44 101/120 ED
1/28
44 101/120 ED
BDL, BDM and BDS are stacked valve assemblies, very
well-rounded thanks to their modular design.
Elements have been designed to be assembled in parallel
connection, mounting up to 10 stackable valves. The same
elements allow to create series circuits by inserting plugs in
order to divert the oil path.
Elements specifically designed for BD*2 series circuits
complete the BD* range.
— BD* assemblies are suitable for compact applications in the
mobile and in mini-power pack industries.
Directional valve elements are available in two thicknesses,
with working ports 3/8” BSP, 1/2” BSP, SAE06 and
SAE–08 threaded.
BD*
STACKABLE
DIRECTIONAL CONTROL VALVE
SERIES 10
HYDRAULIC SYMBOL
OPERATING PRINCIPLE
p max (see table of performances)
Q max (see table of performances)
BDL BDM BDS
Maximum operating pressure:
- P-A-B ports
- T / T1 ports
bar
280
280
320
250
320
250
Maximum flowrate:
- parallel
- series
l/min
40
40
50
40
60
50
Pressure drops ∆p - Q see paragraph 3
Electrical characteristics see paragraph 6
Operating limits see paragraph 4
Electrical connections see paragraph 7
Ambient temperature range °C -20 / +50
Fluid temperature range °C -20 / +80
Fluid viscosity range cSt 10 ÷ 400
Fluid contamination degree According to ISO 4406:1999 class 20/18/15
Recommended viscosity cSt 25
Mass (BDS3-B38-S) kg 1,57 1,73 2,1
Surface treatment of inlet and outlet
elements and valves bodies
zinc-nickel
PERFORMANCES
(obtained with mineral oil with viscosity of 36 cSt at 50°C)
44 101/120 ED
2/28
BD*
SERIES 10
1 - IDENTIFICATION CODES OF SEPARATE ELEMENTS
Here below are shown the identification codes for the separate elements of the stackable valve. Parallel circuits can be assembled with these
elements. The same elements allow to create series circuits by inserting plugs in order to divert the oil path.
1.1 - Directional valve element
NOTE: A galvanic surface treatment zinc-nickel is applied to body elements and plates, so BDS valves with WK* type coils and the BDL
type valves suitable to withstand a salt spray exposure time of 600 hours. BDS valves with K* type coils and BDM valves are suitable to
withstand a salt spray exposure time of 240 hours (test carried out according to the UNI EN ISO 9227 and assessment test carried out
according to UNI EN ISO 10289).
Seals:
N = NBR seals for mineral oil (standard)
V = FPM seals for special fluids
Series no.
(the overall and mounting dimensions
remain unchanged from 10 to 19)
Size :
2 = thickness 38 mm
3 = thickness 46 mm
Solenoid tube (mm):
L= 14
M= 19
S= 22 (only size 3)
Ports:
B38 = 3/8” BSP
B12 = 1/2” BSP (only for size 3)
S06 = 9/16” 18 UNF (SAE 06)
S08 = 3/4” 16 UNF (SAE 08) (only for size 3)
NOTE: Variants are available. See paragraph 10.1
Spool type
(see point 1.2)
Stack directional valve
element, on-off
BD - - / 10 /-
Coil type:
DC coils
D12 = 12 V
D24 = 24 V
D28 = 28 V
D48 = 48 V
D00 = valve without coil supplied with locking ring
Coil electrical connection:
See below for availability, see par. 6 and 7 for
details
K1 = plug for connector type EN 175301-803
(ex DIN 43650) (standard)
K7, WK7, WK7D = plug DEUTSCH DT04-2P for
male connector type DEUTSCH DT06-2S
The electrical connection K2 (AMP JUNIOR type) is
available upon request
Manual override (see par. 10.6 - 10.8):
for BDL:
omit for manual override boot protected
integrated in the coil locking ring (standard)
for BDM and BDS:
omit for pin manual override integrated in
the tube (standard).
CM = manual override boot protected
for BDL, BDM and BDS
CK1 = turning knob override
CHL = light duty hand lever. p max 50 bar in
T line (not available for series circuits)
BDL
K1 K2 WK7
D12
D24
D28 - -
D48 - -
BDM
K1 K2 K7
- - -
- - -
BDS
K1 K2 K7 | WK1 WK7 WK7D
- - - - -
- - - - -
Available coils
The letter ‘W’ identifies coils with an high IP degree. This IP degree is reached by specific surface
treatments and / or design adaptations.
