A.1
Model DG4V-5, 20 Series
Typical Construction of a
Spring-Centered DC Valve with
Variable Speed Pilot Control passage
General Description
Max. pressure 315 bar (4500 psi). . . . . .
Max. flow rates Up to 120 L/min. . . . . . .
(32 USgpm),
dependent on spool
Mounting surface ISO 4401 size 05. . . .
NFPA D02
DIN 24340 (NG10)
A range of four-port solenoid operated
directional control valves with four-land
spool design to facilitate provision of
smooth, variable valve response
speeds.
The range includes:
F AC and DC wet-armature solenoid
options with ISO 4400 (DIN 43650)
electrical connections and manual
overrides.
F Variable speed changeover potential
in all DC models; see “Response
Times” section
F Many spool types; in spring-offset,
spring-centered and detented
arrangements.
5069.00/EN/0497/A
Wet Armature Solenoid Operated Directional
Control Valves
Vickers
®
Directional Controls
Functional Symbols
Sol. B Sol. A
A B
P T
Sol. B Sol. A
A B
P T
Sol. B
A B
P T
Sol. A
A B
P T
Double Solenoid Valves,
Tw
o-Position, Detented
Single S
olenoid Valves,
Solenoid at Port A End
S
ingle S
olenoid Valves,
Solenoid at Port B End
Double
Solenoid Valves,
Spring Centered
DG4V-5-*N valves
DG4V-5-*C valves
DG4V-5-*A valves
DG4V-5-*AL valves
DG4V-5-*BL valvesDG4V-5-*B valves
2
6
2
2
222
6 6 6
3
1
0
3
3
0
0
0
0
1
1
22
22
23
23
7
7
7
8 8
8
11
31
33
34
52
56
521
561
521
561
56
52
33
34
33
34
31
31
11
11
Transient condition only.
Both ports T
A
and T
B
are available.
A.2
Model Code
Prefix, fluid compatibility
Blank = AC or DC-voltage models for
petroleum oils, water-in-oil
(invert) emulsions or
phosphate esters.
AC-voltage models for water
glycols.
F13 = DC-voltage models for water
glycols.
Spool type
See Functional Symbols section
Spool spring arrangement
A = Spring-offset, end-to-end
AL = As A but left-hand build
B = Spring offset, end-to-center
BL = As B but left-hand build
C = Spring centered
N = Two-position, detented
See also Functional Symbols section
Spool design
J = All DC valves except 0A
spool/spring arrangements.
AC valves with 8B(L) and 8C
spool/spring arrangements.
Omit for 0A DC-valves and all AC
valves except 8B(L) and 8C
spool/spring arrangements
Manual override option
P = Standard overrides in both ends
of single-solenoid valves
H = Water-resistant override(s) in
solenoid end(s)B
H2 = Water-resistant overrides in both
ends of single-solenoid valves
Z = No overrides at either end
Omit for standard plain override(s) in
solenoid end(s) onlyB
B No override in non-solenoid end of
single-solenoid valves.
1 2 3
9
1
2
3
4
4
Solenoid energization identity
V = Solenoid A is at port A end
and/or solenoid B is at port B
end, independent of spool type
Omit for US ANSI B93.9 standard
requiring solenoid A to connect P to A
when energized and/or solenoid B to
connect P to B
Spool position indicator switch
S6 - LVDT type DC switch with Pg7
connector plug
Electrical connection(s)
U = ISO 4400 (DIN 43650)
mounting(s) without plug(s)
Coil rating
A = 110V AC 50
C = 220V AC 50
ED = 240V AC 50
EK = 115V AC 60
EH = 230V AC 60
G = 12V DC
H = 24V DC
HL = 24V DC (32W)
OJ = 48V DC
P = 110V DC
Design number, 20 series
Subject to change. Installation
dimensions unaltered for design
numbers 20 to 29 inclusive
Spool speed control
J06 = 0,6 mm orifice
J08 = 0,8 mm orifice
J10 = 1,0 mm orifice
J12 = 1,2 mm orifice
J99 = no orifice. Must be specified
where future fitting of orifice is required,
see page A.11, Spool Speed Control
Orifice
5
6
5 6 7 8
7
8
9
11
10
8
(F13-) DG4V-5-*** *(L) (J) (-**)- (V) M- (S6)- U - ** 6- 20- J**
10
11
A.3
For Mounting Subplates and Fixing
Bolt Kits
See catalogs 2425 and 2314.
