81 515/116 ED
1/8
ZDE3K*are direct operated pressure reducing valves,
with electric proportional control, with ISO 4401-03
mounting surface.
They are compliant with ATEX, IECEx and INMETRO
requirements and are suitable for use in potentially
explosive atmospheres, for surface plants or mines.
A low temperature version (up to - 40 °C) is also
available.
The valves are used to reduce pressure in the
secondary circuit branches thus ensuring stability of
controlled pressure in the event of variations of the flow
rate through the valve.
ZDE3K* valves are supplied with a nishing surface
treatment (zinc-nickel) suitable to ensure a salt spray
resistance up to 600 hours.
Details for classification, operating temperatures
and electrical characteristics are in the technical
data sheet 02 500 ‘Explosion proof classification’.
ZDE3K*
EXPLOSION-PROOF
PRESSURE REDUCING VALVES
ATEX, IECEx, INMETRO
SERIES 10
HYDRAULIC SYMBOLS
OPERATING PRINCIPLE
81 515/116 ED
SUBPLATE MOUNTING
ISO 4401-03
p max
100 bar
Q max 15 l/min
Pressure allowed in P port bar 30 ÷ 100
Pressure allowed in T port (see par. 3) bar 0 ÷ 30
Controlled pressure bar 23
Maximum flow l/min 15
Step response ms 30
Hysteresis (with PWM 200 Hz) % of p nom < 4%
Repeatability % of p nom < ±1%
Electrical characteristic see paragraph 4
Operating temperatures
(ambient and fluid)
see data sheet 02 500
Fluid viscosity range cSt 10 ÷ 400
Fluid contamination degree
According to ISO 4406:1999 class 18/16/13
Recommended viscosity cSt 25
Mass: single solenoid valve
double solenoid valve
kg
1,9
2,8
PERFORMANCES
(obtained with mineral oil with viscosity of 36 cSt at 50°C and electronic control card)
ZDE3K*-D
ZDE3K*-SB
ZDE3K*-SA
81 515/116 ED
2/8
ZDE3K*
SERIES 10
1 - IDENTIFICATION CODE
Series No.
(from 30 to 39 sizes and mounting dimensions
remain unchanged)
Electric proportional
control
Size ISO 4401-03
Solenoids:
D = pressure reduction in A and B ports
SA = pressure reduction in A port (solenoid on side B)
SB = pressure reduction in B port (solenoid on side A)
Pressure reducing
valve:
Option: /T5
version in T5
temperature class.
Omit if not required.
Nominal solenoid voltage
D12 = 12 V DC
D24 = 24 V DC
Explosion-proof certification:
See table 1.1
NOTE: zinc-nickel standard finishing surface treatment.
Test operated according to UNI EN ISO 9227 standards and test
evaluation operated according to UNI EN ISO 10289 standards.
Connection type for cable gland
upper connection:
T01 = M20x1.5 - ISO 261
T02 = Gk 1/2 - UNI EN 10226 -2
not available for INMETRO
T03 = 1/2” NPT - ANSI B1.20.1 (ex ANSI B2.1)
side connection:
S01 = M20x1.5 - ISO 261
S02 = Gk 1/2 - UNI EN 10226 -2
not available for INMETRO
S03 = 1/2” NPT - ANSI B1.20.1 (ex ANSI B2.1)
S04 = M16x1.5 - ISO 261
Seals:
For temperature range -20 / +80 °C
N = NBR seals for mineral oil (standard)
V = FPM seals for special fluids
For temperature range -40 / +80 °C
NL = seal for low temperatures (for mineral oil)
Coil electrical connection: by terminal block
Manual override:
CM = boot protected
standard for both N and V seals
not available for NL seals
CB = blind ring nut
standard for NL seals
available upon request for both N
and V seals
see paragraph 8
Z D E 3 - / 10 - /K9
1.1 - Names of valves per certification
ATEX IECEx INMETRO
for gases
for dusts
KD2 II 2GD KXD2
IECEx Gb
IECEx Db
KBD2
INMETRO Gb
INMETRO Db
for mines KDM2 I M2 KXDM2 IECEx Mb KBDM2 INMETRO Mb
NOTE: Refer to the technical data sheet 02 500 for marking, operating temperatures and available versions.