■ available
□ upon request
44 101/120 ED
3/28
BD*
SERIES 10
1.2 - Available spools
Type S:
2 solenoids - 3 positions
spring centreing
Type SA*: 1 solenoid side A
2 positions (central + external)
spring centreing
Type SB*: 1 solenoid side B
2 positions (central + external)
spring centreing
Type TA*:
1 solenoid side A
2 external positions
with return spring
Type TB*:
1 solenoid side B
2 external positions
with return spring
NOTE 1: BDS valves use spools of DS3 solenoid valve. Please refer to catalogue 41150 for others spools.
NOTE 2: Further spools for BDL and BDM are upon request. Please contact our technical department.
44 101/120 ED
4/28
BD*
SERIES 10
Nominal size
Seals:
N = NBR seals for mineral oil (standard)
V = FPM seals for special fluids
Series no.:
(the overall and mounting dimensions remain
unchanged from 10 to 19)
Material:
S = Steel (standard)
Material:
S = Steel (standard)
Ports size:
B12 = 1/2” BSP (standard)
Stackable
Parallel inlet element
BD --3
S-
S P / 10
Nominal size
Seals:
N = NBR seals for mineral oil (standard)
V = FPM seals for special fluids
Series no.:
(the overall and mounting dimensions remain
unchanged from 10 to 19)
Material:
S = Steel (standard)
Ports size:
B12 = 1/2” BSP (standard)
Stackable
Parallel inlet element
Parallel inlet element with both pressure
control and unloading valves
BD --3 S P / 10
1.3 - Inlet element without pressure control valve
Pressure adjustment range:
140 = up to 140 bar
210 = up to 210 bar
320 = up to 320 bar
1.4 - Inlet element with pressure control valve
Seals:
N = NBR seals for mineral oil (standard)
V = FPM seals for special fluids
Series no.:
(the overall and mounting dimensions remain unchanged
from 10 to 19)
1.5 - Inlet element with both pressure control and unloading valves
/ /10PK - -
Coil electrical connection of the unloading valve:
K1 = plug for connector type EN 175301-803
(ex DIN 43650) (standard)
For D12 and D24 coils only:
K7 = plug DEUTSCH DT04-2P for male
connector type DEUTSCH DT06-2S
K2 plug for connector type AMP JUNIOR upon
request.
Manual override of the
unloading valve:
CS = screw
CP = push
CPK= push and twist
Pressure adjustment range:
140 = up to 140 bar
210 = up to 210 bar
320 = up to 320 bar
Nominal size
Ports size:
B12 = 1/2” BSP (standard)
Stackable
BD 3
Coil type of the unloading valve:
DC coil
D12 = 12 V
D24 = 24 V
D28 = 28 V
44 101/120 ED
5/28
BD*
SERIES 10
Nominal size
Series no.:
(the overall and mounting dimensions remain
unchanged from 10 to 19)
Material:
S = Steel (standard)
Ports size:
Omit for blind plate
B38 = 3/8” BSP
B12 = 1/2” BSP
Stackable
Outlet element (rear)
BD --3 S R / 10
1.7 - Outlet elements
Coil electrical connection of the
unloading valve:
K1 = plug for connector type EN 175301-
803 (ex DIN 43650) (standard)
For D12 and D24 coils only:
K7 = plug DEUTSCH DT04-2P for male
connector type DEUTSCH DT06-2S
K2 plug for connector type AMP JUNIOR
upon request.
Outlet port:
00 = blind plate
(do not use in stack assemblies for series connection)
01 = outlet port P
02 = outlet port T
03 = outlet port both for P and T
NOTE: if no unloading valve is needed,
the identification code ends with seals digit.
Example: BD3-B38S-P140-Q/10N
Material:
S = Steel (standard)
S- B38
Parallel inlet element with pressure relief valve
K = with unloading valve. Omit if not required.
