HP05H valves provide high pressure
capability greater than D05H valves.
The valve’s low pressure drop is
enhanced with the use of the Dynex
standard subplate, which takes
advantage of the valve’s special
double tank port design.
Mounting
Although similar to standard NFPA
D05 (CETOP 5) valves in size, HP05H
valves require a special high pressure
mounting pattern. This pattern
incorporates auxiliary “X” and “Y”
ports for external pilot and drain.
Refer to page 3.
Actuator Options
6600 Series: Solenoid Operated.
6800 Series: Hydraulic Piloted.
6900 Series: Air Piloted.
Rated Flow
Nominal: 30 U.S. gpm (114 L/min).
Maximum: 40 U.S. gpm (151 L/min).
Rated Pressure
8500 psi (586 bar).
Tank Port Pressure (Maximum)
3000 psi (210 bar).
Response Time (Full Stroke)
Spring Centered models:
Solenoid Energized, 40-70 ms.
Spring Returned, 40-45 ms.
Spring Offset models:
Solenoid Energized, 50-55 ms.
Spring Returned, 85 ms.
Standard Seals
All valves use Fluorocarbon (Viton®,
Fluorel®, or equivalent) o-rings,
providing greater fluid compatibility
and increased temperature range
performance. EPR seals can be
provided as an option.
ENGINEERING
SPECIFICATIONS
High Pressure, Subplate Mounted
Directional Control Valves
HP05H SERIES
30 gpm (114 L/min) Nominal
40 gpm (151 L/min) Maximum
8500 psi (586 bar)
Table of Contents
All Models Internal Operators Page 2
All Models Spool Descriptions Page 2
All Models Performance Page 3
All Models Mounting Page 3
6600 Series Solenoid Operated Page 4
6800 Series Hydraulic Piloted Page 7
6900 Series Air Piloted Page 8
All Models Model Code Page 9
Fluid Recommendations
50 to 1500 SUS (7 to 323 cSt) viscosity;
-20° to 200° F (-29° to 93° C)
temperature range.
Recommended Filtration
Use filtration to provide fluid which
meets these ISO Code 4406 cleanliness
values: 19/17/14.
Internal Operator Descriptions
Internal
Operator
Code
Actuator,
Operation
Operator Functions
Spool Type Non-Actuated Actuated Function Symbol
1
Single Actuator,
Two Position
25 or 26 P
B P
A
2
Single Actuator,
Two Position
25 or 26 P
A P
B
3
Double
Actuator,
Two Position
5 or 6
Detented in
Actuated
Positions
P
A
or
P
B
4
Single Actuator,
Two Position
5, 6, or 8
Spring
Centered
P
A
5, 6, or 8
Reverse
Spring
Centered
P
B
5
Double Actuator,
Three Position
5, 6, or 8
Spring
Centered
P
A
or
P
B
INTERNAL OPERATORS
The table shows available internal
operators and the most common spools.
Refer to Typical Model Code on page
9 to specify valve model. Contact the
Dynex Sales department for availability
of spool options not shown.
The function symbols in the table show
solenoid or lever actuated models as
reference. Air and hydraulic actuators
are also available.
Flow pattern in the center position
or during crossover is determined
by the selected spool. Refer to Spool
Descriptions below.
Flow Patterns
Actuator A opens flow path (P
A).
Actuator “B” opens flow path (P
B).
Spring Centered and Spring Offset
models are spring positioned
unless actuated.
Detented Models (Solenoid Operated)
Code 3 operators (two position
detented) hold the spool in the last
actuated position. These valves can
be actuated momentarily (minimum
electrical signal duration, 50 ms) to
shift and hold the spool in that position.
Reverse “R” Option
(Internal Operator Code 4 Only)
Flow pattern can be altered with “R”
(Reverse Assembly) option. Refer to
Internal Operator Descriptions table
for flow pattern details.
B
A
B
A
P
T
A
A
B
P
T
B
P
T
A
B
P
T
A
B
B A
A
B
P
T
A
A
B
P
T
B
A & B represent the actuator(s), which can be Air, Hydraulic or Solenoid.
