
4535VM 9,12
(.359)
Model P Q R S T øU øV RW øX Y Z
2525V 101,6 38,1 76,2 263 84 146,1 175 14 174,7 26,2 52,4
(4.00) (1.50) (3.00) (10.4) (3.31) (5.75) (6.88) (0.55) (6.88) (1.03) (2.06)
4535V 133,3 42,9 93,7 353 102,4 181 148 213 30,2 58,7
(5.25) (1.69) (3.69) (13.9) (4.03) (7.13) (5.83) (8.38) (1.19) (2.31)
4535VS & 144 364
4535VM (5.66) (14.3)
Millimeters (inches)
2525V and 4535V Series Double Pumps
Outlet No. 2 K
See port flange kits and mountigs for
double pumps on the next page.
Inlet H
A
B
Outlet No. 1 D
E
F
B
J
Z
Y
M
T
NP Q
148
(5.83)
X
U
R
S
G
C
L
Outlet No. 2
1.31 -12 UNC-2B str. thds.
Outlet No. 1
1.31 -12 UNC-2B
str. thds.
For mounting bracket dimensions see page 36.
For shaft options see pages 31 & 32.
Nominal port size, also see next page port flange kits and mountings for double pumps.
EATON Vickers
®
Vane Pumps V Series - Low Noise Vane Pumps 560 November 2011 25
Port Flange Kits /Mtg
for Double Pumps
Pump Inlet Outlet No. 1, Shaft end Outlet No. 2, Rear end
Mounting Bolt Tap Mounting Bolt Tap Mounting Bolt Tap
& Full Thread & Full Thread & Full Thread
Flange Kits Depth Flange Kits Depth Flange Kits Depth
2520V-**AM- N/A from Vickers M12 x 23,8 (0.94) N/A from Vickers M10 x 20,1 (0.79) N/A from Vickers M10 x 20,1 (0.79)
2520V-**A- FL1-20- .50” - 13UNC-2B x FL1-8- .375” - 16UNC-2B x FL1-6 .375” - 16UNC-2B x
23,8 (0.94) 20,1 (0.79) 20,1 (0.79)
2525V-**AM- N/A from Vickers M12 x 23,8 (0.94) N/A from Vickers M10 x 20,1 (0.79) N/A from Vickers M10 x 20,1 (0.79)
2525V-**A- FL1-20- .50” - 13UNC-2B x FL1-8- .375” - 16UNC-2B x FL1-8- .375” - 16UNC-2B x
23,8 (0.94) 20,1 (0.79) 20,1 (0.79)
3520V-**AM- N/A from Vickers M16 x 30,0 (1.18) N/A from Vickers M16 x 30,0 (1.18) N/A from Vickers M10 x 20,1 (0.79)
3520V-**A- FL1-24- .625” - 11UNC-2B x FL1-10- .437” - 14UNC-2B x FL1-6- .375” - 16UNC-2B x
30,0 (1.18) 30,0 (1.18) 20,1 (0.79)
3525V-**AM- N/A from Vickers M16 x 30,0 (1.18) N/A from Vickers M16 x 30,0 (1.18) N/A from Vickers M10 x 20,1 (0.79)
3525V-**A- FL1-24- .625” - 11UNC-2B x FL1-10- .437” - 14UNC-2B x FL1-8- .375” - 16UNC-2B x
30,0 (1.18) 30,0 (1.18) 20,1 (0.79)
4520V-**AM- N/A from Vickers M16 x 30,0 (1.18) N/A from Vickers M12 x 23,8 (0.94) N/A from Vickers M10 x 20,1 (0.79)
4520V-**A- FL1-28- .625” - 11UNC-2B x FL1-12- .50” - 13UNC-2B x FL1-6- .375” - 16UNC-2B x
30,0 (1.18) 23,8 (0.94) 20,1 (0.79)
4525V-**AM- N/A from Vickers M16 x 30,0 (1.18) N/A from Vickers M12 x 23,8 (0.94) N/A from Vickers M10 x 20,1 (0.79)
