48 900/122 ED
3/22
LC
*
Max operating pressure LC cartridge valve bar 420
Max operating pressure limit of covers
type DP*, DPE*, DF1, DF2, LCM
bar 350
Max operating pressure with distributor installed on cover See technical characteristics of the distributor
Ambient temperature range °C -20 / +50
Fluid temperature range °C -20 / +80
Fluid viscosity range cSt 10 ÷ 400
Fluid contamination degree According to ISO 4406:1999 class 20/18/15
Recommended viscosity cSt 25
NOMINAL SIZE
16 25 32 40 50 63
Area A1 cm
2
1,54 3 6 8,76 14,8 24,6
Area A2 cm
2
1 2 4 5,76 9,7 16,1
Area A3 cm
2
2,54 4,9 10 14,3 24,3 40,7
Version S:
opening stroke h cm 0,8 1 1,25 1,6 1,8 2,3
opening volume cm
3
2,03 4,9 12,5 22,88 43,74 96,26
max recommended flow l/min 250 500 900 1300 2000 3000
Version D:
opening stroke h cm
0,8 1,15 1,5 1,8 2,2 2,7
opening volume cm
3
2,03 5,63 15 25,74 53,46 110
max recommended flow l/min 200 450 800 1100 1700 2700
Cracking
pressure
A→B
spring 0,5
bar
0,5 0,5 0,5 0,5 0,5 -
spring 2 2 2 2 2 2 2
spring 4 4 4 4 4 4 -
B→A
spring 0,5 0,9 1,1 0,7 0,76 0,8 -
spring 2 3,1 3 3,1 3 3,2 3,2
spring 4 6,15 5,9 5,4 5,9 5,9 -
Mass Kg 0,25 0,5 1,1 1,9 3,9 7,8
NOMINAL SIZE
16 25 32 40 50 63
Area A1 = Area A3 cm
2
2,54 4,9 10 14,4 24,3 40,7
Version S: max recommended flow l/min 200 400 900 1000 1500 2500
Cracking
pressure
spring 1
bar
- - - - - 1
spring 2 2 2 2 2 2 -
Mass Kg 0,25 0,5 1,1 1,9 3,9 7,8
3 - TECHNICAL CHARACTERISTICS
(cartridge valve with control cover)
3.1 - Cartridge valves type Q performances
(flow control function)
3.2 - Cartridge valves type P performances
(pressure control function)