Spool Descriptions
Spool Type Spool Symbol Crossover Function Description of Spool Function
5, (25) Closed center spool. All ports blocked in center position.
6, (26)
Open center spool. All ports connected in center position. Allows fluid motors or
cylinders to move when de-energized. Minimum shock during crossover.
8 Pressure port blocked in center position. Both A and B ports connected to tank.
A
B
P
T
A
B
P
T
A
B
P
T
A
B
P
T
A
B
P
T
A
B
P
T
A
B
B
B
A
A
A & B represent the actuator(s), which can be Air, Hydraulic, or Solenoid.
A
B
B
Represents the actuators.
Represents the work ports of the valve.
2
Flow Curve Reference
Flow
Path
Spool Type
5 6 8 9 25 26
P
A C F D F D D
P
B A B
A
T G I
B
T H K K H I J
P
T E
Pressure Drop (
P)
600
500
400
300
200
100
0
40
35
30
25
20
15
10
5
0
A
B
C
D
E
F
G
H
I
J
K
gpm
VALVE EFFICIENCY
Efficiencies for all models are shown by
the typical performance curves. The table
identifies the appropriate pressure drop
curve for each spool and flow path.
See Typical Pressure Drop
example below.
2.562
(65,07)
4X .3125-18 UNC-2B
.38 (9,7) DP MIN
P
BA
T
Y
T
X
.656
(16,66)
.437
(11,10)
.918
(23,32)
(45,52)
1.792
(49,78)
1.960
(66,7 MIN)
2.63 MIN
2X
.188
(4,78)
(8,4)
.33
EXTERNAL PILOT
(26,97)
1.062
5X
.438
(11,13)
(37,31)
1.469
(53,98)
2.125
(92,1 MIN)
3.63 MIN
(4,24)
.167
.0004 (0,010/102)
.324
(8,23)
(34,42)
1.355
32
(0,80)
EXTERNAL DRAIN
Recommended Minimum Mounting Surface, special HP05H pattern with
auxiliary “X” and “Y” ports and two tank ports “T” into common tank passageway.
3
VALVE MOUNTING
HP05H valves have a second T” port into
a common tank passageway, for lower
pressure drop. HP05H valves require a
special high pressure mounting pattern
with auxiliary “X” and “Y ports for
external pilot and drain.
Port O-rings are included with valves.
Mounting bolts must be ordered
separately: .3125-18 UNC-2B Threaded
x 1.00 inch (25,4 mm), Grade 8 or better,
four required. Recommended mounting
torque is 25 lb•ft (34 N•m).
X = External Pilot
Y = External Drain
In the case of a 68xx model, the X and Y
ports function as both External Pilot and
Drain.
Typical Pressure Drop (
P Example)
From Flow Curve Reference table:
Spool Type “5” with the Flow Path
for P
A function = (C curve)
Spool Type “5” with the Flow Path
for B
T function = (H curve)
From Pressure Drop (ΔP) Curves:
At 40 gpm: (C curve) =
approx. 550 psi (38 bar) (P
A)
At 40 gpm: (H curve) =
approx. 320 psi (22 bar) (B
T)
To determine total
(for example: P
A + B
T):
Loop Pressure Drop =
550 psi + 320 psi = 870 psi (60 bar)
1.55
(39,3)
2-PIN DEUTSCH
CONNECTOR
1.34
(34,1)
1.80
(45,7)
1.33
(33,7)
DC DIN CONNECTOR
COIL
AC DEUTSCH CONNECTOR
COIL
DC DEUTSCH CONNECTOR
COIL
1.67
(42,5)
1.69
(42,9)
1.55
(39,3)
1.05
(26,8)
2.79
(70,8)
1.65
(42)
ELECTRICAL CONNECTOR
TO FIT EN175301-803
(DIN 43650 FORM A) CONNECTOR
AC DIN CONNECTOR
COIL
Solenoid Electrical Data
Solenoid Type Volts
Coil Resistance (Ohms)
at 77º F (25º C) Power (Watts)
AC
24AC
19.4 - 21.4 23
115AC
444 - 492 23
230AC
1823 - 1941 23
DC
12DC 4.56 - 5.04 30
24DC 18.24 - 20.16 30
Explosion Proof
115AC
559.0 18.6
24DC 30.3 19
Information shown is for 60Hz models only. At other frequencies the coil characteristics must be revised.