3 - STEP RESPONSE
(obtained with mineral oil with viscosity of 36 cSt at 50°C and electronic control card)
Step response is the time taken for the valve to reach 90% of the
set pressure value following a step change of reference signal.
The table illustrates typical step response times measured with
input flow rate of Q = 5 l/min and p = 50 bar.
81 515/116 ED
3/8
ZDE3K*
SERIES 10
PRESSURE CONTROL p=f (I) PRESSURE VARIATION p = f(Q)
SA and SB versions pressure regulation is less than 0.5 bar. The curves have been obtained with inlet pressure 100 bar.
PRESSURE DROP p = f(Q)
2 - CHARACTERISTIC CURVES
(obtained with ZDE3K*-D/10N-D24K9T01/CM with PWM 100Hz and oil with viscosity 36 cSt at 50°C)
REFERENCE SIGNAL STEP
0 → 100% 100% → 0
response time [ms] 30 30
DUTY CYCLE
100%
ELECTROMAGNETIC COMPATIBILITY
(EMC)
According to
2014/30/EU
CLASS OF PROTECTION:
Atmospheric agents
Coil insulation (VDE 0580)
IP66 / IP68
class H
4 - ELECTRICAL CHARACTERISTICS
(values ± 5%)
NOMINAL VOLTAGE
V DC
12 24
RESISTANCE (at 20°C)
3.4 15.6
NOMINAL CURRENT
A 1.88 0.86
PWM FREQUENCY
Hz 200 100
81 515/116 ED
4/8
ZDE3K*
SERIES 10
4.2 - Electrical diagram 4.3 - Overcurrent fuse and switch-off voltage peak
Upstream of each valve, an appropriate fuse (max 3 x In according
to IEC 60127) or a protective motor switch with short-circuit and
thermal instantaneous tripping, as short-circuit protection, must be
connected. The cut-off power of the fuse must correspond or
exceed the short circuit current of the supply source.
The fuse or the protective motor must be placed outside the
dangerous area or they must be protected with an explosion-proof
covering.
In order to safeguard the electronic device to which the valve is
connected, there is a protection circuit in the coil, that reduces
voltage peaks, which can occur when inductances are switched off.
The table shows the type of fuse recommended according to the
nominal voltage of the valve and to the value of the voltage peaks
reduction.
Characteristics of the cables connectable for wiring are indicated in the table below:
Cables for wiring must be non-armoured cables, with external covering sheath and must be suitable for use in environments with temperatures
from - 20 °C to +110 °C (for valves either with N or V seals) or from - 40 °C to +110 °C (for valves with NL seals).
Cable glands (which must be ordered separately, see paragraph 10) allow to use cables with external diameter between 8 and 10 mm.
Function Cable section
Operating voltage cables connection max 2.5 mm²
Connection for internal grounding point max 2.5 mm²
Connection for external equipotential grounding point max 6 mm²
Coil type
Nominal
voltage
[V]
Rated
current
[A]
Recommended pre-fuse characteristics
medium time-lag according to DIN 41571
[A]
Maximum voltage
value upon switch off
[V]
Suppressor circuit
D12 12 1,88 2,5 - 49
Transient voltage
suppressor
bidirectional
D24 24 0,86 1,25 - 49
recommended
upstream fuse
(see par. 4.3)
4.1 - Wiring
In order to realise the electrical connection of the coil, it is necessary to access the terminal block (1) unscrewing the 4 screws (2) that fasten
the cover (3) with the box (4) that contains the terminal block.
The electrical connection is polarity-independent.