For Electrical Plug(s)
See end of Installation Dimensions
section.
Operating Data
Max. Pressures
Ports P, A and B 315 bar (4500 psi). . . .
Ports T
A
and T
B
120 bar (1750 psi). . . .
for AC sol.
160 bar (2325 psi)
for DC sol.
Control Data
For coil ratings see in Model Code
section.
Power Consumption
AC Solenoids
AC
50 Hz
AC
60 Hz
Inrush, max. YVA
Steady-state BVA
Holding VA
700
375
105
750
440
130
All above values are RMS
Y Armature fully retracted, 1st half-cycle.
B At start of normal working stroke of valve
spool. Previously called “Inrush”.
DC Solenoids
At rated voltage and wire temperature of
20_C (68_F):
Type HL 32W. . . . . . . . . . . . . . . . . . . . . .
Others 38-42W. . . . . . . . . . . . . . . . . . . . . .
Performance Data
0
0
0
2
4
6
8
10
12
14
16
Pressure drop
psi bar
Flow rate
20 40 60 80 100 120 L/min
100
200
150
50
205 10 15 25 30 US gpm
1
2
3
4
5
6
7
8
9
10
0
0
0
Pressure drop
psi bar
Flow rate
20 40 60 80 100 120 L/min
205 10 15 25 30 US gpm
25
50
100
200
150
75
125
175
225
500
1000
1500
2000
2500
3000
11
12
A.4
Pressure Drops Typical with petroleum oil at 36 cSt (170 SUS) and a specific gravity of 0,87
Spool/spring code Spool positions
covered
P to A P to B A to T B to T P to T A to B or
B to A
0A(L) Both 2 2 4 5
0B(L) & 0C De-energized
Energized
1
1
6
7
3Y
1B(L) & 1C De-energized
Energized
1
2
6
4
6B
2A(L) Both 3 3 5 6
2B(L) & 2C All 2 2 4 5
2N Both 3 3 5 6
3B(L) & 3C De-energized
Energized
2
3
5
6
5
6B(L) & 6C De-energized
Energized
3
3
5F
6
6B
7
6N Both 4 4 4 5
7B(L) & 7C De-energized
Energized
3F
2
3B
2
5
6
5g
8B(L) & 8C All 2 2 7 8 8
11B(L) & 11C De-energized
Energized
2
1
4
7
6F
22A(L) Both 3 3
23A(L) Both 3 3 5 6
31B(L) & 31C De-energized
Energized
3
2
4
6
7
33B(L) & 33C De-energized
Energized
2
2
12F
5
12B
6
34B(L) & 34C De-energized
Energized
2
2
11F
5
11B
6
52BL & 52C All 7F 8 4 9g
56BL & 56C De-energized
Energized
7F
8
8F
6
10B
9g
521B & 521C All 8 7B 5 9g
561B & 561C De-energized
Energized
8
7B
10F
8B
7
9g
Y A and B blocked B A blocked F B blocked g P blocked
A.5
Operating Data
Spool Position Indicator Models
Spool/spring arrangement types 0A (L), 2A(L), 22A(L)
DC model type “S6”
This product has been designed and tested to meet specific standards outlined in the European Electromagnetic Compatibility
Directive (EMC) 89/336/EEC, amended by 91/263/EEC, 92/31/EEC and 93/68/EEC, article 5. For instructions on installation
requirements to achieve effective protection levels see this leaflet and the Installation Wiring Practices for Vickers Electronic
Products leaflet 2468. Wiring practices relevant to this Directive are indicated by
Electromagnetic Compatibility (EMC) .