SOLENOID OPTIONS
These models use a D03 valve as a pilot.
Models are available with AC or
DC solenoids.
Electrical Connections
Plug-In-Terminal Solenoids fit Deutsch
DT04-2P Connector or EN175301-803
(DIN 43650 Form A) Connector.
Standard Solenoids
Solenoids are easily removed without
manual wiring or opening the hydraulic
system for replacement. Coils can be
rotated 360
º
for flexible installation.
CSA/UL Recognized
PART NUMBERS
Part Number Description
Subplates:
PSO34-HP05H-
SAE12
Side Ports,
No. 12 SAE
PSO34-HP05H-
BSP12
Side Ports,
G 3/4 (BSPP)
PSO34-HP05H-.75MP
Side Ports,
Medium Pressure
Coned and Threaded
.75 NPSM
Mounting Bolts:
P34-BK-16
Four .3125-18 UNC
Threaded x 1.00 inch
(25,4 mm)
Port fits British Standard Pipe Parallel fitting.
High pressure port fits Autoclave Medium
Pressure, Butech M/P or equivalent fitting.
T
P
P
T
EXTERNAL DRAIN (STANDARD) PLUGGED
INTERNAL DRAIN (ID OPTION) PLUG REMOVED
Section X-X
SUBPLATE AND BOLT KITS
Subplates are available for mounting
HP05H pattern valves, with a choice
of SAE or British Standard Pipe Parallel
(BSPP) ports, or ports which fit
Autoclave or Butech fittings.
Mounting bolts are supplied with kit.
When ordering together, valves are not
mounted on subplates.
Pilot and Drain Options
Important: All HP05H valve
configurations require "XP" External Pilot
for operation.
The Section X-X drawing on the right
shows the location of the plug for
external drain. Omitted for internal drain.
Note: All 68xx models require the
drain plug to be installed.
4
2.97
(75,4)
5.01
(127,3)
5.46
(138,6)
5.31
(135)
1.34
(34)
4.35
(110,5)
7.19
(182,5)
1.44
(36,6)
4X .250-20 UNC-2B X 1.00 LG. SHCS
TORQUE TO 12 LB-FT (16 Nm)
2.85
(72,3)
1.73
(43,9)
P
.49
(12,5)
1.69
(42,8)
7.89
(200,3)
.62
(15,7)
GRIP
.40
(10)
2.75
(69,9)
COIL RETAINING NUT
TORQUE: HAND TIGHT
1.75
(44,4)
EXTERNAL EARTH
GROUND CONNECTION
2.5 MM (.098 IN.) HEX
3.01
(76,5)
2.33
(59,1)
PUSH TO ACTIVATE
MANUAL OVERRIDE
COVER CAN BE ORIENTED
ANY DIRECTION
.500-14 NPT ELECTRICAL ENTRY
TORQUE TO 15 LB-IN (1,7 Nm)
SOLENOID TUBE
TORQUE TO 12 LB-FT (16 Nm)
ON TUBE FLATS
(UNDERNEATH COIL)
EXPLOSION PROOF
SOLENOID OPTIONS
“EP” solenoids with special enclosures
are approved by UL and CSA for use in
hazardous locations.
See table for Solenoid Ratings.
Weight (Mass):
661, 662, 664 Models,
15.2 lb (6,9 kg)
.
663 Models,
16.1 lb (7,3 kg)
.
665 Models:
16.6 lb (7,5 kg)
.