4525V-**A- FL1-28- .625” - 11UNC-2B x FL1-12- .50” - 13UNC-2B x FL1-8- .375” - 16UNC-2B x
30,0 (1.18) 23,8 (0.94) 20,1 (0.79)
4535V-**AM- N/A from Vickers M16 x 30,0 (1.18) N/A from Vickers M12 x 23,8 (0.94) N/A from Vickers M10 x 20,1 (0.79)
4535V-**A- FL1-32- .625” - 11UNC-2B x FL1-12- .50” - 13UNC-2B x FL1-10- .437” - 14UNC-2B x
30,0 (1.18) 23,8 (0.94) 30,0 (1.18)
Port Flange Kits and Mountings for Double Pumps
EATON Vickers
®
Vane Pumps V Series - Low Noise Vane Pumps 560 November 201126
**VT Thru Drives
Installation Dimensions
Model A B C øD E F G øH J K L M N
25VT See 111,1 38,1 174,8 87,4 76,2 84,1 101,6 (4.00) 52,4 26,2 50,8 88,9 44,5
page . (4.38) (1.50) (6.88) (3.44) (3.00) (3.31) 101,5 (3.99) (2.06) (1.03) (2.00) (3.50) (1.75)
35VT See 122 38,1 213 106,2 82,6 88,9 127,0 (5.00) 58,7 29,4 61,9 106,4 53,2
page . (4.81) (1.50) (8.38) (4.18) (3.30) (3.50) 126,9 (4.99) (2.31) (1.16) (2.44) (4.19) (2.09)
45VT See 129,9 42,9 213 106,2 93,7 102,3 127,0 (5.00) 69,9 34,9 69,9 120,7 60,3
page . (5.11) (1.69) (8.38) (4.18) (3.69) (4.03) 126,9 (4.99) (2.75) (1.38) (2.75) (4.75) (2.38)
Model P Q R S T U øV øW øX Y øZ AA
25VT 9,52 12,7 26,2 13,1 25,4 73 146 120,6 63,5 .500-13 UNC-2B 25,4 .375-16 UNC-2B
(0.375) (0.50) (1.03) (0.52) (1.00) (2.88) (5.75) (4.75) (2.50) or M12 thd. 23,8 (1.00) or M16 thd. 20,1
(.938) deep (0.79) deep
4 holes 4 holes
35VT 12,5 15,7 30,2 15,1 30,9 90,5 180,9 147,6 76,2 .625-11 UNC-2B 31,8 .437-14 UNC-2B
(0.49) (0.62) (1.19) (0.59) (1.22) (3.56) (7.13) (5.81) (3.00) or M16 thd. 30,0 (1.25) or M16 thd. 30,0
(1.18) deep (1.18) deep
4 holes 4 holes
45VT 12,5 15,7 35,7 17,9 35,9 90,5 181 147,6 88,9 .625-11 UNC-2B 38,1 .500-13 UNC-2B
(0.49) (0.62) (1.41) (0.70) (1.38) (3.56) (7.13) (5.81) (3.50) or M16 thd. 30,0 (1.50) or M12 thd. 22,2
(1.18) deep (.875) deep
4 holes 4 holes
T
U
V
W
X Inlet port
Z Outlet port
For shaft options see pages 31 & 32.
27 & 30.
33.
EATON Vickers
®
Vane Pumps V Series - Low Noise Vane Pumps 560 November 2011 27
**VT Thru–Drive Rear Mountings
Installation Dimensions
Dimension “A
Pump Dimension
Model **VTAS Models **VTAM Models “L”*
32,6/31,0
(1.28/1.22)
33,0 (1.30)
25VTA 236,5 (9.3) 236,5 (9.3) Maximum
32,6/31,0
(1.28/1.22)
35,6 (1.40)
35VTA 259,1 (10.2) 259,1 (10.2) Maximum
32,6/31,0
(1.28/1.22)
35,3 (1.39)
45VTA 291,6 (11.5) 321,8 (12.7) Maximum
* Caution: Dimension “L” is important and must be observed.
NOTE: This unit accepts a hydraulic pump which conforms to flange and
shaft codes specified in ISO 3019/1 (SAE J744 JuI88).