Input:
Supply voltage 10 to 35V DC inclusive of a maximum 4V pk-to-pk ripple
Current, switch open 5 mA
Current, switch closed 255 mA
Output:
Voltage 1V below input at maximum load
Maximum continuous current 250 mA
Maximum load impedance 136 at maximum input volts
Maximum switching frequency 10 Hz
Plug connections:
Pin 1 (output 1) Normally open (ie. not connected to pin 3)
Pin 2 Supply +ve
Pin 3 0V
Pin 4 (output 2) Normally closed (ie. connected to pin 3)
Switching point Within the spool spring offset condition D
Connector Pg7 plug (supplied with valve)
Protection Overload and short-circuit protected; self re-setting.
IEC 144 class IP65 with connector correctly fitted.
D Factory setting ensures this condition under all combinations of manufacturing tolerance and of temperature drift (see Temperature Limits) .
Customers protective ground connection
Solenoid
LVDT
Warning
All power must be switched off before
connecting or disconnecting any plugs.
Wiring Connections
Electrical
Panel
WARNING: Electromagnetic Compatibility (EMC)
It is necessary to ensure that the unit is wired up in accordance with the connection arrangements shown above. For
effective protection the users electrical cabinet, the valve subplate or manifold and the cable screens should be
connected to efficient ground points.
In all cases both valve and cable should be kept as far away as possible from any sources of electromagnetic
radiation such as cables carrying heavy current, relays and certain kinds of portable radio transmitters, etc. Difficult
environments could mean that extra screening may be necessary to avoid the interference.
AC Solenoid Valves
DC Solenoid Valves
0
0
0
psi bar
Flow rate
20 40 60 80 100 120 L/min
205 10 15 25 30 US gpm
100
200
1000
2000
3000
Pressure
300
350
4000
5000
3154500
1
2
3
4
5
6
7
5
&
7
0
0
0
psi bar
Flow rate
20 40 60 80 100 120 L/min
205 10 15 25 30 US gpm
100
200
1000
2000
3000
Pressure
300
350
4000
5000
3154500
1
2
3
4
6
7
5
A.6
Max. Flow Rates
Based on warm solenoid(s) operating at
10% below rated voltage.
Flow limits applicable to following
usages:
1. All valves except those with types 22,
52, 56, 521 and 561 spools having
simultaneous equal flow rates from P
to A or B and from B or A to T.
2. Valves with type 22 spools having
flow from P to A or B, the other being
blocked. T is drained at all times.
3. Valves with types 52, 56, 521 and
561 spools having one service port
connected to the full bore end of a
2:1 area ratio double-acting cylinder
and the other service port to the
annulus end.
4. Valves with type 23 spools having
single flow from A or B to T, P and the
other service port being blocked.
Consult Vickers with application details if
any of the following are required:
a) Single flow path, i.e. P to A, P to B,
A to T or B to T.
b) Substantially different simultaneous
flow rates between P to A or B and
B or A to T.
c) Spools as in 3 above are to be used
with cylinder ratios greater than about
3:1 at low flow rates or 2:1 at high
flow rates.
Spool/spring code
AC valve graph curve DC valve graph curve
0A(L)
0B(L) & 0C
1B(L) & 1C
2A(L)
2B(L), 2C & 2N
3B(L), 3C, 6B(L) & 6C
6N
7B(L) & 7C
8B(L) & 8C
11B(L), 11C & 22A(L)
23A(L)
31B(L) & 31C
33B(L), 33C, 34B(L) & 34C
52B(L), 52C, 56BL, 56C,
521B, 521C, 561B & 561C
3
2
6
3
1
4
3
1
7
6
5
4
3
4
2
4
7
2
1
6
3
1
5
7
6
6
6
6
A.7
Response Times, Typical
Time taken from when signal is first
applied at the solenoid until the spool
completes its travel. Based on
DG4V-5-2C at 60 L/min (16 USgpm)
from P to A to B to T and at 160 bar
(2320 psi) with petroleum oil at 36 cSt
(168 SUS) and at 50_C (122_F):
AC energizing 30 ms. . . . . . . . . . . . . . . . .
AC de-energizing 40 ms. . . . . . . . . . . . . .
DC energizing 120 msY. . . . . . . . . . . . . .
DC de-energizing 45 msY:. . . . . . . . . .
: In pure switched conditions, devoid of the
efffects of any suppression diodes and
full-wave rectifiers.