6600 Series, Single “EP” Solenoid Models
5
Explosion Proof Solenoid Ratings
Location Governing Standard Dust & Gas Ratings
United States NEC 500
Class I (Division 1) Group C & D
Class II (Division 1) Group E, F, & G
United States NEC 505 & 506
Class I (Zone 1) AEx db IIC T4 Gb
Class I (Zone 21) AEx tb IIIC T135 Db
Canada CEC/CSA Ex db IIC T4 Gb (Zone 1)
Europe ATEX CЄ2813 II 2GD
International
(Excluding Above)
IECEx
Ex db IIC T4 Gb
Ex tb IIIC T135 Db
2.97
(75,4)
5.01
(127,3)
5.46
(138,6)
5.31
(135)
1.34
(34)
4.35
(110,5)
8.38
(212,9)
5.99
(152,1)
663*
665*
1.44
(36,6)
4X .250-20 UNC-2B X 1.00
LG. SHCS TORQUE
TO 12 LB-FT (16 Nm)
2.85
(72,3)
1.73
(43,9)
P
1.63
(41,5)
1.69
(42,8)
11.74
(298,2)
.62
(15,7)
GRIP
.40
(10)
2.75
(69,9)
COIL RETAINING NUT
TORQUE: HAND TIGHT
1.75
(44,4)
EXTERNAL EARTH
GROUND CONNECTION
2.5 MM (.098 IN.) HEX
3.01
(76,5)
2.33
(59,1)
PUSH TO ACTIVATE
MANUAL OVERRIDE
COVER CAN BE
ORIENTED ANY
DIRECTION
.500-14 NPT ELECTRICAL ENTRY
TORQUE TO 15 LB-IN (1,7 Nm)
SOLENOID TUBE
TORQUE TO 12 LB-FT (16 Nm)
ON TUBE FLATS
(UNDERNEATH COIL)
6600 Series, Double “EP” Solenoid Models
Installation Instructions:
1. Temperature of the fluid flowing through the valve and the solenoid must not exceed ambient temperature
specified on the nameplate (-65
º
F to 140
º
F (-54
º
C to 60
º
C)).
2. Fasteners securing the terminal box cover shall be M4X0.7-6G X 15mm per ISO-4762 and torqued to
15 LB-IN. Material: A2 - 70 or A4 - 70 of ISO-3506-1
3. Solenoid shall be mounted to a valve body/manifold/frame as heat sink ≥ 225 cm² surface area and
mass of 1.7 kg of steel.
4. Note coil is polarity insensitive.
5. Solenoid tube to be torqued to 12 LB-FT min.
6600 SERIES SOLENOID
OPERATED MODELS
Models use a HP03 valve as a pilot.
Models are available with standard AC
or DC solenoids.
See Solenoid options on pages 4 and 5.
2.97
(75,4)
5.01
(127,3)
5.46
(138,6)
5.31
(135)
1.34
(34)
4.35
(110,5)
7.19
(182,5)
1.44
(36,6)
4X .250-20 UNC-2B X 1.00 LG. SHCS
TORQUE TO 12 LB-FT (16 Nm)
1.65
(42)
2.79
(70,8)
1.48
(37,7)
P
.49
(12,5)
1.69
(42,8)
7.64
(194,1)
PUSH TO ACTIVATE
MANUAL OVERRIDE
SOLENOID TUBE
TORQUE TO 30 LB-FT (40 Nm)
ON TUBE FLATS
(UNDERNEATH COIL)
COIL RETAINING NUT
TORQUE: HAND TIGHT
ELECTRICAL CONNECTOR TO
CONFORM TO DEUTSCH DT04-2P
SEE ADDITIONAL OPTIONS ON PAGES 4, 5
.62
(15,7)
GRIP
.40
(10)
2.75
(69,9)
6600 Series, Single Solenoid Piloted Models
5.01
(127,3)
5.46
(138,6)
5.31
(135)
4.35
(110,5)
8.38
(212,9)
1.44
(36,6)
4X .250-20 UNC-2B X 1.00 LG. SHCS
TORQUE TO 12 LB-FT (16 Nm)
1.65
(42)
2.79
(70,8)
1.48
(37,7)
P
1.39
(35,3)
1.69
(42,8)
11.25
(285,8)
PUSH TO ACTIVATE
MANUAL OVERRIDE
SOLENOID TUBE
TORQUE TO 30 LB-FT (40 Nm)
ON TUBE FLATS
(UNDERNEATH COIL)
COIL RETAINING NUT
TORQUE: HAND TIGHT
.62
(15,7)
GRIP
.40
(10)
2.75
(69,9)
1.34
(34)
2.97
(75,4)
5.99
(152,1)
ELECTRICAL CONNECTOR TO
CONFORM TO DEUTSCH DT04-2P
SEE ADDITIONAL OPTIONS ON PAGES 4, 5
663*
665*
6600 Series, Double Solenoid Piloted Models
6
Pilot Pressure:
Minimum, 500 psi (34 bar).
