61 310/314 ED
2/2
DUPLOMATIC OLEODINAMICA S.p.A.
20015 PARABIAGO (MI) Via M. Re Depaolini 24
Tel. +39 0331.895.111
Fax +39 0331.895.339
www.duplomatic.com e-mail: sales.exp@duplomatic.com
PRM5
SERIES 10
REPRODUCTION IS FORBIDDEN. THE COMPANY RESERVES THE RIGHT TO APPLY ANY MODIFICATIONS.
2 - CHARACTERISTIC CURVES (
values obtained with viscosity of 36 cSt at 50°C)
dimensions in mm
, PRM5-D
1) pressure drop on
controlled lines PT,
AT, BT, DT
2) pressure drop on
free lines
1 - IDENTIFICATION CODE
A
DJUSTMENT
P
RESSURE DROPS ∆p - Q
3 - HYDRAULIC FLUIDS
Use mineral oil-based hydraulic fluids HL or HM type, according to ISO 6743-4. For these fluids, use NBR seals (code N). For fluids HFDR type
(phosphate esters) use FPM seals (code V). For the use of other kinds of fluid such as HFA, HFB, HFC, please consult our technical
department. Using fluids at temperatures higher than 80 °C causes a faster degradation of the fluid and of the seals characteristics. The fluid
must be preserved in its physical and chemical characteristics.
4 - OVERALL AND MOUNTING DIMENSIONS
1 Socket hex adjustment
screw: Hex key 4.
Rotate clockwise to increase
pressure
2 Locking nut: spanner 13
3 Mounting surface with
sealing rings:
5 OR type 2050
(12.42 x 1.78) 90 Shore
Seals:
N = NBR seals for mineral oils (standard)
V = FPM seals for special fluids
Series No. (the overall and mounting dimensions
remain unchanged from 10 to 19)
Versions:
PT: single on line P with discharge in TA
AT: single on line A with discharge in TA
BT: single on line B with discharge in TA and TB
DT: double on lines A-B with discharge in TA and TB
D: double on lines A-B with cross discharge
Pressure adjustment range:
070 = 6 ÷ 70 bar (17 bar / turn)
140 = 6 ÷ 140 bar (32 bar / turn)
210 = 6 ÷ 210 bar (47 bar / turn)
350 = 6 ÷ 350 bar (78 bar / turn)
ISO 4401-05 (CETOP 05) size
Modular version
Pilot operated pressure
relief valve
P R M 5 - / 10 /
Option:
K = Adjustment knob. Omit for adjustment with hex
socket screw (standard)
Option: W7 surface treatment.
Omit if not required (NOTE)
NOTE: Upon request we can supply these valves
completely with zinc-nickel surface treatment on the body.
Add the suffix /W7 at the end of the identification code.
K VERSION