65 200/111 ED
1/2
65 200/111 ED
0.75
30.2
40.5
21.5
5.1
12.7
31.75
BA
T
P
M5
15.5
25.9
31
Ø7.5 (max)
MVR
DIRECT CHECK VALVE
SERIES 51
HYDRAULIC SYMBOLS
OPERATING PRINCIPLEMOUNTING INTERFACE
The MVR valve is a direct check valve made as a modular
version with mounting surface according to the ISO 4401
(CETOP RP 121H) standards.
It is used to avoid oil backflows and self-emptying of lines,
or to generate back-pressures.
— It can be assembled quickly under the ISO 4401-03
(CETOP 03) directional solenoid valves without the use of
pipes, using suitable tie-rods or bolts.
It is available in versions with the check valve only on single
line (P, T, A or B) or on both lines (P and T or A and B).
ISO 4401-03-02-0-05
(CETOP 4.2-4-03-350)
CONFIGURATIONS (see Hydraulic symbols table)
MVR-SP: check valve on line P.
— MVR-SA: check valve on line A..
MVR-ST: check valve on line T.
— MVR-SB: check valve on line B.
MVR-SPT: check valve on lines P and T.
MVR-D: check valve on lines A and B.
MODULAR VERSION
ISO 4401-03 (CETOP 03)
p max
350 bar
Q max (see table of performances)
PERFORMANCES (measured with mineral oil of viscosity 36cSt at 50°C)
Maximum operating pressure
Check valve cracking pressure
bar
350
3 - 0,5 - 5
Maximum flow rate in controlled lines
Maximum flow rate in the free lines
l/min
50
75
Ambient temperature range °C -20 / +50
Fluid temperature range °C -20 / +80
Fluid viscosity range cSt 10 ÷ 400
Fluid contamination degree
According to ISO 4406:1999
class 20/18/15
Recommended viscosity cSt 25
Mass: kg 1
65 200/111 ED
2/2
DUPLOMATIC OLEODINAMICA S.p.A.
20015 PARABIAGO (MI)  Via M. Re Depaolini 24
Tel. +39 0331.895.111
Fax +39 0331.895.339
www.duplomatic.com  e-mail: sales.exp@duplomatic.com
MVR
SERIES 51
REPRODUCTION IS FORBIDDEN. THE COMPANY RESERVES THE RIGHT TO APPLY ANY MODIFICATIONS.
1 - IDENTIFICATION CODE
40
48
1
11.2
T
P
AB
7.5
46
65
Seals: omit for mineral oils
V = viton for special fluids
Series No. (the overall and mounting
dimensions remain unchanged from 50 to 59)
SP: check valve on line P
SA: check valve on line A
SB: check valve on line B
ST: check valve on line T
SPT: check valve on lines P and T
D : check valve on lines A and B
2 - CHARACTERISTIC CURVES (values obtained with viscosity of 36 cSt at 50°C)
4 - OVERALL AND MOUNTING DIMENSIONS
Mounting surface with sealing rings:
4 OR type 2037 (9.25x1.78) - 90 Sh
1
Size: ISO 4401-03
(CETOP 03). Modular version.
Check valve
Cracking pressure:
omit for standard cracking pressure = 3 bar
1 = 0,5 bar
3 = 5 bar
dimensions in mm
1) pressure drops on controlled lines
2) pressure drops on free lines
NOTE: check valve cracking pressure
must be added to the values indicated
in the curve 1 in the diagram
V
M
R - / 51 /
3 - HYDRAULIC FLUIDS
Use mineral oil-based hydraulic fluids HL or HM type, according to ISO 6743-4. For these fluids, use NBR seals. For fluids HFDR type
(phosphate esters) use FPM seals (code V). For the use of other kinds of fluid such as HFA, HFB, HFC, please consult our technical
department. Using fluids at temperatures higher than 80 °C causes a faster degradation of the fluid and of the seals characteristics.
The fluid must be preserved in its physical and chemical characteristics.