By doing electrical connection it is important to connect also the grounding point (5) in the terminal block box (M4 screws), through suitable
conductors with the general grounding line of the system.
On the external body of the coil there is a grounding point (6) (M4 screw) that allow to ensure equipotentiality between the valve and the
general grounding line of the system; connecting this point the regulation of the EN 13463-1 standard, that impose to verify the equipotentiality
of the elements included in a potentially explosive environment (the maximum resistance between the elements must be 100 ), is
guaranteed.
At the end of the electrical wiring, it is necessary to reassemble the cover (3) on the box (4), checking the correct positioning of the seal located
in the cover seat and fastening the 4 M5 screws with a torque of 4.9 ÷ 6 Nm.
Electrical wiring must be done following in compliance with standards about protection against explosion hazards.
*K9T* *K9S*
81 515/116 ED
5/8
ZDE3K*
SERIES 10
4
6
47
88.5
65
255
A
P
T
B
7.5
11. 2
1
2
4
7
45
1.5
5
9
5
75
3
22.5
67.3
109.9
4
6
6
65
168
22.5
45
1.5
8
51
5 - OVERALL AND MOUNTING DIMENSIONS
dimensions in mm
ZDE3K*- D/10*-*K9T */CM
1 Mounting surface with sealing rings
4 OR type 2037 (9.25x1.78) - 90 Shore
2 Explosion-proof coil
3 Minimum clear space required
4 Manual override, boot protected
(standard for both N and V seals)
for blind ring nut dimensions (standard
with NL seals) see par. 8
5 Terminal for supplementary GND
connection
6 Upper port for cable gland
7 Cable gland
To be ordered separately, see par. 9
8 Side port for cable gland
Solenoid position
for SA versions
ZDE3K*-*/10*-*K9S*/CM
ZDE3K*- SB*/10*-*K9T */CM
Side port type A
S01, S04 60.5
S02, S03 60
Fastening of single valve: 4 SHC screws ISO 4762 M5x30
Tightening torque: 5 Nm (A8.8 screws)
Threads of mounting holes: M5x10
8
A
80.6
7
7
81 515/116 ED
6/8
ZDE3K*
SERIES 10
8 - MANUAL OVERRIDE CB
CB - Blind ring nut
The metal ring nut protects the solenoid tube from atmospheric
agents and isolates the manual override from accidental
operations. The ring nut is tightened on a threaded fastener
that keeps the coil in its position even without the ring nut.
To access the manual override loose the ring nut and remove
it; then reassemble hand tightening, until it stops.
Activate the manual override always and only with non-
sparking tools suitable for use in potentially explosive
atmospheres.
More information on safe use of explosion-proof components
are provided in the instruction manual, always supplied with
the valve.
CAUTION!: The manual override doesn't allow any
proportional regulation; indeed using this kind of
override, the main stage spool will open
completely and the whole inlet pressure will pass
through A or B line.
78.5
6 - HYDRAULIC FLUIDS
Use mineral oil-based hydraulic fluids HL or HM type, according to ISO 6743-4. For these fluids, use NBR seals. For fluids HFDR type
(phosphate esters) use FPM seals (code V). For the use of other fluid types such as HFA, HFB, HFC, please consult our technical department.
Using fluids at temperatures higher than 80 °C causes a faster degradation of the fluid and of the seals characteristics. The fluid must be
preserved in its physical and chemical characteristics.
7 - INSTALLATION
Installation must adheres to instructions reported in the Use and Maintenance manual, always attached to the valve.
Unauthorized interventions can be harmful to people and goods because of the explosion hazards present in potentially
explosive atmospheres.
The valves can be installed in any position without impairing correct operation.
Ensure that there is no air in the hydraulic circuit.
Connect the valve T port directly to the tank. Add any backpressure value detected in the T line to
the reduced pressure value.
In the T line the maximum admissible backpressure is 30 bar, under operational conditions.