Seals:
N = NBR seals for mineral oil (standard)
V = FPM seals for special fluids
Series no.:
(the overall and mounting dimensions remain unchanged
from 10 to 19)
1.6 - Inlet element for flow control valve
/ /10P -- Q-
Manual override of the
unloading valve:
CS = screw
CP = push
CPK= push and twist
Pressure relief valve adj. range:
140 = up to 140 bar
210 = up to 210 bar
320 = up to 320 bar
Mounting interface ISO 6263-03 style for flow control valve
(to be ordered separately, see catalogue 82220).
Nominal size
Ports size:
3/8” BSP (standard)
Stackable
BD 3
Coil type of the unloading valve:
DC coil
D12 = 12 V
D24 = 24 V
D28 = 28 V
2 - HYDRAULIC FLUIDS
Use mineral oil-based hydraulic fluids HL or HM type, according to ISO 6743-4. For these fluids, use NBR seals (code N). For fluids HFDR type
(phosphate esters) use FPM seals (code V). For the use of other kinds of fluid such as HFA, HFB, HFC, please consult our technical
department.
Using fluids at temperatures higher than 80 °C causes a faster degradation of the fluid and of the seals characteristics.The fluid must be
preserved in its physical and chemical characteristics.
44 101/120 ED
6/28
BD*
SERIES 10
3 - CHARACTERISTIC CURVES
(values obtained with viscosity 36 cSt at 50 °C)
3.1 - BDL
Values obtained with one element BDL2-B38A (thickness 38, ports 3/8” BSP)
SPOOL TYPE
FLOW DIRECTION
P→A P→B A→T B→T P→T
CURVES ON GRAPHS
S1, SA1, SB1 1 1 3 3 -
S2, SA2, SB2 2 2 1 1 2
S3, SA3, SB3 3 3 2 2 -
S4, SA4, SB4 4 4 4 4 1
TA, TB 3 3 3 3 -
TA02, TB02
3.3 - BDS
Values obtained with one element BDS3-B12 (thickness 46, ports 1/2” BSP)
SPOOL TYPE
FLOW DIRECTION
P→A P→B A→T B→T P→T
CURVES ON GRAPHS
S1, SA1, SB1 1 1 1 1 -
S2, SA2, SB2 2 2 2 2 2
S3, SA3, SB3 1 1 2 2 -
S4, SA4, SB4 4 4 4 4 1
TA, TB 2 2 2 2 -
TA02, TB02 1 1 1 1 -
SPOOL TYPE
FLOW DIRECTION
P→A P→B A→T B→T P→T
CURVES ON GRAPHS
S1, SA1, SB1 1 1 1 1 -
S2, SA2, SB2 2 2 2 2 2
S3, SA3, SB3 1 1 2 2 -
S4, SA4, SB4 4 4 4 4 1
TA, TB 1 1 1 1 -
TA02, TB02 1 1 1 1 -
3.2 - BDM
Values obtained with one element BDM3-B38 (thickness 46, ports 3/8” BSP)
44 101/120 ED
7/28
BD*
SERIES 10
4.3 - BDS
4.2 - BDM
4 - OPERATING LIMITS
The curves define the flow rate operating fields according to the valve pressure of the different versions. The values have been obtained
according to ISO 6403 norm with solenoids at rated temperature and supplied with voltage equal to 90% of the nominal voltage.
Values obtained with mineral oil, viscosity 36 cSt, temperature 50 °C and filtration according to ISO 4406:1999 class 18/16/13.
4.1 - BDL
SPOOL TYPE
S1, SA1, SB1 1
S2, SA2, SB2 2
S3, SA3, SB3 3
S4, SA4, SB4 4
S4, SA4, SB4 reverse flow 4*
TA, TB 4
TA02, TB02 1
SPOOL TYPE
S1, SA1, SB1 1
S2, SA2, SB2 2
S3, SA3, SB3 3
S4, SA4, SB4 4
S4, SA4, SB4 reverse flow 4*
TA, TB 2
TA02, TB02 1
SPOOL TYPE
S1, SA1, SB1 1
S2, SA2, SB2 1
S3, SA3, SB3 2
S4, SA4, SB4 1
S4, SA4, SB4 reverse flow 1*
TA, TB 1
TA02, TB02 1
NOTE: The reverse flow condition occurs in series circuits
made with elements for parallel connection, in even-position
elements only.