Y DG4V-5-2CJ valves. Longer response
times can be obtained by fitting an orifice
plug in a special pilot port, standard in all
bodies. An orifice kit 459065, containing a
selection of plugs of differing orifice size,
can be ordered separately. Ask your
Vickers representative for details.
Hydraulic Fluids
Water glycols can be used with
F13-prefix DC-voltage models or with
non-prefix AC-voltage models.
Non-prefix DC-voltage models and all
AC-voltage models can be used with
anti-wear hydraulic oils, water-in-oil
emulsions, phosphate esters (not alkyl
based).
The extreme operating viscosity range is
from 500 to 13 cSt (2300 to 70 SUS) but
the recommended running range is 54 to
13 cSt (245 to 70 SUS).
For further information about fluids see
catalog 920.
Temperature Limits
Minimum ambient 20_C (4_F). . . . . . .
Maximum ambient:
AC 50 Hz valves 50_C (122_F). . . . . .
AC 60 Hz valves 40_C (104_F). . . . . .
DC valves 70_C (158_F). . . . . . . . . . . .
Fluid temperatures
Petroleum
oil
Water-
containing
Min.
Max.*
20_C
(4_F)
+70_C
(+158_F)
+10_C
(+50_F)
+54_C
(+130_F)
* To obtain optimum service life from both
fluid and hydraulic system, 65_C (150_F)
normally is the maximum temperature
except for water-containing fluids.
For synthetic fluids consult manufacturer
or Vickers where limits are outside those
for petroleum oil.
Whatever the actual temperature range,
ensure that viscosities stay within the
limits specified in the Hydraulic Fluids
section.
Solenoid Surface Temperatures
Typical maximums at 20_C (68_F)
ambient:
AC 50 Hz solenoids 80_C (176_F). . . . .
AC 60 Hz solenoids 92_C (197_F). . . . .
DC solenoids 78_C (172_F). . . . . . . . . .
Contamination Control Requirements
Recommendations on contamination
control methods and the selection of
products to control fluid condition are
included in Vickers publication 9132 or
561, Vickers Guide to Systemic
Contamination Control. The book also
includes information on the Vickers
concept of ProActive Maintenance.
The following recommendations are
based on ISO cleanliness levels at
2 mm, 5 mm and 15 mm. For products in
this catalog the recommended levels
are:
Up to 210 bar (3050 psi) 20/18/15. . . . .
Above 210 bar (3050 psi) 19/17/14. . . .
Mass, Approx. kg (lb)
Single solenoid models,
AC coils 4,0 (8.8). . . . . . . . . . . . . . . . . . . .
Single solenoid models,
DC coils 4,8 (10.6). . . . . . . . . . . . . . . . . . .
Double solenoid models,
AC coils 4,5 (9.9). . . . . . . . . . . . . . . . . . . .
Double solenoid models,
DC coils 6,3 (13.9). . . . . . . . . . . . . . . . . . .
A.8
AC Solenoid Models
Installation Dimensions in mm (inches)
Y May vary according to plug source.
z The cable entry can be repositioned at 90_
intervals from the position shown.
This is done by reassembling the contact
holder into the appropriate position inside
the plug housing.
3rd angle
projection
13 (0.5) for plug removal
115 (4.53) Y
Fixing
bolt
75 (2.95)
for coil
removal
80
(3.15)
36 (1.4)
30
(1.18)
75 (2.95)
for coil
removal
C
D
E
F
G
AB
67 (2.6) 67 (2.6)
See Electrical plugs table below z
CA & B
Ports
C
71 (2.8)
AC models
74,0
(2.91)
Model Solenoid at: C D E F G
DG4V-5-*A(L)/B(L)(-Z)-(V)M
Port A end
Port B end
123 (4.84)
123 (4.84)
182 (7.17)
182 (7.17)
DG4V-5-*A(L)/B(L)-H2-(V)M
Port A end
Port B end
138 (5.43)
138 (5.43)
223 (8.78)
223 (8.78)
DG4V-5-*A(L)/B(L)-P-(V)M
Port A end
Port B end
123 (4.84)
123 (4.84)
195 (7.68)
195 (7.68)
DG4V-5-*C/N(-Z)-(V)M Both ends 123 (4.84) 123 (4.84) 246 (9.68)
DG4V-5-*C/N-H-(V)M Both ends 138 (5.43) 138 (5.43) 276 (10.87)
A.9
DC Solenoid Models
Y May vary according to plug source.
z The cable entry can be repositioned at 90_
intervals from the position shown.