Valves are fixed by means of screws or tie rods on a flat surface with planarity and roughness equal
to or better than those indicated in the relative symbols. If minimum values are not observed fluid
can easily leak between the valve and support surface.
Surface finishing
81 515/116 ED
7/8
ZDE3K*
SERIES 10
9 - CABLE GLANDS
Cable glands must be ordered separately; Duplomatic offers some types of cable glands with the following features:
• version for non-armoured cable, external seal on the cable (suitable for Ø 8 ÷10 mm cables);
ATEX II 2GD, I M2; IECEx Gb, Db, Mb; INMETRO Gb, Db, Mb certified
• cable gland material: nickel brass
• rubber tip material: silicone
• ambient temperature range: -70ºC ÷ +220ºC
• protection degree: IP66/IP68
• tightening torque: 15 Nm
To order, list the description and the code of the version chosen from among those listed below:
Description: CGK2/NB-01/10
Code: 3908108001
M20x1.5 - ISO 261 male thread, suitable for coils with T01 and S01
connections. It is supplied equipped with silicone seal, that must be
assembled between the cable gland and the coil, so as to ensure
IP66/IP68 protection degree.
Description: CGK2/NB-02/10
Code: 3908108002
Gk 1/2 - UNI EN 10226-2 male thread, suitable for coils with T02
and S02 connections. The customer must apply LOCTITE® 243™
threadlocker or similar between the cable gland connection thread
and the coil in order to ensure IP66/IP68 protection degree.
Description: CGK2/NB-03/10
Code: 3908108003
1/2” NPT - ANSI B1.20.1 (ex ANSI B2.1), suitable for coils with T03
and S03 connections. The customer must apply LOCTITE® 243™
threadlocker or similar between the cable gland connection thread
and the coil in order to ensure IP66/IP68 protection degree.
Description: CGK2/NB-04/10
Code: 3908108004
M16x1.5 - ISO 261 male thread, suitable for coils with S04
connection. It is supplied equipped with silicone seal, that must be
assembled between the cable gland and the coil, so as to ensure
IP66/IP68 protection degree.
EDM-M111 for solenoid 24V DC
DIN EN 50022
rail mounting
see cat.
89 250
EDM-M142 for solenoid 12V DC
ZDE3K*- D*
ZDE3K*- SA* ZDE3K*- SB*
EDM-M211 for solenoid 24V DC
DIN EN 50022
rail mounting
see cat.
89 250
EDM-M242 for solenoid 12V DC
10 - ELECTRONIC CONTROL UNITS
11 - SUBPLATES
(see catalogue 51 000)
Type PMMD-AI3G with rear ports
Type PMMD-AL3G with side ports
P, T, A, B port threading: 3/8” BSP
NOTE: Subplates (to be ordered separately) do not contain
neither aluminium nor magnesium at a higher rate than the
value allowed by norms according to ATEX directive for
categories II 2GD and I M2 .
The user must take care and make a complete assessment
of the ignition risk, that can occur from the relative use in
potentially explosive environments.
NOTE: electronic control units offered are not explosion
proof certified; therefore, they must be installed outside
the classified area.
81 515/116 ED
8/8
DUPLOMATIC OLEODINAMICA S.p.A.
20015 PARABIAGO (MI)  Via M. Re Depaolini 24
Tel. +39 0331.895.111
Fax +39 0331.895.339
www.duplomatic.com  e-mail: sales.exp@duplomatic.com
ZDE3K*
SERIES 10
REPRODUCTION IS FORBIDDEN. THE COMPANY RESERVES THE RIGHT TO APPLY ANY MODIFICATIONS.
02 500/116 ED
1/6
02 500/116 ED
EXPLOSION-PROOF
CLASSIFICATION
for
SOLENOID ANDPROPORTIONALVALVES
ref. catalogues:
pressure valves
RQM*K*-P* 21 515
PRE(D)*K* 81 315
ZDE3K* 81 515
DZCE*K* 81 605
directional valves
D*K* 41 515
DS(P)E*K* 83 510
GENERAL INFO
This informative technical datasheet displays information about
classification and marking of Duplomatic explosion-proof valves
range.