See scheme at par. 13.2
44 101/120 ED
8/28
BD*
SERIES 10
6 - ELECTRICAL FEATURES
6.1 - Solenoids
These are essentially made up of two parts: tube and coil. The tube
is threaded into the valve body and includes the armature that
moves immersed in oil, without wear. The inner part, in contact with
the oil in the return line, ensures heat dissipation. The coil is
fastened to the tube by a threaded ring, and can be rotated to suit
the available space.
6.2 - Protection from atmospheric agents IEC 60529
The IP protection degree is guaranteed only with both valve and
connectors of an equivalent IP degree, correctly connected and
installed.
The protection degree IP69K is not taken into account in IEC 60529
but it is included in ISO 20653.
SUPPLY VOLTAGE FLUCTUATION
± 10% Vnom
MAX SWITCH ON FREQUENCY
10.000 ins/hr
DUTY CYCLE
100%
ELECTROMAGNETIC COMPATIBILITY
(EMC)
In compliance with
2014/30/EU
LOW VOLTAGE
In compliance with
2014/35/EU
CLASS OF PROTECTION
Coil insulation (VDE 0580)
Impregnation
class H
class F
protection referred to electrical connection / whole valve
IP65 IP66 IP67 IP68
IP69
IP69K
K1 EN 175301-803 x x
WK7 DEUTSCH DT04 male x x x x
6.3 - BDL (solenoid tube Ø14)
IP degrees
Current and absorbed power
(values ±5 %)
Resistance
20°C
[Ω]
Absorbed
current
[A]
Absorbed
power
[W]
Coil code
K1 WK7
D12 5,4 2,2 26,5 1902740 1903510
D24 20,7 1,16 27,8 1902741 1903511
D28 27,5 1,02 28,5 1902744 -
D48 82 0,58 28 1902745 -
5 - SWITCHING TIMES
Values obtained according to ISO 6403, with mineral oil with viscosity 36 cSt at 50°C.
TIMES [ms]
(±10%)
ENERGIZING DE-ENERGIZING
BDL 25 ÷ 75 15 ÷ 25
BDM 25 ÷ 75 15 ÷ 25
BDS 25 ÷ 75 15 ÷ 25
44 101/120 ED
9/28
BD*
SERIES 10
ELECTROMAGNETIC
COMPATIBILITY (EMC)
In compliance with
2014/30/EU
LOW VOLTAGE
In compliance with
2014/35/EU
CLASS OF PROTECTION
atmospheric agents (EN 60529)
coil insulation (VDE 0580)
Impregnation
IP65
class H
class H
6.4 - BDM (solenoid tube Ø19)
IP degrees
6.5 - BDS (solenoid tube Ø22)
Coils with letter ‘W’ feature a zinc-nickel surface treatment, that makes them resistant to exposure to the salt spray for 600 hours (test
performed according to UNI EN ISO 9227 and assessment test performed according to UNI EN ISO 10289).
The WK7D coils include a suppressor diode of pulses for protection from voltage peaks during switching. During the switching the diode
significantly reduces the energy released by the winding, by limiting the voltage to 31.4V in the D12 coils and to 58.9 V in the D24 coils.
IP degrees
Current and absorbed power
(values ±10 %)
protection referred to electrical connection whole valve
IP65
K1 EN 175301-803 x
K7 DEUTSCH DT04 male x
Resistance
20°C
[Ω]
Absorbed
current
[A]
Absorbed
power
[W]
Coil code
K1 K7
D12 4.98 2.41 28.9 1903560 1903650
D24 21 1.15 28 1903561 1903651
6.6 - Unloading valve, solenoid operated (inlet plates)
Current and absorbed power
(values ±10 %)
Resistance
20°C
[Ω]
Absorbed
current
[A]
Absorbed
power
[W]
D12 7 1.2 20.5
D24 28 0.6 20.5
protection referred to electrical connection whole valve
IP65 IP66 IP67 IP68
IP69
IP69K
IP65 IP66 IP67 IP68
IP69
IP69K
K1 EN 175301-803 (ex DIN 43650) x x
WK1 EN 175301-803 (ex DIN 43650) x x x x
K7 DEUTSCH DT04 male x x x
WK7 / WK7D DEUTSCH DT04 male x x x x x x x x x x
Current and absorbed power
(values ±10 %)
Resistance
at 20°C
[Ω]
Absorbed
current
[A]
Absorbed
power
[W]
Coil code
K1 K7 WK1 WK7 WK7D
D12 4,4 2,72 32,7 1903080 1902940 1903050 1903580 1903600
D24 18,6 1,29 31 1903081 1902941 1903051 1903581 1903601
D28 26 1,11 31 1903082 - - - -
D48 78,6 0,61 29,5 1903083 - - - -
44 101/120 ED
10/28
BD*
SERIES 10
7 - ELECTRICAL CONNECTIONS
7.1 - BDL
connection for EN 175301-803
(ex DIN 43650) connector
code K1 (standard)
7.2 - BDM
DEUTSCH DT04-2P connection for DEUTSCH
DT06-2S male connector
code WK7
connection for EN 175301-803
(ex DIN 43650) connector
code K1 (standard)
DEUTSCH DT04-2P connection for DEUTSCH
DT06-2S male connector
code K7
7.3 - BDS
8 - ELECTRICAL CONNECTORS
The solenoid valves are supplied without connectors. Connectors for electrical connections K1 and WK1 (EN 175301-803, ex DIN 43650) can
be ordered separately. See catalogue 49 000.
