64 201/223 ED
1/4
64 201/223 ED
0.75
0.75
T
B
31.75
31.75
P
A
25.9
25.9
15.5
15.5
5.1
5.1
12.7
12.7
31
31
M5
M5
Ø4
Ø4
Ø7.5 (max)
Ø7.5 (max)
21.5
21.5
30.2
30.2
40.5
40.5
33
33
QTM3
FLOW RESTRICTOR VALVE
SERIES 10
HYDRAULIC SYMBOLS
OPERATING PRINCIPLEMOUNTING INTERFACE
— This is a non-compensated flow control valve with a check
valve for reverse free flow. It is made in modular version
and with mounting surface according to the ISO 4401
standards; it can be assembled quickly without the use of
pipes, but using only suitable tie-rods or bolts, thus forming
compact modular groups.
— It is also available as a reversible valve (G* versions). The
control takes place as meter-in or meter-out, depending on
the way in which the valve is facing the OR subplate.
— The built-in check valve allows the reverse free flow
(cracking pressure of 0.5 bar).
— It can be supplied with adjustment by hexagonal socket
screw or by knob.
MODULAR VERSION
ISO 4401-03
p max
350 bar
Q  max (see table of performances)
PERFORMANCES (measured with mineral oil of viscosity 36 cSt at 50°C)
Maximum operating pressure
Check valve cracking pressure
bar
350
0.5
Maximum flow rate in the controlled lines
Maximum flow rate in the free lines
Min. controlled flowrate with Δp 10 bar
l/min
50
75
≤0.060
Ambient temperature range
°C -20 / +60
Fluid temperature range
°C -20 / +80
Fluid viscosity range
cSt 10 ÷ 400
Fluid contamination degree
According to ISO 4406:1999
class 20/18/15
Recommended viscosity
cSt 25
Mass
kg 1.3
ISO 4401-03-02-0-05
(CETOP 4.2-4-03-350)
QTM3-D
QTM3-GD
QTM3-RD
QTM3-SA
QTM3-GSA
QTM3-SB
QTM3-GSB
64 201/223 ED
2/4
QTM3
SERIES 10
2 - CHARACTERISTIC CURVES
(values obtained with viscosity of 36 cSt at 50°C)
1 - IDENTIFICATION CODE
Series No.
(the overall and mounting dimensions
remain unchanged from 10 to 19)
Configurations:
D: meter-out control in lines A and B (standard)
RD: meter-in control in lines A and B
SA: meter-out control in line A
SB: meter-out control in line B
Configurations G* - reversible valve (NOTE 1)
GD: control in lines A and B
GSA: control in line A
GSB: control in line B
ISO 4401-03 size
Flow restrictor valve
with check valve
for reverse free flow
Adjustment type:
S = with hexagonal socket screw (standard)
CK3 = with push, adjust, lock knob
(see point 6)
ADJUSTMENT
PRESSURE DROPS Δp - Q
Q T M 3 - / 10 /
KNOB TURNS
only for QTM3-*B
only for QTM3-*A
3 - HYDRAULIC FLUIDS
Use mineral oil-based hydraulic fluids HL or HM type, according to ISO 6743-4. For these fluids, use NBR seals. For fluids HFDR type
(phosphate esters) use FPM seals (code V). For the use of other kinds of fluid such as HFA, HFB, HFC, please consult our technical
department.
Using fluids at temperatures higher than 80 °C causes a faster degradation of the fluid and of the seals characteristics.The fluid must be
preserved in its physical and chemical characteristics.
NOTE 1: The valve body does not provide the OR seats. The mounting interface is achieved by interposition of an OR subplate (included
in the delivery). The control of flow (meter-in or meter-out) is depending on the way of assembly the valve on the subplate.
NOTE 2: The standard valve is supplied with surface treatment of phosphating black.
The zinc-nickel finishing on the valve body makes the valve suitable to ensure a salt spray resistance up to 240 hours.
(test operated according to UNI EN ISO 9227 standards and test evaluation operated according to UNI EN ISO 10289 standards).
Modular version
Seals:
N = NBR seals for mineral oil (standard)
V = FPM seals for special fluids
Option:
/ W 7 = Zinc-nickel surface
treatment (see NOTE 2)
Omit if not required
64 201/223 ED
3/4
QTM3
SERIES 10
4 - QTM3 -D, -RD AND -S* - OVERALL AND MOUNTING DIMENSIONS
dimensions in mm
QTM3-D
QTM3-RD
QTM3-SB
adjustment screw on QTM3-SA
1 Mounting surface with sealing rings:
N. 4 OR type 2037 (9.25x1.78)
90 Shore
2 Socket hex adjustment screw:
Hex key 6
Rotate anticlockwise to increase flow
64 201/223 ED
4/4
QTM3
SERIES 10
REPRODUCTION IS FORBIDDEN. THE COMPANY RESERVES THE RIGHT TO APPLY ANY MODIFICATIONS.
5 - QTM3-G* - OVERALL AND MOUNTING DIMENSIONS
dimensions in mm
1
OR subplate code 1955131
(included in the supply):
N. 4 KANTSEAL DKAR00012
(70 Shore)
2
Socket hex adjustment screw:
Hex key 6
Rotate anticlockwise to increase flow
3
Identification plate
QTM3-GD
QTM3-GSB
adjustment screw on QTM3-GSA
meter-in
control
meter-out
control
3
6 - ADJUSTMENT KNOB
Valves can be supplied with adjustment knob, which is engaged by pushing and twisting at
the same time. When released, the knob disengages to secure the adjustment from
involuntary tampering.
Add CK3 in the identification code to order this version (see point 1).