66 200/117 ED
2/4
RPC1*/M
SERIES 10
1 - IDENTIFICATION CODE
2 - CHARACTERISTIC CURVES
(values obtained with viscosity of 36 cSt at 50°C)
FLOW ADJUSTMENT PRESSURE ADJUSTMENT
(PCT3 version)
1) pressure drops on free lines
2) pressure drops through check valve
3) pressure drops through the backpressure
valve (PCT3 version)
PRESSURE DROPS ∆p - Q
KNOB TURNS
Seals: omit for mineral oils
V = viton for special fluids
M1 = adjustment knob only for PCT3
version (omit for adjustment with
countersunk hex screw)
Series No. (the overall and
mounting dimensions remain
unchanged from 10 to 19)
Configurations:
P = meter in control on line P
A = control from chamber A of the actuator
B = control from chamber B of the actuator
D = control from chambers A and B of the actuator
T = meter out control on line T
PCT3 = meter in control on line P with backpressure
adjustable on line T up to 70 bar
(A and B configurations are not available in K version)
Flow adjustment range:
1 = 1 l/min 16 = 16 l/min
4 = 4 l/min 22 = 22 l/min
10 = 10 l/min 30 = 30 l/min
K = only ISO 4401-03 modular block
supplied without flow control valve
Modular version
size ISO 4401-03
Pressure and temperature
compensated flow control valve
C
P
R
1 - / M / - / 10
/
3 - HYDRAULIC FLUIDS
Use mineral oil-based hydraulic fluids HL or HM type, according to ISO 6743-4. For these fluids, use NBR seals. For fluids HFDR type
(phosphate esters) use FPM seals (code V). For the use of other kinds of fluid such as HFA, HFB, HFC, please consult our technical
department.
Using fluids at temperatures higher than 80 °C causes a faster degradation of the fluid and of the seals characteristics. The fluid must be
preserved in its physical and chemical characteristics.