64 310/119 ED
2/2
QTM5
SERIES 10
REPRODUCTION IS FORBIDDEN. THE COMPANY RESERVES THE RIGHT TO APPLY ANY MODIFICATIONS.
2 - CHARACTERISTIC CURVES (values obtained with viscosity of 36 cSt at 50°C)
4 - OVERALL AND MOUNTING DIMENSIONS
1 - IDENTIFICATION CODE
controlled flow
versus Δp
with different
restrictor
opening values
CONTROLLED FLOW Δp - Q PRESSURE DROPS Δp - Q
dimensions in mm
1) pressure drops through
the check valve with
restrictor all closed
2) pressure drops through
the free ports
Seals:
N = Seals in NBR for mineral oils (standard)
V = Seals in FPM for special fluids
Series No.
(the overall and mounting dimensions remain
unchanged from 10 to 19)
Modular version
Flow restrictor valve
ISO 4401-05 size
S = adjustment screw (standard)
K1 = adjustment knob
Q T M 5 - / 10 /
3 - HYDRAULIC FLUIDS
Use mineral oil-based hydraulic fluids HL or HM type, according to ISO 6743-4. For these fluids, use NBR seals (code N). For fluids HFDR type
(phosphate esters) use FPM seals (code V). For the use of other kinds of fluid such as HFA, HFB, HFC, please consult our technical
department. Using fluids at temperatures higher than 80 °C causes a faster degradation of the fluid and of the seals characteristics.
The fluid must be preserved in its physical and chemical characteristics.
1 Mounting surface with sealing rings:
5 OR type 2050 (12.42x1.78) - 90 Shore
2 Socket hex adjustment screw:
spanner 5 (standard)
Rotate anticlockwise to increase flow
3 Locking nut: spanner 17
4 Adjustment knob K1 (option)
Rotate anticlockwise to increase the flow
Versions for meter-out:
D = control on lines A and B
SA = control on line A
SB = control on line B
Versions for meter-in:
RD = control on lines A and B
RSA = control on line A
RSB = control on line B
screw turns to close