**VTA
The following Vickers shaft selection will comply with the
above:
Flange Shaft SAE
Code Code J744C (Ref)
82-2 16-4 A
Rear Pump
Model Shaft
V10 Vane pump 11
V20 Vane pump 62
PVB5/6 Piston pump S124
EATON Vickers
®
Vane Pumps V Series - Low Noise Vane Pumps 560 November 201128
**VT Thru–Drive Rear Mountings
Installation Dimensions
Dimension “A
Pump Dimension
Model **VTBS Models **VTBM Models “L”*
42,3/39,9
(1.67/1.57)
45,2 (1.78)
25VTB 245,8 (9.67) 245,8 (9.67) Maximum
42,3/39,9
(1.67/1.57)
46,7 (1.84)
35VTB 268,2 (10.56) 268,2 (10.56) Maximum
42,3/39,9
(1.67/1.57)
46,2 (1.82)
45VTB 300,7 (11.84) 331,0 (13.03) Maximum
* Caution: Dimension “L” is important and must be observed.
NOTE: This unit accepts a hydraulic pump which conforms to flange and
shaft codes specified in ISO 3019/1 (SAE J744 JuI88).
**VTB
The following Vickers shaft selection will comply with the
above:
Flange Shaft SAE
Code Code J744C (Ref)
101-2 22-4 B
Rear Pump
Model Shaft
PVB10/15 Piston pump S124
V2010/2020 Double pump 11
20V Vane pump 151
25V Vane pump 11
2520V Double pump 11
EATON Vickers
®
Vane Pumps V Series - Low Noise Vane Pumps 560 November 2011 29
**VT Thru–Drive Rear Mountings
Installation Dimensions
Dimension “A
Pump Dimension
Model **VTBPS **VTBPM “L”*
45,6/43,2
(1,80/1.70)
25VTBP 261,9 (10,31) 261,9 (10,31) Not SAE std.
45,6/43,2
(1,80/1.70)
35VTBP 284,5 (11,20) 284,5 (11,20) Not SAE std.
45,6/43,2
(1,80/1.70)
45VTBP 317,0 (12.48) 347,2 (13,67) Not SAE std.
* Caution: Dimension “L” is important and must be observed.
NOTE: These units accept a Vickers pump as below which conforms to
flange code 101-2 in ISO 3019/1 (SAE J744C Ju188) and has a Vickers
type 9 shaft
**VTBP
The following Vickers shaft selection will comply with the
above:
Rear Pump
Model Shaft
PVE12/19/21 Piston pump 9
EATON Vickers
®
Vane Pumps V Series - Low Noise Vane Pumps 560 November 201130
**VT Thru Drive Rear Mountings
Installation Dimensions
Dimension “A
Pump Dimension
Model **VTCS Models **VTCM Models “L”*
56,6/54,2
(2,23/2,13)
61,2 (2.41)
35VTC 275,8 (10,86) 275,8 (10,86) Maximum
56,6/54,2
(2,23/2,13)
61,5 (2.42)
45VTC 308,4 (12,14) 338,6 (13,33) Maximum
* Caution: Dimension “L” is important and must be observed.
NOTE: This unit accepts a hydraulic pump which conforms to flange and
shaft codes specified in ISO 3019/1 (SAE J744 JuI88),
**VTC
The following Vickers shaft selection will comply with the
above:
Flange Shaft SAE
Code Code J744C (Ref)
127-2 32-4 C
Rear Pump
Model Shaft
35V Vane pump 11
3520/3525V Double pumps 11
45V Vane pump 11
EATON Vickers
®
Vane Pumps V Series - Low Noise Vane Pumps 560 November 2011 31
Optional Shafts
Straight Key Shafts
Thru-drive shafts, see pages 34.