Duplomatic offers valves with the following certifications:
ATEX II 2G II 2D I M2
IECEx Gb Db Mb
INMETRO Gb Db Mb
Instructions for use and maintenance can be found in the related
manuals, always supplied toghether with valves.
02 500/116 ED
2/6
DZCE*K*
SERIES 11
1 - ATEX CLASSIFICATION AND TEMPERATURES
Duplomatic certificates the combination valve-coil for the valves suitable for application and installation in potentially explosive atmospheres,
according to ATEX directive; the supply always includes the declaration of conformity to the directive and the operating and maintenance
manual, that contains all the information needed for a correct use of the valve in potentially explosive environments.
Coils assembled on these valves have been separately certified according to ATEX directive and so they are suitable for use in potentially
explosive atmospheres.
1.1 - ATEX classification for valves
Type examination certificate: CEC 13 ATEX 030-REV.2
The valves are suitable for applications and installations in potentially explosive atmospheres that fall within:
1.2 - ATEX marking for valves
ATEX II 2G
ATEX II 2D
*KD2
equipment intended for use in areas in which explosive atmospheres caused by gases, vapours, mists or
air/dust mixtures are likely to occur occasionally.
ATEX I M2 *KDM2
equipment intended for use in underground parts of mines as well as those parts of surface installations of
such mines likely to be endangered by firedamp and/or combustible dust.
This equipment is intended to be de-energised in the event of an explosive atmosphere.
Specific marking as ATEX 2014/34/EU directive and related technical specifications
Temperature class / max surface temperature
see par. 1.5
Protection degree from atmospheric agents
according to IEC EN 60529
(this field is not intended for category 2G)
Ambient temperature range
EPL protection level for electrical devices
II
T4__
M
b
IP66/IP68
(- °C Ta + °C)
Group:
I = mining equipment
II = for surface plants
valve
code
N and V seals NL seals
*KD2
for gas
II 2G IIC T4 Gb (-20°C Ta +80°C) II 2G IIC T4 Gb (-40°C Ta +80°C)
for dusts
II 2D IIIC T154°C Db IP66/IP68 (-20°C Ta +80°C) II 2D IIIC T154°C Db IP66/IP68 (-40°C Ta +80°C)
*KD2 /T5
for gas
II 2G IIC T5 Gb (-20°C Ta +55°C) II 2G IIC T5 Gb (-40°C Ta +55°C)
for dusts
II 2D IIIC T129°C Db IP66/IP68 (-20°C Ta +55°C) II 2D IIIC T129°C Db IP66/IP68 (-40°C Ta +55°C)
*KDM2 mining
I M2 I T150°C Mb IP66/68 (-20°C Ta +75°C) I M2 I T150°C Mb IP66/68 (-40°C Ta +75°C)
Group of gas / dusts for which the equipment is certified
I = for mining: firedamp and/or combustible dusts
IIC = for gas - eligible also for group IIA and IIB
IIIC = for dusts - eligible also for group IIIA and IIIB
Category of protection:
M2 = (mining) high protection
This equipment is intended to be de-energised
in the event of an explosive atmosphere
2G = (surface, atmosphere with gas)
high protection
eligible for category 2 (zone 1)
automatically liable for category 3 (zone 2)
2D = (surface, atmosphere with dusts)
high protection
eligible for category 2 (zone 21)
automatically liable for category 3 (zone 22)
02 500/116 ED
3/6
DZCE*K*
SERIES 11
Group:
I = mining equipment
II = equipment for surface plants
Specific marking as ATEX 2014/34/EU directive and related technical specifications
Temperature class / max surface temperature
see par. 1.5
Protection degree from atmospheric agents
according to IEC EN 60529 (this field is not
intended for category 2G)
Ambient temperature range
EPL protection level for electrical devices
Ex
d
II
T4__
Mb
IP66/IP68
(- °C Ta + °C)
1.5 -
Operat
ing t
emperat
ures
These valves are classified according to their maximum surface temperature (EN 13463-1), which must be lower than the ignition temperature
o
f th
e
g
a
s
e
s
, v
a
p
o
rs
a
n
d
d
u
s
ts
fo
r w
h
i
c
h
th
e
a
re
a
i
n
w
h
i
ch they will be used is classified.
