65 250/110 ED
1/2
65 250/110 ED
0.75
T
B
31.75
P
A
25.9
15.5
5.1
12.7
31
M5
Ø4
Ø7.5 (max)Ø7.5
(max)
21.5
30.2
40.5
33
MVPP
PILOT OPERATED
CHECK VALVE
SERIES 50
HYDRAULIC SYMBOLS
OPERATING PRINCIPLEMOUNTING INTERFACE
This is a check valve (spring closing and cone on edge
seals) with a built-in flow control feature. The mounting
surface is according to the ISO 4401 (CETOP RP 121H)
standards
Its use allows:
- prevention of flow one-way;
- flow in one-way, if opened by a pilot pressure;
- free flow in the other way.
The MVPP are always mounted under the ISO 4401-03
(CETOP 03) directional solenoid valves and can be
assembled with all other ISO 4401-03 (CETOP 03) valves.
CONFIGURATIONS (see hydraulic symbols table)
Configurations “SA” - “SB”: are used to lock the actuator in one direction.
Configuration “D”: is used to lock the position of the actuator in both directions.
PERFORMANCES (measured with mineral oil of viscosity 36cSt at 50°C)
Maximum operating pressure
Check valve cracking pressure
bar
350
3
Maximum flow rate in controlled lines
Maximum flow rate in the free lines
l/min
50
75
Ratio between the pressure in the locked
chambers and the piloting pressure
3,4:1
Ambient temperature range °C -20 / +50
Fluid temperature range °C -20 / +80
Fluid viscosity range cSt 10 ÷ 400
Fluid contamination degree
According to ISO 4406:1999
class 20/18/15
Recommended viscosity cSt 25
Mass: kg 1,3
MODULAR VERSION
ISO 4401-03 (CETOP 03)
p max
350 bar
Q max (see table of performances)
ISO 4401-03-02-0-05
(CETOP 4.2-4-03-350)
65 250/110 ED
2/2
DUPLOMATIC OLEODINAMICA S.p.A.
20015 PARABIAGO (MI)  Via M. Re Depaolini 24
Tel. +39 0331.895.111
Fax +39 0331.895.339
www.duplomatic.com  e-mail: sales.exp@duplomatic.com
MVPP
SERIES 50
REPRODUCTION IS FORBIDDEN. THE COMPANY RESERVES THE RIGHT TO APPLY ANY MODIFICATIONS.
40
48
1
18.77.5
T
BA
P
96
80.5
46
2 - CHARACTERISTIC CURVES (values obtained with viscosity of 36 cSt at 50°C)
4 - OVERALL AND MOUNTING DIMENSIONS
1 - IDENTIFICATION CODE
Seals: omit for mineral oils
V = viton for special fluids
Series No. (the overall and mounting
dimensions remain unchanged from 50 to 59)
Configurations:
SA = seal on line A of the actuator
SB = seal on line B of the actuator
D = seal on lines A and B of the actuator
ISO 4401-03 (CETOP 03) size
Modular version
Pilot operated check valve
dimensions in mm
V
M
P P - / 50 /
only for MVPP-SB
only for MVPP-SA
3 - HYDRAULIC FLUIDS
Use mineral oil-based hydraulic fluids HL or HM type, according to ISO 6743-4. For these fluids, use NBR seals. For fluids HFDR type
(phosphate esters) use FPM seals (code V). For the use of other kinds of fluid such as HFA, HFB, HFC, please consult our technical
department. Using fluids at temperatures higher than 80 °C causes a faster degradation of the fluid and of the seals characteristics.
The fluid must be preserved in its physical and chemical characteristics.
Mounting surface with sealing rings:
4 OR type 2037 (9.25x1.78) - 90 Sh
1