Pump Shaft F key width
Code A B C øD E x length
20V 1 59 (2.32) 9,53 (.375) 12,1 (.476) 22,23 (.875) 24,5 (.966) 4,75 (.817)
22,20 (.874) 24,4 (.961) x 32 (1.25)
25V 1 59 (2.32) 9,53 (.375) 11,1 (.435) 22,23 (.875) 24,5 (.966) 4,75 (.817)
2520V 22,20 (.874) 24,4 (.961) x 32 (1.25)
25V 86 78 (3.06) 9,53 (.375) 11,1 (.435) 25,37 (.999) 28,3 (1.11) 6,36 (.250)
252*V 25,35 (.998) 28,1 (1.10) x 50,8 (2.00)
25VM 292N 52,3 (2.06) 9,25 (.364) 10,4 (.41) 25,02 (.985) 28,02 (1.10) 8,00 (.314)
252*VM 25,00 (.984) 27,81 (1.09) x 28 (1.10)
25VT*M
25VT*S 202 71,4 (2.81) 9,53 (.375) 7,9 (.310) 22,23 (.875) 25,15 (.990) 6,36 (.250)
25VS 22,20 (.874) 24,90 (.980) x 50,8 (2.00)
252*VS 203 77,7 (3.06) 9,53 (.375) 7,9 (.310) 25,40 (1.00) 28,20 (1.11) 6,36 (.250)
25,35 (.998) 27,94 (1.10) x 50,8 (2.00)
35V 1 73,2 (2.88) 9,53 (.375) 11,1 (.435) 31,75 (1.25) 35,36 (1.39) 7,94 (.313)
352*V 31,70 (1.24) 34,10 (1.38) x 38,1 (1.50)
86 86 (3.88) 9,53 (.375) 11,1 (.435) 34,90 (1.374) 38,6 (1.52) 7,92 (.312)
34,87 (1.373) 38,3 (1.51) x 54 (2.13)
35VM 292N 68,4 (2.70) 9,12 (.359) 10,4 (.41) 37,01 (1.457) 35,00 (1.378) 10 (.394)
352*VM 36,75 (1.447) 34,80 (1.370) x 45 (1.77)
35VT*M
35VS 202 84,1 (3.31) 12,7 (.50) 10,4 (.41) 31,75 (1.25) 35,36 (1.39) 7,94 (.313)
352*VS 31,70 (1.24) 34,10 (1.38) x 45 (1.77)
35VT*S 203 84,1 (3.31) 12,7 (.50) 7,9 (.310) 34,90 (1.374) 38,56 (1.518) 7,92 (.312)
35VS 34,87 (1.373) 38,30 (1.508) x 54 (2.125)
352*VS
45V 1 62 (2.44) 12,7 (.500) 14,22 (.560) 31,75 (1.25) 35,36 (1.39) 7,92 (.312)
45**V 31,70 (1.24) 34,10 (1.38) x 28,5 (1.12)
86 87,4 (3.44) 12,7 (.500) 14,22 (.560) 38,07 (1.499) 42,4 (1.67) 9,53 (.375)
38,05 (1.498) 42,1 (1.66) x 50,8 (2.00)
45VS 202 84,1 (3.31) 12,7 (.500) 14,22 (.560) 31,75 (1.25) 35,36 (1.39) 7,94 (.313)
45**VS 31,70 (1.24) 34,10 (1.38) x 63 (2.48)
45VM 292N 92 (3.62) 9,12 (.359) 10,0 (.394) 40,01 (1.575) 43,0 (1.693) 12 (.472)
452*VM 39,99 (1.574) 42,8 (1.685) x 63 (2.48)
45VT*M
45VT*S 203 87,4 (3.44) 9,14 (.360) 7,9 (.310) 38,07 (1.499) 42,4 (1.67) 9,53 (.375)
45VS 38,05 (1.498) 42,1 (1.66) x 57,1 (2.25)
45**VS
Shaft shoulder inside recess in pilot.
