62 310/122 ED
2/2
PZM5
SERIES 10
REPRODUCTION IS FORBIDDEN. THE COMPANY RESERVES THE RIGHT TO APPLY ANY MODIFICATIONS.
1 - IDENTIFICATION CODE
2 - CHARACTERISTIC CURVES
(values obtained with viscosity of 36 cSt at 50 °C)
1) pressure drops
P
1
→P
2) pressure drops
on free lines
(ex. A→A
1
)
dimensions in mm
ADJUSTMENT PRESSURE DROPS Δp - Q
3 - HYDRAULIC FLUIDS
Use mineral oil-based hydraulic fluids HL or HM type, according to ISO 6743-4. For these fluids, use NBR seals. For fluids HFDR type
(phosphate esters) use FPM seals (code V). For the use of other kinds of fluid such as HFA, HFB, HFC, please consult our technical
department. Using fluids at temperatures higher than 80 °C causes a faster degradation of the fluid and of the seals characteristics. The fluid
must be preserved in its physical and chemical characteristics.
4 - OVERALL AND MOUNTING DIMENSIONS
1 Locking nut
spanner 19
2 Socket hex
adjustment screw:
Allen key 6.
Rotate clockwise to
increase pressure
3 Mounting surface
with sealing rings:
5 OR type 2050
(12.42x1.78)
90 Shore
4 Pressure gauge port
1/4” BSP
5 Adjustment knob K
Versions:
P = pressure reduction in P. Internal drain to line T
B
PA = pressure reduction in line P-A when line B is connected to the
tank; full pressure in line P-B
PB = pressure reduction in line P-B when line A is connected to the
tank; full pressure in line P-A.
Series No. (the overall and mounting dimensions
remain unchanged from 10 to 19)
Option: K = Adjustment knob.
(Omit for adjustment with hex socket
screw)
Pressure adjustment range:
070 = 8 ÷ 70 bar 150 = 8 ÷ 150 bar 280 = 8 ÷ 280 bar
Pressure reducing valve, pilot operated
Modular version
Size ISO 4401-05
Z M 5 - / /10P
Seals:
N = NBR seals for mineral oils (standard)
V = FPM seals for special fluids