65 360/121 ED
1/2
65 360/121 ED
50.8
37.3
27
3.2
16.7
54
M6
facoltativo
Attacco "T"
B
A
P
T
Ø11.2 (max)
46
32.5
21.4
6.3
CHM5
PILOT OPERATED CHECK VALVE
SERIES 11
OPERATING PRINCIPLEMOUNTING INTERFACE
This is a pilot operated check valve (spring closing and
cone on edge seals) with a built-in flow control feature.
The mounting surface is according to the ISO 4401
standard.
The CHM5 are always mounted under the ISO 4401-05
directional solenoid valves and can be assembled with all
other ISO 4401-05 valves.
— The pre-opening feature of the valve causes the
decompression of the cylinder chamber, leading to a
smooth motion.
ISO 4401-05-04-0-05
(CETOP 4.2-4-05-350)
HYDRAULIC SYMBOLS
optional
“T” port
MODULAR VERSION
ISO 4401-05
p max
350 bar
Q max 120 l/min
Maximum operating pressure bar 350
Maximum flow rate l/min 120
Decompression ratio 14,9:1
Piloting ratio 2,3:1
Check valve cracking pressure bar 2
Ambient temperature range °C -20 / +60
Fluid temperature range °C -20 / +80
Fluid viscosity range cSt 10 ÷ 400
Recommended viscosity cSt 25
Fluid contamination degree
According to ISO 4406:1999 class 20/18/15
Mass: CHM5-D
CHM5-SA and CHM5-SB
kg
2,2
1,9
PERFORMANCES
(measured with mineral oil of viscosity 36 cSt at 50°C)
65 360/121 ED
2/2
CHM5
SERIES 10
REPRODUCTION IS FORBIDDEN. THE COMPANY RESERVES THE RIGHT TO APPLY ANY MODIFICATIONS.
2 - CHARACTERISTIC CURVES (obtained with viscosity of 36 cSt at 50°C)
4 - OVERALL AND MOUNTING DIMENSIONS
1 - IDENTIFICATION CODE
3 - HYDRAULIC FLUIDS
Use mineral oil-based hydraulic fluids HL or HM type,
according to ISO 6743-4. For these fluids, use NBR
seals (code N). For fluids HFDR type (phosphate esters)
use FPM seals (code V).
For the use of other kinds of fluid such as HFA, HFB,
HFC, please consult our technical department.
Using fluids at temperatures higher than 80 °C causes a
faster degradation of the fluid and of the seals
characteristics. The fluid must be preserved in its
physical and chemical characteristics.
Series No. (the overall and mounting dimensions
remain unchanged from 10 to 19)
Configurations: D   = seal on both A and B lines
SA = seal on line B of the actuator
SB = seal on line B of the actuator
Modular version
Pilot operated check
valve
ISO 4401-05 size
C H M 5 - / 11
1 Mounting surface with sealing rings:
5 OR type 2050 (12.42x1.78) -90Shore
Seals:
N = NBR seals for mineral oil (standard)
V = FPM seals for special fluids
PRESSUREDROPS Δp (Q)
dimensions in mm