B
A
C
1,5 (.06) x 45
D
E
F
EATON Vickers
®
Vane Pumps V Series - Low Noise Vane Pumps 560 November 201132
Optional Shafts
Shaft Spline Data
Pump Code A B C D øE (see below)
20V 151 41,1 (1.62) 9,53 (.375) 11,1 (.437) 3,9 (.156) 27,8 (1.09) A
25V 11 44,5 (1.75) 9,53 (.375) 11,1 (.437) 3,9 (.156) 27,8 (1.09) A
2520V
2525V 174 59,9 (2.36) 9,53 (.375) 17,3 (.68) 3,0 (.12) 29,2 (1.15) B
25VT*S 297 41,1 (1.62) 9,14 (.36) 7,9 (.31) 4,1 (.16) 27,8 (1.09) C
25VS
252*VS
35V 11 58,7 (2.31) 9,53 (.375) 11,1 (.437) 6,35 (.25) 35,1 (1.38) D
352*V
35VT*S 297 55,5 (2.19) 9,14 (.360) 7,9 (.310) 5,5 (.21) 35,1 (1.38) E
35VS
352*VS
45V 11 61,9 (2.44) 12,7 (.500) 14,3 (.565) 9,7 (.38) 39,6 (1.56) D
45**V
45VT*S 297 55,5 (2.19) 9,14 (.360) 7,9 (.310) 9,7 (.38) 39,6 (1.56) E
45VS
45**VS
Spline Data Table
(Involute splines from above chart)
Spline Data Number of
Reference Teeth Pitch Major Diameter Form Diameter Minor Diameter Minor Diameter
A 13 16/32 22,17 (.873) 22,15 (.872) 19,03 (.749) 18,63 (.734) 18,35 (.723) Major dia. fit
B 14 12/24 31,22 (1.23) 31,11 (1.22) 27,48 (1.08) 27,0 (1.063) 26,7 (1.05) Side fit
C 13 16/32 22,2 (.875) 21,7 (.853) 19,03 (.749) 18,4 (.725) Side fit
D 14 12/24 31,7 (1.25) 31,67 (1.247) 27,2 (1.07) 26,99 (1.06) 26,64 (1.05) Major dia. fit
E 14 12/24 31,6 (1.25) 31,1 (1.22) 27,48 (1.08) 26,7 (1.05) Side fit
Splined Shafts
B
A
C
E
D
See spline data table below
EATON Vickers
®
Vane Pumps V Series - Low Noise Vane Pumps 560 November 2011 33
Optional Shafts
Optional ISO 3019/2 Metric Pilot Flange Mounting Options for
“VM” & “VT*M” Pumps
25 and 35 Size Pumps
Model A ØB ØC Pilot diameter
25VM Single Pumps
25VT*M Thru-drive Pumps 14,27 140 175 100,0 (3.937)
25**VM Double Pumps (.562) (5.51) (6.87) 99,95 (3.935)
35VM Single Pumps
35VT*M Thru-drive Pumps 18,34 180 212 125,02 (4.922)
35**VM Double Pumps (.722) (7.09) (8.33) 124.97 (4.920)
45 Size Pumps
45VM Single Pumps
45VT*M Thru-drive Pumps
45**VM Double Pumps
45VT** Thru-drive Pumps Dimension “A
Rear Mounting Type 45VT*S Pumps 45VT*M Pumps
A 291,6 (11.48) 321,8 (12.67)
B 300,7 (11.84) 331,0 (13.03)
BP 317,0 (12.48) 347,2 (13.67)
C 308,4 (12.14) 338,6 (13.33)
160,0 (6.299)
159,9 (6.297)
“A”
73,2
(2.88)
9,12
(.36)
23,8
(.94)
To end of
pump body
A
Stamped
“M”
ØC
ØB
266,7
(10.5)
200,2
(7.88)
22,0 (.866)
thru 2 places
Stamped “M”
Ø
224,0
(8.82)
See Shaft Options
on pages 31 & 32.
Pilot diameter
45VM Adapter Flange
EATON Vickers
®
Vane Pumps V Series - Low Noise Vane Pumps 560 November 201134
Torque Loading for Direct Drives
Single pumps (not thru–drive models) All listed shafts are
satisfactory up to maximum pressures in “Pressure and
speed limits” in operating data for each series.
Double pumps
Where both cartridges are to be on-load together, check
that the sum of their separate torques, taken from the graph
below (right), does not exceed the torque limit in shaft torque
Table 1.
Thru–drive pumps **VT* models Where both the thru-drive
pump and its rear–mounted pump are to be on-load together,
check that the sum of the torques generated will never ex-
ceed the torque limit in shaft torque Table 2. Also check that
the torque required on the rear-mounted pump never exceeds
the thru-drive torque limit in shaft torque Table 2.