connection for DEUTSCH DT06-2S male connector
code K7
connection for DEUTSCH DT06-2S male connector
code WK7 (W7 version only)
code WK7D (W7 version only - coil with diode)
connection for EN 175301-803 (ex DIN 43650) connector
code K1 (standard)
code WK1 (W7 version only)
44 101/120 ED
11/28
BD*
SERIES 10
Valve
type
Valve
qty.
KIT code
BDL2
BDM2
3 3404100100
4 3404100101
5 3404100102
6 3404100103
7 3404100104
8 3404100105
9 3404100106
BDL3
BDM3
BDS3
3 3404100108
4 3404100109
5 3404100110
6 3404100111
Tightening torque: 20 (0 / +3) Nm
1 galvanized trapped screw
2 galvanized nut
3 galvanized safety washer
9 - INSTALLATION
The stacked valve assembly can be installed in any position without impair the proper functioning.
9.1 - Fixing and tie-rods
Please contact the technical dept. for dimensional check of special assemblies before order.
44 101/120 ED
12/28
BD*
SERIES 10
10 - OVERALL AND MOUNTING DIMENSIONS OF DIRECTIONAL VALVES
10.1 - BD* - mounting surfaces
10.2 - BD* directional valve element - bodies
dimensions in mm
dimensions in mm
ØB ØC
Seals
standard
9 14
2 OR type 2043 (10.82x1.78)
A variant 7.5 12
2 OR type 2037 (9.25x1.78)
picture A - BD*3
with mounting surface
for flangeable element
available ports:
B38 or S06
picture B - BD*3
available ports:
B12 or S08
picture C - BD*2
available ports:
B38 or S06
NOTE: the variant is available adding A after ports size in the
identification code.
Example: BDL3-B38A-S1/10
44 101/120 ED
13/28
BD*
SERIES 10
10.3 - BDL - Directional valve element - solenoid tube ø14
1 Mounting surface with sealing
rings
2 A and B ports: 3/8” BSP
3 A and B ports: 3/8” BSP
with mounting interface for
flangeable elements
4 A and B ports: 1/2” BSP
5 Locking ring with embedded boot
manual override.
ring tightening torque: 3 Nm
6 Coil removal space
7 EN 175301-803 (ex DIN 43650)
connector removal space
8 EN 175301-803 (ex DIN 43650)
connector for K1 coil connection
To be ordered separately.
9 Element label
BDL2 - B38
BDL3 - B38
BDL3 - B12
dimensions in mm
44 101/120 ED
14/28
BD*
SERIES 10
10.4 - BDM - Directional valve element - solenoid tube ø19
1 Mounting surface with sealing
rings
2 A and B ports: 3/8” BSP
3 A and B ports: 3/8” BSP
with mounting interface for
flangeable elements
4 A and B ports: 1/2” BSP
5 Locking ring with manual
override (pin) embedded in the
tube.
Ring tightening torque: 5 Nm
6 Coil removal space
7 EN 175301-803 (ex DIN 43650)
connector removal space
8 EN 175301-803 (ex DIN 43650)
connector for K1 coil connection
To be ordered separately.