Th
e
v
a
l
v
e
s
i
n
g
ro
u
p
II c
a
n
a
l
s
o
b
e
u
s
e
d
fo
r l
e
s
s
l
i
m
i
ti
n
g
temperature classes (surface temperature allowed higher).
temperature range N and V seals NL seals Temperature class eligible also for
ATEX II 2G
ATEX II 2D
*KD2
of ambient
-20 / +80 °C - 40 / +80 °C
T4 (gas)
T154°C (dusts)
T3, T2, T1
T200°C and higher
of fluid
*KD2 /T5
of ambient -20 / +55 °C - 40 / +55 °C
T5 (gas)
T129°C (dusts)
T4, T3, T2, T1
T135°C and higher
of fluid -20 / +60 °C - 40 / +60 °C
ATEX I M2 *KDM2
of ambient
-20 / +75 °C - 40 / +75 °C T150°C -
of fluid
for valve type
*KD2
for gas
II 2G Ex d IIC T4 Gb (-40°C Ta +80°C)
for dusts
II 2D Ex tb IIIC T154°C Db IP66/IP68 (-40°C Ta +80°C)
for valve type
*KD2 /T5
for gas
II 2G Ex d IIC T5 Gb (-40°C Ta +55°C)
for dusts
II 2D Ex tb IIIC T129°C Db IP66/IP68 (-40°C Ta +55°C)
for valve type
*KDM2
mining
I M2 Ex d I T150°C Mb IP66/IP68 (- 40°C Ta +75°C)
Group of gas / dusts for which the equipment is certified
I = for mining: firedamp and/or combustible dusts
IIC = for gas - eligible also for group IIA and IIB
IIIC = for dusts - eligible also for group IIIA and IIIB
Category of protection:
M2 = (mining) high protection
This equipment is intended to be de-energised
in the event of an explosive atmosphere
2G = (surface, atmosphere with gas)
high protection
eligible for category 2 (zone 1)
automatically liable for category 3 (zone 2)
2D = (surface, atmosphere with dusts)
high protection
eligible for category 2 (zone 21)
automatically liable for category 3 (zone 22)
1.3 - ATEX classification of the coils
The coil of the explosion-proof valves is ATEX certified itself an as such is identified with its own tag, carries the relative ATEX marking.
The mechanical construction of the coil housing is made in order to ensure its resistance to possible internal explosion and to avoid
any explosion propagation to the outside environment, matching an “Ex d” type protection (explosion-proof coil).
Moreover, the solenoid is designed to maintain its surface temperature below the limits specified to the relevant class.
1.4 - ATEX marking on coils
Coil protection type:
d = flameproof enclosure
tb = protection from dust by enclosure
02 500/116 ED
4/6
DZCE*K*
SERIES 11
Protection type:
db = flameproof enclosure
tb = protection from dust by enclosure
2.3 -
Oper
ati
ng temp
er
at
ur
es
These valves are classified according to their maximum surface temperature (EN 13463-1), which must be lower than the ignition temperature
o
f th
e
g
a
s
e
s
, v
a
p
o
rs
a
n
d
d
u
s
ts
fo
r w
h
i
c
h
th
e
a
re
a
i
n
w
h
i
c
h
they will be used is classified.
