64 411/121 ED
2/2
QTM7
SERIES 20
REPRODUCTION IS FORBIDDEN. THE COMPANY RESERVES THE RIGHT TO APPLY ANY MODIFICATIONS.
2 - CHARACTERISTIC CURVES
(values obtained with viscosity of 36 cSt at 50°C)
1 - IDENTIFICATION CODE
controlled flow
versus Δp
with different
restrictor
opening values
CONTROLLED FLOW
adjustment screw turns
PRESSURE DROPS Δp - Q
dimensions in mm
1) pressure drops through the
check valve with closed
restrictor
2) pressure drops through the
free ports
Seals:
N = Seals in NBR for mineral oils (standard)
V = Seals in FPM for special fluids
Series No. (the overall and mounting
dimensions remain unchanged from 20 to 29)
SA = meter-out control on line A
D = meter-out control on lines A and B
Modular version
Throttle check valve
ISO 4401-07 size
Adjustment screw
Q T M 7 - / 20 / S
3 - HYDRAULIC FLUIDS
Use mineral oil-based hydraulic fluids HL or HM type, according to ISO 6743-4. For these fluids, use NBR seals (code N). For fluids HFDR type
(phosphate esters) use FPM seals (code V). For the use of other kinds of fluid such as HFA, HFB, HFC, please consult our technical
department. Using fluids at temperatures higher than 80 °C causes a faster degradation of the fluid and of the seals characteristics. The fluid
must be preserved in its physical and chemical characteristics.
4 - OVERALL AND MOUNTING DIMENSIONS
1
Mounting surface with sealing rings:
4 OR type 130 (22.22x2.62)
2 OR type 2043 (10.82x1.78)
2
Socket hex adjustment screw: Allen key 8
Rotate anticlockwise to increase the flow
3 Locking nut: spanner 24