85 110/116 ED
1/4
The DXJ3 valve is a four-way servo-proportional valve
where the spool moves inside a sleeve. This valve has a
direct drive with a linear force motor resulting in high
dynamic performances which are independent of system
pressure. The spool position is controlled by a linear
transducer (LVDT) with closed loop which
ensures high precision and repeatability.
It is available in four different flow rate control
ranges up to 40 l/min, with spools with zero
overlap and a mounting surface in compliance
with ISO 4401 (CETOP RP 121H) standards.
The valve is featured by integrated electronic
based on SMD technology which ensures
standard regulations and simplifies the electric
wiring. The unit does not require any adjustment
other than the possible electronic regulation of
the zero.
Suitable for control applications with closed
loop of position, velocity and pressure. With a
loss of power or with a zero reference signal, the
spool goes automatically at rest-position. In this
position the valve has a minimum leakage,
depending on the operating pressure (see the
performances table).
0.750.75
TT
BB
31.7531.75
PP
AA
25.925.9
15.515.5
5.15.1
1
2.712.7
3131
M5M5
Ø4Ø4
Ø7.5(max)Ø7.5(max)
21.521.5
30.230.2
40.540.5
3
333
DXJ3
ELECTRO-HYDRAULIC
SERVOVALVE WITH INTEGRATED
ELECTRONICS
SERIES 10
HYDRAULIC SYMBOL
MOUNTING SURFACE OPERATING PRINCIPLE
85 110/116 ED
ISO 4401-03-02-0-05
(
CETOP 4.2-4.03-350)
SUBPLATE MOUNTING
ISO 4401-03 (CETOP 03)
p max
350 bar
Q max (see performances table)
Maximum operating pressure
Ports P - A - B
Port T
bar 350
50
Rated flow Q nom (with ∆p 70 bar P - T) l/min 5 - 10 - 20 - 40
Null leakage flow (with p = 140 bar) l/min 3% of Q nom
Hysteresis % In < 0,2
Threshold % In < 0,1
Thermal drift (with ∆T= 50°C) % In < 1,5
Response time ms ≤ 12
Vibration on the three axes g 30
Electric features see paragraph 3
Protection degree according CEI EN 60529 IP 65
Ambient temperature range °C -20 / +60
Fluid temperature range °C -20 / +80
Fluid viscosity range cSt 5 ÷ 400
Fluid contamination degree
according to ISO 4406:1999
class 17/15/12
(16/14/11 for longer life)
Recommended viscosity cSt 25
Mass kg 2,5
PERFORMANCES (with mineral oil of viscosity 36 cSt at 50°C)
85 110/116 ED
2/4
DXJ3
SERIES 10
1 - IDENTIFICATION CODE
Rated size
ISO 4401-03 (CETOP 03)
Symmetric spool
Spool with zero overlap
Spool with a linear flow rate curve
Rated flow (with p = 70 bar P - T)
05 = 5 l/min 20 = 20 l/min
10 = 10 l/min 40 = 40 l/min
Servo-proportional
valve with bushing
spool
2 - CHARACTERISTIC CURVES (measured with viscosity of 36 cSt at 50°C)
REFERENCE / FLOW RATE CURVE FLOW RATE CURVE ACCORDING TO ∆P
Typical flow rate curves at constant ∆p = 70 bar P-T according to the
reference signal.
NOTE: with positive reference signal connected to pin D the
valve regulates P - A / B - T.
The diagram states the maximum valve controlled flow rate
according to the pressure drop between the P and T ports.
The diagram shows the valve pressure gain, expressed as % of the
ratio between the port pressure variation in A or B (
p AB) and the
P system pressure, according to the reference signal. In practice,
the pressure gain states the valve reaction towards external
disturbances aimed at changing the actuator position.