Va
l
v
e
s
fo
r s
u
rfa
c
e
p
l
a
n
ts
c
a
n
a
l
s
o
b
e
u
s
e
d
fo
r l
e
s
s
l
i
m
i
ti
n
g
temperature classes (higher surface temperature allowed).
temperature range N and V seals NL seals Temperature class eligible also for
IECEx Gb
IECEx Db
*KXD2
of ambient
-20 / +80 °C - 40 / +80 °C
T4 (gas)
T135°C (dusts)
T3, T2, T1
T200°C and higher
of fluid
*KXD2 /T5
of ambient -20 / +55 °C - 40 / +55 °C
T5 (gas)
T100°C (dusts)
T4, T3, T2, T1
T135°C and higher
of fluid -20 / +60 °C - 40 / +60 °C
IECEx Mb *KXDM2
of ambient
-20 / +80 °C - 40 / +80 °C - -
of fluid
2 - IECEx CLASSIFICATION AND TEMPERATURES
The IECEx certification requires the classification of the electrical equipment only.
Duplomatic supplies valves with IECEx certified coils, suitable for application and installation in potentially explosive atmospheres. The
mechanical construction of the coil housing is made in order to ensure its resistance to possible internal explosion and to avoid any explosion
propagation to the outside environment, matching an “Ex db” type protection (explosion-proof coil).
Moreover, the solenoid is designed to maintain its surface temperature below the limits specified to the relevant class.
The supply always includes the operating and maintenance manual, that contains all the information needed for a correct use of the
valve in potentially explosive environment.
2.1 - IECEx classification
Certificate of conformity (CoC): IECEx TUN 15.0028X
The valves are suitable for applications and installations in potentially explosive atmospheres that fall within:
2.2 - IECEx marking
There is a plate with the IECEx mark on each coil.
IECEx Gb
IECEx Db
*KXD2
equipment intended for use in areas in which explosive atmospheres caused by gases, vapours, mists or
air/dust mixtures are likely to occur occasionally.
IECEx Mb *KXDM2
equipment intended for use in underground parts of mines as well as those parts of surface installations of
such mines likely to be endangered by firedamp and/or combustible dust.
This equipment is intended to be de-energised in the event of an explosive atmosphere.
Conformity marking to the IECEx certification scheme
Temperature class / max surface temperature see par. 2.3
Ambient temperature range
EPL - protection level for electrical devices
Mb = for mines - having a "high" level of protection, which has
sufficient security that it is unlikely to become a source of ignition in
normal operation or during expected malfunctions in the time span
between there being an outbreak of gas and the equipment being de-
energized.
Gb = for explosive gas atmospheres - having a "high" level of
protection, which is not a source of ignition in normal operation or
during expected malfunctions.
Db = equipment for explosive dust atmospheres - having a "high" level
of protection, which is not a source of ignition in normal operation or
during expected malfunctions
*KXD2
valves
for gas Ex db IIC T4 Gb (-40°C Ta +80°C)
for dusts Ex tb IIIC T135°C Db (-40°C Ta +80°C)
*KXD2 /T5
valves
for gas Ex db IIC T5 Gb (-40°C Ta +55°C)
for dusts Ex tb IIIC T100°C Db (-40°C Ta +55°C)
*KDM2
valves
mining Ex db I Mb (-40°C Ta +80°C)
Group of gas / dusts for which the equipment is certified
I = for mining: firedamp and/or combustible dusts
IIC = for gas - eligible also for group IIA and IIB
IIIC = for dusts - eligible also for group IIIA and IIIB
Ex
d
II
T4__
M (- °C Ta + °C)
02 500/116 ED
5/6
DZCE*K*
SERIES 11
Protection type:
d = flameproof enclosure
tb = protection from dust by enclosure
3.3 -
Oper
ati
ng temp
er
at
ur
es
These valves are classified according to their maximum surface temperature (EN 13463-1), which must be lower than the ignition temperature
o
f th
e
g
a
s
e
s
, v
a
p
o
rs
a
n
d
d
u
s
ts
fo
r w
h
i
c
h
th
e
a
re
a
i
n
w
h
i
ch they will be used is classified.