This is done by reassembling the contact
holder into the appropriate position inside
the plug housing.
110 (4.33)
for coil
removal
C
D
E
F
G
AB
30
(1.18)
36 (1.4)
78
(3.1)
113 (4.45) Y
13 (0.5) for plug removal
Fixing
bolt
CA & B
Ports
C
70 (2.76)
DC models
101 (4.0)
See Electrical plugs table below z
101 (4.0)
110 (4.33)
for coil
removal
3rd angle
projection
Model
Solenoid at: C D E F G
DG4V-5-*A(L)/B(L)-(-Z)-(V)M
Port A end
Port B end
156 (6.14)
156 (6.14)
215 (8.46)
215 (8.46)
DG4V-5-*A(L)/B(L)-H2-(V)M
Port A end
Port B end
185 (7.28)
185 (7.28)
270 (10.63)
270 (10.63)
DG4V-5-*A(L)/B(L)-P-(V)M
Port A end
Port B end
156 (6.14)
156 (6.14)
228 (8.98)
228 (8.98)
DG4V-5-*C/N(-Z)-(V)M Both ends 156 (6.14) 156 (6.14) 312 (12.28)
DG4V-5-*C/N-H-(V)M Both ends 185 (7.28) 185 (7.28) 370 (14.57)
Location of switch
for RH build modelsY
Plug (part no. 458939)
supplied with valve
Cable gland PG7:
6,0 (0.24) dia.
Pin number 2, supply +ve
Pin number 3, 0V
Pin number 1,
normally
open
Pin number 4,
normally
closed
AB
DC Sol.
AC Sol.
For manual override type H: 337,0 (13.270)
For other models: 308,0 (12.13)
For manual override type H:
138,0 (5.43)
For other models: 123,0 (4.84)
For manual override type H: 289,0 (11.4)
For other models: 274,0 (10.8)
Location of solenoid
for RH build models
Y For LH models (L in model code location )
solenoid and switch locations are reversed
3rd angle
projection
Wiring: See warning note on page A.5
3
Spool Position Indicator Switch Models
LVDT
A.10
A.11
Model (see also in
Model Codes)
5
Spool types Solenoid identity
Port A Port B
end end
DG4V-5-*A(J)/B(J)(-**)-M All except 8 B
DG4V 5
*
A(J)/B(J)(
**
)VM
All except 8 A
DG4V-5-*A(J)/B(J)(-**)-VM
8 only
B
DG4V-5-*AL(J)/BL(J)(-**)-M All except 8 A
DG4V-5-
*
AL(J)/BL(J)(-
**
)-VM
All except 8 B
DG4V
-5-
*AL(J)/BL(J)(
-
**)
-
VM
8 only A
DG4V-5-*C(J)/N(J)(-**)-M All except 8 B A
DG4V-5-*C(J)/N(J)(-**)-VM All spools A B
Electrical plug(s) (without indicator light) to
DIN 43650.
Must be ordered separately by part number(s).
Part No.
Color Solenoid
/LVDT
identity
Cable gland
710775 Black B Pg11 Ø6-10 mm
710776 Gray A Pg11 Ø6-10 mm
458939 Gray LVDT Pg7 Ø3,5-6 mm
Spool Speed Control Orifice
For fine tuning of valve spool speed.
Only applicable to valves already fitted
with an orifice or blank plug, see model
code, page A.3.
Warning - Changing procedure
Before breaking a circuit
connection make certain that power is
off and system pressure has been
released. Lower all vertical cylinders,
discharge accumulators and block any
load whose movement could generate
pressure. Plug all removed units and
cap all lines to prevent entry of dirt into
the system.
Orifice Kit
Orifice kits must be ordered separately,
part number 02-350116.
Kit comprises 1 off each of the following:
0,6 mm dia
0,8 mm dia
1,0 mm dia
1,2 mm dia
Blank