91 100/112 ED
2/4
PS*
SERIES 21
Seals: N = standard NBR seals for mineral oils (standard)
V = FPM seals for special fluids
1 - IDENTIFICATION CODE
Electrical connection: for DIN 43650 connector
(included in the supply)
Adjustment knob
Pressure adjustment range:
2 = 3 ÷ 35 bar 6 = 10 ÷ 350 bar
4 = 6 ÷ 140 bar 8 = 20 ÷ 630 bar
Piston type pressure switch
Mounting type:
P = subplate mounting
T = threaded port 1/4” BSP
Series N. (the overall and mounting dimensions remain
unchanged from 20 to 29)
P S / /21 - K1 K
2 - HYDRAULIC FLUIDS
3 - ELECTRICAL CHARACTERISTICS
Use mineral oil-based hydraulic fluids HL or HM type, according to ISO 6743-4. For these fluids, use NBR seals (code N).
For fluids HFDR type (phosphate esters) use FPM seals (code V).
For the use of other fluid types such as HFA, HFB, HFC, please consult our technical department.
Using fluids at temperatures higher than 80 °C causes a faster degradation of the fluid and of the seals characteristics.
The fluid must be preserved in its physical and chemical characteristics.
AC DC
Power supply V 125 250 30 250
Max load on contacts
- resistive A 7 5 5 0,2
- inductive 4 2 3 0,02
Electrical insulation
> 1 M Ω at 500 Vdc
(according to CEI EN 60204)
Max switching rate switches/min 120
Protection class
IP 65
(according to CEI EN 60529)
4 - INSTALLATION
The pressure switches can be installed in any position without
impairing its correct operation. Ensure that there is no air in the
hydraulic circuit.
The subplate mounting pressure switch PSP type is fixed by means
of screws on a flat surface with planarity and roughness values
equal to or better than those indicated in the relative symbols. If the
minimum values are not observed, the fluid can easily leak between
the valve and the mounting surface.
Surface finishing