64 201/223 ED
2/4
QTM3
SERIES 10
2 - CHARACTERISTIC CURVES
(values obtained with viscosity of 36 cSt at 50°C)
1 - IDENTIFICATION CODE
Series No.
(the overall and mounting dimensions
remain unchanged from 10 to 19)
Configurations:
D: meter-out control in lines A and B (standard)
RD: meter-in control in lines A and B
SA: meter-out control in line A
SB: meter-out control in line B
Configurations G* - reversible valve (NOTE 1)
GD: control in lines A and B
GSA: control in line A
GSB: control in line B
ISO 4401-03 size
Flow restrictor valve
with check valve
for reverse free flow
Adjustment type:
S = with hexagonal socket screw (standard)
CK3 = with push, adjust, lock knob
(see point 6)
ADJUSTMENT
PRESSURE DROPS Δp - Q
Q T M 3 - / 10 /
KNOB TURNS
only for QTM3-*B
only for QTM3-*A
3 - HYDRAULIC FLUIDS
Use mineral oil-based hydraulic fluids HL or HM type, according to ISO 6743-4. For these fluids, use NBR seals. For fluids HFDR type
(phosphate esters) use FPM seals (code V). For the use of other kinds of fluid such as HFA, HFB, HFC, please consult our technical
department.
Using fluids at temperatures higher than 80 °C causes a faster degradation of the fluid and of the seals characteristics.The fluid must be
preserved in its physical and chemical characteristics.
NOTE 1: The valve body does not provide the OR seats. The mounting interface is achieved by interposition of an OR subplate (included
in the delivery). The control of flow (meter-in or meter-out) is depending on the way of assembly the valve on the subplate.
NOTE 2: The standard valve is supplied with surface treatment of phosphating black.
The zinc-nickel finishing on the valve body makes the valve suitable to ensure a salt spray resistance up to 240 hours.
(test operated according to UNI EN ISO 9227 standards and test evaluation operated according to UNI EN ISO 10289 standards).
Modular version
Seals:
N = NBR seals for mineral oil (standard)
V = FPM seals for special fluids
Option:
/ W 7 = Zinc-nickel surface
treatment (see NOTE 2)
Omit if not required