Va
l
v
e
s
fo
r s
u
rfa
c
e
p
l
a
n
ts
c
a
n
a
l
s
o
b
e
u
s
e
d
fo
r l
e
s
s
l
i
m
i
ti
ng temperature classes (higher surface temperature allowed).
temperature range N and V seals NL seals Temperature class eligible also for
INMETRO Gb
INMETRO Db
*KBD2
of ambient
-20 / +80 °C - 40 / +80 °C
T4 (gas)
T154°C (dusts)
T3, T2, T1
T200°C and higher
of fluid
*KBD2 /T5
of ambient -20 / +55 °C - 40 / +55 °C
T5 (gas)
T129°C (dusts)
T4, T3, T2, T1
T135°C and higher
of fluid -20 / +60 °C - 40 / +60 °C
INMETRO Mb *KBDM2
of ambient
-20 / +75 °C - 40 / +75 °C T150°C -
of fluid
3 - INMETRO CLASSIFICATION AND TEMPERATURES
The INMETRO certification requires the classification of the electrical equipment only.
Duplomatic supplies valves with INMETRO certified coils, suitable for application and installation in potentially explosive atmospheres.
The mechanical construction of the coil housing is made in order to ensure its resistance to possible internal explosion and to avoid any
explosion propagation to the outside environment, matching an “Ex d” type protection (explosion-proof coil).
Moreover, the solenoid is designed to maintain its surface temperature below the limits specified to the relevant class.
The supply always includes the operating and maintenance manual, that contains all the information needed for a correct use of the
valve in potentially explosive environment.
3.1 - INMETRO classification
Certificate of conformity: DNV 15.0094 X
The valves are suitable for applications and installations in potentially explosive atmospheres that fall within:
3.2 - INMETRO marking
There is a plate with the INMETRO mark on each coil.
Conformity marking to the INMETRO certification scheme
Temperature class / max surface temperature see par. 3.3
Ambient temperature range
EPL - protection level for electrical devices
Mb = for mines - having a "high" level of protection, which has
sufficient security that it is unlikely to become a source of ignition in
normal operation or during expected malfunctions in the time span
between there being an outbreak of gas and the equipment being de-
energized.
Gb = for explosive gas atmospheres - having a "high" level of
protection, which is not a source of ignition in normal operation or
during expected malfunctions.
Db = equipment for explosive dust atmospheres - having a "high" level
of protection, which is not a source of ignition in normal operation or
during expected malfunctions
*KBD2
valves
for gas Ex d IIC T4 Gb (-40°C Ta +80°C)
for dusts Ex tb IIIC T154°C Db IP66/IP68 (-40°C Ta +80°C)
*KBD2 /T5
valves
for gas Ex d IIC T5 Gb (-40°C Ta +55°C)
for dusts Ex tb IIIC T129°C Db IP66/IP68 (-40°C Ta +55°C)
*KBDM2
valves
mining Ex d I T150° Mb IP66/IP68 (-40°C Ta +75°C)
Group of gas / dusts for which the equipment is certified
I = for mining: firedamp and/or combustible dusts
IIC = for gas - eligible also for group IIA and IIB
IIIC = for dusts - eligible also for group IIIA and IIIB
Ex
d
II T4__ M
INMETRO Gb
INMETRO Db
*KBD2
equipment intended for use in areas in which explosive atmospheres caused by gases, vapours, mists or
air/dust mixtures are likely to occur occasionally.
INMETRO Mb *KBDM2
equipment intended for use in underground parts of mines as well as those parts of surface installations of
such mines likely to be endangered by firedamp and/or combustible dust.
This equipment is intended to be de-energised in the event of an explosive atmosphere.
(- °C Ta + °C)
Protection degree from atmospheric agents according to
IEC EN 60529 (this field is not intended for gases)
IP66/IP68
02 500/116 ED
6/6
DUPLOMATIC OLEODINAMICA S.p.A.