PRESSURE GAIN
Reference signal [%]
D X J 3 - D 0 L / 10 / E0 K11
Integrated electronics and
position feedback
Reference signal [%]
Seals:
N = NBR seals for mineral oil (standard)
V = FPM seals for special fluids
Series No. (from 10 to 19 sizes and mounting
dimensions remain unchanged)
Reference signal: ±10V (other
signals available on request)
6 + PE pole connector
85 110/116 ED
3/4
DXJ3
SERIES 10
3 - ELECTRICAL FEATURES
CONNECTION WIRING
RESPONSE TIME FREQUENCY RESPONSE
Signal
± 10 %
Signal ± 90 %
% Spool Stroke
Frequency [Hz]
Amplitude [dB]
Phase lag [degrees]
NOTE 1: The input stage is a differential amplifier. With positive reference signal connected to pin D, valve opening P - A e B - T is achieved.
With a zero reference signal the spool is in centred position. The spool stroke is proportional to U
D
- U
E
. If only one command signal is available
(single-end), pin E must be connected to pin B (0V ground).
NOTE 2: The spool position value can be measured at pin F (see diagram right).
The position signal output goes from 4 to 20 mA. The centered position is at 12 mA,
while 20 mA corresponds to 100% valve opening P - A and B - T. This monitoring allows
to detect a cable break when I
F
= 0V.
General requirements:
External fuse = 1,6 A
l
Minimum cross-section of all leads ≈0,75 mm
2
When making electric connections to the valve (shield, protective earth) appropriate measures must be taken to ensure that locally
different earth potentials do not results in excessive ground currents.
The differential and the spool position signal lines must be connected to the mating connector housing at valve side and to the 0V (signal
ground) at cabinet side.
EMC: meets the requirements of EN 55011:1998, class B, and the immunity regulation according to EN 61000-6-2:1998
valve side
spool stroke range
Pin Values Function NOTES
A 24 VDC Supply From 19 to 32 VDC I
A MAX
= 1,2 A
B 0 V Signal ground 0 V
C ---- Not used ----
D ± 10 V Input rated command R
e
= 10 kΩ (see NOTE 1)
E 0 V Input rated command ----
F 4 ÷ 20 mA Spool position R
L
= from 300 to 500 Ω (see NOTE 2)
PE ---- Protective earth ----
85 110/116 ED
4/4
DUPLOMATIC OLEODINAMICA S.p.A.
20015 PARABIAGO (MI)  Via M. Re Depaolini 24
Tel. +39 0331.895.111
Fax +39 0331.895.339
www.duplomatic.com  e-mail: sales.exp@duplomatic.com
DXJ3
SERIES 10
REPRODUCTION IS FORBIDDEN. THE COMPANY RESERVES THE RIGHT TO APPLY ANY MODIFICATIONS.
DUPLOMATIC OLEODINAMICA S.p.A.
20015 PARABIAGO (MI)  Via M. Re Depaolini 24
Tel. +39 0331.895.111
Fax +39 0331.895.339
www.duplomatic.com  e-mail: sales.exp@duplomatic.com
6 - OVERALL AND MOUNTING DIMENSIONS
5 - INSTALLATION
The DXJ3 valve can be installed in any position without impairing its
correct operation.
The valve is fixed by means of screws on a flat surface with
planarity between 0,01 mm over 100 mm and roughness
R
a
< 0,8 µm. If the minimum values are not observed, the fluid can
easily leak between the valve and the mounting surface. While
mounting pay attention to the environment and valve cleanliness.
Surface finishing
dimensions in mm
Fastening bolts: 4 bolts SHC M5 x 55 - ISO 4762
Torque: 8,5 Nm
4 - HYDRAULIC FLUIDS
Use mineral oil-based hydraulic fluids HL or HM type, according to ISO 6743-4. For these fluids, use NBR seals. For fluids HFDR type
(phosphate esters) use FPM seals (code V). For the use of other kinds of fluid such as HFA, HFB, HFC, please consult our technical
department. Using fluids at temperatures higher than 80 °C causes a faster degradation of the fluid and of the seals characteristics.
The fluid must be preserved in its physical and chemical characteristics.
1 Mounting surface with sealing rings:
N. 4 OR type 2037 (9.25x1.78) - 90 Shore
N. 1 OR type 2031 (7.66x1.78) - 90 Shore
2 Integrated electronics
3 Linear force motor
4 Electric connector 7 pins DIN 43563 - IP67
PG11 EX7S/L/10 cod. 3890000003
(to be ordered separately)