Table 2 Thru-Drive Pumps
Shaft Torque Ratings
Max. Input Max. Thru-drive
Pump Shaft Torque Thru-drive Torque
Model No. Nm (Ib-in)* connection Nm (Ib-in)
202 250 (2200) A 131 (1160)
B 250 (2200)
25VT*S 203 400 (3560) A 131 (1160)
25VS B 316 (2800)
242*VS 297 316 (2800) A 131 (1160)
B 316 (2800)
292N 316 (2800) A 131 (1160)
B 316 (2800)
292N 400 (3560) A 131 (1160)
B 316 (2800)
C 400 (3560)
35VT*S 203 600 (5300) A 131 (1160)
35VS B 316 (2800)
352*VS C 437 (3870)
297 790 (7000) A 131 (1160)
B 316 (2800)
C 437 (3870)
292N 904 (8000) A 131 (1160)
B 384 (3400)
C 702 (6210)
45VT*S 203 810(7200) A 131 (1160)
45VS B 384 (3400)
45**VS C 702 (6210)
297 1020 (9000) A 131 (1160)
B 384 (3400)
C 702 (6210)
* Combined torque of Vickers “VT” pump and thru-drive pump.
Table 1
Single & Double Pumps Shaft
Torque Ratings
Maximum input
Pump torque
Model Shaft No. Nm (Ib-in)
1 250 (2200)
11 250 (2200)
25V or 86 400 (3560)
25**V 174 550 (4900)
292N 316 (2800)
1 400 (3560)
35V or 11 580 (5100)
35**V 86 600 (5300)
292N 400 (3560)
1 400 (5300)
45V or 11 820 (7200)
45**V 86 820 (7200)
292N 820 (7200)
Example:
A 3525V38A17 pump oper-
ating at 172 bar (2500 psi)
front section and 138 bar
(2000 psi) rear section will
require over 450 Nm (4000
Ib-in) input torque. There-
fore, all listed shafts are
acceptable except No.1.
EATON Vickers
®
Vane Pumps V Series - Low Noise Vane Pumps 560 November 2011 35
Drives
Recommended Drives
Vickers units are designed for use on direct coaxial drives
using spline connections and/or flexible couplings. If drives
imposing radial and/or axial loads, or key drives are being
considered, consult your Vickers representative for additional
information.
Drive Alignment
Concentricity and angular alignment of shafts are important to
pump life. Misalignment can induce heavy loads on bearings,
causing premature failure. Flexible coupling halves must be
aligned according to the coupling manufacturer’s recommen-
dations.
Universal Joints
When using double universal joint couplings, the shafts must
be parallel and the yokes must be in line. The offset should
be kept as low as possible. Maximum allowable offset will, of
course, vary with application conditions. The pump shaft to
universal joint diametral fit should be close (major diameter
fit) with no appreciable looseness.
Mounting Pad Accessory Drives
A splined shaft is recommended on applications where the
pump shaft is coupled directly into a transmission or gear box.
Spline drives should be lubricated. The possibility of interfer-
ence between the shaft and transmission splines, due to
tolerance stack-up, can exist. To reduce this possibility, side
tooth spline fits should be used. A side tooth fit and short
length of engagement permits more flexibility and less ten-
dency for side loading than does a major diameter fit spline or
long spline engagement.
Mounting Dimensions
Requirements
Dimensional control requirements of the customer’s mount-
ing pad to which the pump or motor is affixed are as follows.
Pilot Diameter
Concentricity of the customer’s female pilot diameter relative
to the effective axis of the female drive must be within .10
mm (.004”) total indicator reading. The clearance between
the male and female pilot diameters must be +.0127 to .0508
mm (+.0005 to +.0020 inch).
Mounting Face
The customer’s mounting face to which the pump or motor is
affixed must be square to the axis of the female drive within
.04 mm per 25 mm (.0015 inch per inch).
Shafts
Dimensions of keyed shaft receivers must be between
+.002554 and +.0254 mm (+.0001 and +.0010) of the maxi-
mum shaft diameter shown on the respective Vickers installa-
tion drawing.
EATON Vickers
®
Vane Pumps V Series - Low Noise Vane Pumps 560 November 201136
Foot Mounting Bracket Option
(Not suitable for thru-drive pumps)
Salts for mounting pump are supplied with bracket.
