MCD
DIRECT OPERATED
PRESSURE RELIEF VALVE
SERIES 51
PERFORMANCES (measured with mineral oil of viscosity 36cSt at 50°C)
HYDRAULIC SYMBOLS
OPERATING PRINCIPLEMOUNTING INTERFACE
— The MCD valve is a direct operated pressure relief valve made
as a modular version with mounting surface according to the
ISO 4401 (CETOP RP 121H) standards.
— It can be assembled with all ISO 4401-03 (CETOP 03) modular
valves without use of pipes, using suitable tie-rods or bolts.
— It is available in versions for single adjustment on one control
line, or dual on two control lines and with four different pressure
adjustment ranges.
— This valve is normally used as a hydraulic circuit pressure
limiting device or as a limiting device of the pressure peaks
generated during the movement of hydraulic actuators.
— It is normally supplied with a hexagonal head adjustment
screw, locking nut and limitation of the maximum adjustment
travel.
ISO 4401-03-02-0-05
(CETOP 4.2-4-03-350)
CONFIGURATIONS (see Hydraulic symbols table)
— “SP”: controls the pressure on line P with discharge in T.
— “SAT”: controls the pressure on line A with discharge in T.
— “SBT”: controls the pressure on line B with discharge in T.
— “DT”: controls the pressure on lines A-B with discharge in T.
— “D”: controls the pressure on lines A-B with crossed discharges
— “SB”: controls the pressure on line B with discharge in A.
MODULAR VERSION
ISO 4401-03 (CETOP 03)
p max
350 bar
Q max (see table of performances)
Maximum operating pressure bar 350
Minimum controlled pressure see ∆p diagram.
Maximum flow rate in controlled lines
Maximum flow rate in the free lines
l/min
50
75
Ambient temperature range °C -20 / +50
Fluid temperature range °C -20 / +80
Fluid viscosity range cSt 10 ÷ 400
Fluid contamination degree
According to ISO 4406:1999
class 20/18/15
Recommended viscosity cSt 25
Mass: MCD-SP / MCD-SAT / MCD-SBT /
MCD-SB
MCD-DT / MCD-D
kg 1,4
2,0