62 200/117 ED
1/6
P1
P
62 200/117 ED
0.750.75
TT
BB
31.7531.75
PP
AA
25.925.9
15.515.5
5.15.1
12.712.7
3131
M5M5
Ø4Ø4
Ø7.5(max)Ø7.5(max)
21.521.5
30.230.2
40.540.5
3333
PP
P1P1
MZD
DIRECT OPERATED THREE-WAY
PRESSURE REDUCING VALVE
WITH FIXED OR VARIABLE
ADJUSTMENT
OPERATING PRINCIPLEMOUNTING INTERFACE
— The MZD valve is a three-way spool type direct operated
pressure reducing valve. It is normally open in the rest
position and the hydraulic fluid passes freely from the P1 line
to the P line.
The spool is subjected to the line P pressure on one side,
and on the other side by the adjustment spring. When the
pressure in line P exceeds the value set by the spring, the
valve closes until the pressure in P (reduced) equals the
calibrated value.
— The valve construction provides good adjustment sensitivity
with reduced drainage flow. The drainage is connected to
line T inside the valve.
— The three-way design provides protection of the secondary
circuit from pressure surges since it allows a reverse flow
from the actuator to the T discharge line.
— It is made as a modular version with ports
according to the ISO 4401 standards and can be
assembled quickly, without use of pipes, under
the ISO 4401-03 solenoid valves.
— The variable adjustment version is supplied
with a hexagonal head adjustment screw. Upon
request, it can be equipped with a SICBLOC
adjustment knob.
— The fixed adjustment version is available set
at value 20, 25 or 30 bar pressure.
I
SO 4401-03-02-0-05
(CETOP 4.2-4-03-350)
MODULAR VERSION
ISO 4401-03
p max
350 bar
Q max (see table of performances)
Maximum operating pressure
Maximum pressure on port T
bar
350
10
Maximum flow rate in the controlled lines
Maximum flow rate in the free lines
Drainage flow rate
l/min
50
75
≤ 0,08
Ambient temperature range °C -20 / +60
Fluid temperature range °C -20 / +80
Fluid viscosity range cSt 10 ÷ 400
Fluid contamination degree
According to ISO 4406:1999
class 20/18/15
Recommended viscosity cSt 25
Mass kg 1,4
PERFORMANCES (measured with mineral oil of viscosity 36cSt at 50°C)
CONFIGURATIONS (see hydraulic symbols at par.1)
— MZD*: pressure reduction on line P, drainage connected with
line T.
— MZD*/A and MZD*/RA: pressure reduction on line A toward the
actuator and maximum pressure in line B, drainage connected
with line T.
— MZD*/B and MZD*/RB: pressure reduction on line B toward the
actuator and maximum pressure in line A, drainage connected
with line T.