A.7
Response Times, Typical
Time taken from when signal is first
applied at the solenoid until the spool
completes its travel. Based on
DG4V-5-2C at 60 L/min (16 USgpm)
from P to A to B to T and at 160 bar
(2320 psi) with petroleum oil at 36 cSt
(168 SUS) and at 50_C (122_F):
AC energizing 30 ms. . . . . . . . . . . . . . . . .
AC de-energizing 40 ms. . . . . . . . . . . . . .
DC energizing 120 msY. . . . . . . . . . . . . .
DC de-energizing 45 msY:. . . . . . . . . .
: In pure switched conditions, devoid of the
efffects of any suppression diodes and
full-wave rectifiers.
Y DG4V-5-2CJ valves. Longer response
times can be obtained by fitting an orifice
plug in a special pilot port, standard in all
bodies. An orifice kit 459065, containing a
selection of plugs of differing orifice size,
can be ordered separately. Ask your
Vickers representative for details.
Hydraulic Fluids
Water glycols can be used with
F13-prefix DC-voltage models or with
non-prefix AC-voltage models.
Non-prefix DC-voltage models and all
AC-voltage models can be used with
anti-wear hydraulic oils, water-in-oil
emulsions, phosphate esters (not alkyl
based).
The extreme operating viscosity range is
from 500 to 13 cSt (2300 to 70 SUS) but
the recommended running range is 54 to
13 cSt (245 to 70 SUS).
For further information about fluids see
catalog 920.
Temperature Limits
Minimum ambient –20_C (–4_F). . . . . . .
Maximum ambient:
AC 50 Hz valves 50_C (122_F). . . . . .
AC 60 Hz valves 40_C (104_F). . . . . .
DC valves 70_C (158_F). . . . . . . . . . . .
Fluid temperatures
Petroleum
oil
Water-
containing
Min.
Max.*
–20_C
(–4_F)
+70_C
(+158_F)
+10_C
(+50_F)
+54_C
(+130_F)
* To obtain optimum service life from both
fluid and hydraulic system, 65_C (150_F)
normally is the maximum temperature
except for water-containing fluids.
For synthetic fluids consult manufacturer
or Vickers where limits are outside those
for petroleum oil.
Whatever the actual temperature range,
ensure that viscosities stay within the
limits specified in the “Hydraulic Fluids”
section.
Solenoid Surface Temperatures
Typical maximums at 20_C (68_F)
ambient:
AC 50 Hz solenoids 80_C (176_F). . . . .
AC 60 Hz solenoids 92_C (197_F). . . . .
DC solenoids 78_C (172_F). . . . . . . . . .
Contamination Control Requirements
Recommendations on contamination
control methods and the selection of
products to control fluid condition are
included in Vickers publication 9132 or
561, “Vickers Guide to Systemic
Contamination Control”. The book also
includes information on the Vickers
concept of “ProActive Maintenance”.
The following recommendations are
based on ISO cleanliness levels at
2 mm, 5 mm and 15 mm. For products in
this catalog the recommended levels
are:
Up to 210 bar (3050 psi) 20/18/15. . . . .
Above 210 bar (3050 psi) 19/17/14. . . .
Mass, Approx. kg (lb)
Single solenoid models,
AC coils 4,0 (8.8). . . . . . . . . . . . . . . . . . . .
Single solenoid models,
DC coils 4,8 (10.6). . . . . . . . . . . . . . . . . . .
Double solenoid models,
AC coils 4,5 (9.9). . . . . . . . . . . . . . . . . . . .
Double solenoid models,
DC coils 6,3 (13.9). . . . . . . . . . . . . . . . . . .