Part No. A B C D E F G H J
422583 171 178 92 181 93 98 17,4 13 146
(6.75) (7.00) (3.625) (7.125) (3.656) (3.858) (.687) (.50) (5.750)
422584 265 212 109,5 216 129 164 19 16 235
(10.43) (8.37) (4.312) (8.50) (5.06) (6.46) (.750) (.62) (9.250)
Part No. K øL øL1 øN øP rQ R
422583 50,8 101,6 11,1 146 1/2”-13 UNC 51 13
(2.00) (4.00) (.593) (5.750) (2.00)
422584 76,2 127 17,5 180,7 3/8”-11 UNC 64 19
(3.00) (5.00) (.68) (7.125) (2.52)
422583 for use with frame sizes 20, 25 and .2520 pumps. Weighs 2,7 kg (6 Ibs.)
422584 for use with frame sizes 35, 45, 35** and 45** pumps. Weighs 5,9 kg (13 Ibs.)
EATON Vickers
®
Vane Pumps V Series - Low Noise Vane Pumps 560 November 2011 37
Application Data
Moment of Inertia
Moment
Model Nm/sec
2
Ib-in-sec
2
25V 0,000757 (.00670)
35V 0,001395 (.01235)
45V 0,003073 (.02720)
2520V 0,001309 (.01159)
2525V 0,001469 (.01300)
3520V 0,001629 (.01495)
3525V 0,002042 (.01807)
4520V 0,003186 (.02820)
4525V 0,003732 (.03303)
4535V 0,004554 (.04031)
Vane Pump Approximate Weights
Frame size kg (Ibs.)
20V 12.0 (26)
25V 14.8 (33)
25V(T) 19.4 (43)
35V 22.7 (50)
35V(T) 28.7 (63)
45V 34.0 (75)
45V(T) 38.1 (84)
2520V 20.5 (45)
2525V 23,1 (51)
3520V 34.0 (75)
3525V 34.5 (76)
4520V 43.0 (95)
4525V 46.0 (101)
4535V 53.5 (118)
Mounting Options
Mounting attitude of all pumps is unrestricted except for any
limitations in respect to rear-end pumps to be titled to **VT
pumps. Such limitations will be found in the technical litera-
ture for those specific pumps.
Ordering Procedure
State full model designation(s) when ordering pumps. Port
flange kits are available from Vickers and must be ordered as
separate items.
Specify “BP” adapter when coupling PVE12119/21 as second
pump on thru-drives.
Existing “B” thru-drives can be converted to “BP” using the
following kits:
25VT: 941295 Adapter kit
452865 Coupling
35VT/45VT: 941295 Adapter kit only
Note: Adaptor kit and couplings are included with unit when ordered with
“BP” designation in model code.
Service Information
Refer to specific Vickers part drawing or overhaul manual
(below) for service information or consult your Vickers repre-
sentative.
Service Literature:
20V 1-3195-5
25V 1-3196-5
35V 1-3197-5
45V 1-3199-5
2520V 1-3200-5
2525V 1-3212-5
3520V 1-3202-5
3525V 1-3203-5
4520V 1-3204-5
4525V 1-3208-5
4535V 1-3209-5
25VT 1-3154-5
35VT 1-3149-5
45VT 1-3151-5
Overhaul Manuals:
25V 1-3157-5
25VT 1-3157-5
35V 1-3157-5
35VT 1-3157-5
45V 1-3157-5
45VT 1-3157-5
2520V 1-3155-5
3520V 1-3155-5
3525V 1-3155-5
4520V 1-3155-5
4525V 1-3155-5
4535V 1-3155-5
Eaton
Hydraulics Group USA
14615 Lone Oak Road
Eden Prairie, MN 55344
USA
Tel: 952-937-9800
Fax: 952-294-7722
www.eaton.com/hydraulics
Eaton
Hydraulics Group Europe
Route de la Longeraie 7
1110 Morges
Switzerland
Tel: +41 (0) 21 811 4600
Fax: +41 (0) 21 811 4601
Eaton
Hydraulics Group Asia Pacific
Eaton Building
4th Floor, No. 3 Lane
280 Linhong Rd. Changning District
Shanghai 200335
China
Tel: (+86 21) 5200 0099
Fax: (+86 21) 5200 0400
© 2011 Eaton Corporation
All Rights Reserved
Printed in USA
Document No. 560
November 2011