Maximum, 3000 psi (210 bar).
Weight (Mass):
661, 662, 664 Models, 12.9 lb (5,9 kg).
663 Models, 13.8 lb (6,3 kg).
665 Models, 14.3 lb (6,5 kg).
6800 Series, Single Direct Hydraulic Piloted Models
6800 SERIES HYDRAULIC
PILOTED MODELS
As shown, these models use a crossover
block to direct pilot pressure from
auxiliary ports “X” and “Y.
Pilot Pressure:
Minimum, 500 psi (34 bar)*
*based on zero tank pressure. As tank
pressure increases above zero, the minimum
pilot pressure must be increased equally.
Maximum, 3000 psi (210 bar).
Required Volume (to shift spool full
stroke): 0.014 in
3
(0,23cm
3
).
6800 Series, Double Direct Hydraulic Piloted Models
2.97
(75,4)
5.01
(127,3)
1.34
(34)
3.72
(94,5)
7.19
(182,5)
1.44
(36,6)
4X .250-20 UNC-2B X 1.00 LG. SHCS
TORQUE TO 12 LB-FT (16 Nm)
.49
(12,5)
1.69
(42,8)
.62
(15,7)
GRIP
.40
(10)
2.75
(69,9)
2.25
(57,2)
1.75
(44,5)
2.97
(75,4)
5.01
(127,3)
1.34
(34)
3.72
(94,5)
8.38
(212,9)
5.99
(152,1)
1.44
(36,6)
4X .250-20 UNC-2B X 1.00 LG. SHCS
TORQUE TO 12 LB-FT (16 Nm)
1.69
(42,8)
.62
(15,7)
GRIP
.40
(10)
2.75
(69,9)
2.25
(57,2)
1.75
(44,5)
683*
685*
X” and Y” Port Function
Model Port “X” Port “Y
681*
684*
Actuator A External Drain
682*
684*-R
External Drain Actuator B
685* Actuator A Actuator B
7
Weight (Mass):
681, 682, 684 Models, 18.9 lb (8,6 kg).
683 Models, 9.0 lb (4,1 kg).
685 Models, 9.4 lb (4,3 kg).
6900 Series, Single Actuator Models
6900 SERIES AIR PILOTED
MODELS
Models use a HP03 valve as a pilot.
Pilot Pressure:
Minimum, 75 psi (5 bar).
Maximum, 200 psi (14 bar).
Required Volume (to shift spool
full stroke): 0.22 in
3
(3,6 cm
3
).
2.97
(75,4)
5.01
(127,3)
1.34
(34)
3.72
(94,5)
7.19
(182,5)
.49
(12,5)
5.46
(138,6)
1.44
(36,6)
4X .250-20 UNC-2B X 1.00 LG. SHCS
TORQUE TO 12 LB-FT (16 Nm)
1.69
(42,8)
.62
(15,7)
GRIP
.40
(10)
2.75
(69,9)
1.79
(45,5)
P
.60
(15,2)
.125-27 NPT THREAD
PILOT AIR PORT
4.35
(110,5)
5.99
(152,1)
2.97
(75,4)
5.01
(127,3)
1.34
(34)
5.31
(135)
8.39
(213)
5.46
(138,6)
1.44
(36,6)
4X .250-20 UNC-2B X 1.00 LG. SHCS
TORQUE TO 12 LB-FT (16 Nm)
1.69
(42,8)
.62
(15,7)
GRIP
.40
(10)
2.75
(69,9)
1.79
(45,5)
P
.60
(15,2)
.125-27 NPT THREAD
PILOT AIR PORT
4.35
(110,5)
693*
695*
6900 Series, Double Actuator Models
8
Weight (Mass):
691, 692, 694 Models, 12.2 lb (5,5 kg).
