83 260/112 ED
5/8
DSE5
SERIES 10
4 - HYDRAULIC FLUIDS
Use mineral oil-based hydraulic fluids HL or HM type, according to ISO 6743-4. For these fluids, use NBR seals (code N). For fluids HFDR type
(phosphate esters) use FPM seals (code V). For the use of other fluid types such as HFA, HFB, HFC, please consult our technical department.
Using fluids at temperatures higher than 80 °C causes a faster degradation of the fluid and of the seals characteristics.
The fluid must be preserved in its physical and chemical characteristics.
5 - ELECTRICAL CHARACTERISTICS
6 - STEP RESPONSE
(measured with mineral oil with viscosity of
36 cSt at 50°C with the relative electronic control units)
7 - INSTALLATION
Proportional solenoid
The proportional solenoid comprises two parts: tube and coil.
The tube, screwed to the valve body, contains the armature which
is designed to maintain friction to a minimum thereby reducing
hysteresis.
The coil is mounted on the tube secured by means of a lock nut.
It can be rotated through 360° depending on installation clearances.
Step response is the time taken for the valve to reach 90% of the
set position value following a step change of reference signal.
The table shows typical response times tested with spool type C60
and ∆p = 20 bar P-T.
DSE5 valves can be installed in any position without impairing
correct operation.
Ensure that there is no air in the hydraulic circuit.
Valves are fixed by means of screws or tie rods on a flat surface
with planarity and roughness equal to or better than those indicated
in the relative symbols. If minimum values are not observed fluid
can easily leak between the valve and support surface.
Surface finishing
NOMINAL VOLTAGE VDC 12 24
RESISTANCE (at 20°C)
Ω
3 - 3.4 8.65
MAXIMUM CURRENT A 2.6 1.6
DUTY CYCLE 100%
ELECTROMAGNETIC
COMPATIBILITY (EMC)
according to
2004/108/CE
CLASS OF PROTECTION:
atmospheric agents (CEI EN 60529)
coil insulation (VDE 0580)
Impregnation
IP 65
class H
class F
REFERENCE
SIGNAL STEP
0→100% 100%→0
Step response [ms]
DSE5-A*
DSE5-C*
50 40