693 Models, 12.3 lb (5,6 kg).
695 Models, 12.9 lb (5,8 kg).
Actuators
6
Solenoid Operated
8
Hydraulic Piloted
9
Air Piloted
6 6 1 5 HP05H – 115DA R – ID
XP – E 4 0
Valve Type
6
Subplate Mounted
Directional Control
Valve Size
HP05H
High Pressure
Special Mounting
Pattern
Internal Operators
1
Two Position: Spring Offset (P
B),
Actuated Position (P
A)
2
Two Position: Spring Offset (P
A),
Actuated Position (P
B)
3
Two Position: Actuated Position,
Detented
4
Two Position: Spring Centered,
Actuated Position
5
Three Position: Spring Centered,
Actuated Position
Only available with Type 25 and 26 spools.
Only available with Type 5 or 6 spools.
Spool Types
5, (25)
6, (26)
8
Code 1 or 2 operators only use
Type 25 or 26 spools. These spools
provide the same function, but are
not interchangeable with
Type 5 or 6 spools.
A
B
P
T
A
B
P
T
A
B
P
T
A
B
P
T
A
B
P
T
Design
Number
Modification
Number
Reverse Assembly Option
R
Used with Internal Operator Code 4 only.
External Pilot
XP
External Pilot (Required For All Models)
Electrical Options
AC Solenoids Deutsch Connector:
DC Solenoids Deutsch Connector:
115DA
115V/60Hz, 110V/50Hz
12DD
12VDC
230DA
230V/60Hz, 220/50Hz
24DD
24VDC
24DA
24V/60Hz, 24V/50Hz
AC Solenoids DIN Connector:
DC Solenoids DIN Connector:
115HA
115V/60Hz, 110V/50Hz
12HD
12VDC
230HA
230V/60Hz, 220/50Hz
24HD
24VDC
AC Explosion Proof:
DC Explosion Proof:
115EP
115V/60Hz
24EP
24VDC
Fits Deutsch DT04-2P Connector.
Fits EN 175301-803 (DIN 43650 Form A) Connector.
Junction box with 1/2" NPT entry for cable glands.
Seals
No
Code
Fluorocarbon (Viton
®
or Fluorel
®
)
E
EPR (Ethylene-Propylene Rubber)
General Options
ID
Internal Drain (Solenoid + Air Piloted only)
Not available with Hydraulic Piloted models.
TYPICAL MODEL CODE
9
Middle East Sales
JAFZA 1, Tower A, 11th Floor
Jebel Ali Freezone
Dubai, UAE
Tel: +971 547422353
UAEsales@dynexhydraulics.com
European Sales
Unit C5 Steel Close, Little End Road,
Eaton Socon, St Neots,
Cambs. PE19 8TT United Kingdom
Tel: +44 (0) 1480 213980
Fax: +44 (0) 01480 405662
sales@dynexhydraulics.co.uk
USA Headquarters
770 Capitol Drive
Pewaukee, WI 53072
Tel: +1 (262) 691-0300
Fax: +1 (262) 691-0312
sales@dynexhydraulics.com
Power Units & Systems
54 Nickerson Road
Ashland, MA 01721
Tel: +1 (508) 881-5110
ashland@dynexhydraulics.com
Specifications shown were in effect when
published. Since errors or omissions are possible,
contact your Dynex Sales representative or the
Dynex Sales department for the most current
specifications before ordering. Dynex reserves
the right to discontinue products or change
designs at any time without incurring any obligation.