9 Element label
BDM2- B38
BDM3- B38
BDM3- B12
dimensions in mm
44 101/120 ED
15/28
BD*
SERIES 10
10.5 - BDS - Directional valve element - solenoid tube ø22
1 Mounting surface with sealing
rings
2 A and B ports: 3/8” BSP
with mounting interface for
flangeable elements
3 A and B ports: 1/2” BSP
4 Locking ring with manual
override (pin) embedded in the
tube.
Ring tightening torque: 5 Nm
5 Coil removal space
6 EN 175301- 803 (ex DIN 43650)
connector removal space
7 EN 175301- 803 (ex DIN 43650)
connector for K1 coil connection
To be ordered separately.
8 Element label
BDS3 - B38
BDS3- B12
dimensions in mm
44 101/120 ED
16/28
BD*
SERIES 10
BDS* /CMBDM* /CMBDL
10.6 - CM - boot protected
The BDL standard element is already equipped with boot protection of the solenoid tube. For both BDM and BDL elements add /CM at the end
of the code.
dimensions in mm
BDS* /CK1BDM* /CK1BDL* /CK1
Max stroke: 4.5 mm
mm per turn: 1
Max stroke: 5.5 mm
mm per turn: 1
Max stroke: 6.5 mm
mm per turn: 1.25
10.7 - CK1 - knob manual override, turning
dimensions in mm
44 101/120 ED
17/28
BD*
SERIES 10
10.8 - CHL light duty lever manual override
Devices are placed on side A. Please contact our technical depth for other positions. For non-quoted dimensions, please refer to the overall
tables in previous pages.
The CHL lever device can work with a maximum pressure in line T up to 50 bar, therefore it is not suitable for series circuits.
BDL2-* /CHL
BDM3-* /CHL
BDS3-* /CHL
dimensions in mm
11 - DIMENSIONS OF INLET AND OUTLET  ELEMENTS FOR PARALLEL CIRCUITS
11.1 - Inlet elements
dimensions in mm
BD3-B12S-P***
with pressure control valve
BD3-B12S-P
without pressure control valve
1 Mounting surface with sealing
rings:
2 OR type 2043 (10.82x1.78)
2 P and T ports: 1/2” BSP
3 Pressure gauge port: 1/4” BSP
4 Element label
1 Pressure control valve
2 Locking nut: spanner 13
3 Socket hex adjustment screw:
Allen key 4
Clockwise rotation to increase
pressure
4 Maximum screw stroke
5 Mounting surface with sealing
rings:
2 OR type 2043 (10.82x1.78)
6 P and T ports: 1/2” BSP
7 Pressure gauge port:1/4” BSP
8 Element label
44 101/120 ED
18/28
BD*
SERIES 10
44 101/120 ED
19/28
BD*
SERIES 10
dimensions in mm
1 Pressure control valve
2 Locking nut: spanner 13
3 Socket hex adjustment screw:
Allen key 4
Clockwise rotation to increase
pressure
4 Maximum stroke
5 Mounting surface with sealing
rings:
2 OR type 2043 (10.82x1.78)
6 P and T ports: 1/2” BSP
7 Pressure gauge port:1/4” BSP
8 Unloading valve
Here shown with K1 connection
9 Push and twist manual override:
see identification codes for
further choices.
10 Element label
BD3-B12S-PK***
with pressure control and
unloading valve
NOTE: for missing dimensions of mounting interface
please refer to par. 10.1 ’mounting surfaces’.
44 101/120 ED
20/28
BD*
SERIES 10
11.2 - Inlet elements for flow control valve
dimensions in mmBD3-B38S-PK***-Q
with pressure control and
unloading valves
NOTE :The same component
without part no. 8 is:
BD3-B38S-P***-Q
with pressure control
without unloading valve
NOTE: for missing dimensions of mounting interface
please refer to par. 10.1 ’mounting surfaces’.
1 Pressure control valve
2 Locking nut: spanner 13
3 Socket hex adjustment screw:
Allen key 4
Clockwise rotation to increase
pressure
4 Maximum stroke
5 Mounting surface with sealing
rings:
2 OR type 2043 (10.82x1.78)
6 P and T ports: 3/8” BSP
7 Pressure gauge port: 1/4” BSP
8 Unloading valve
Here shown with K1 connection
9 Push and twist manual override:
see identification codes for
further choices.
10 Element label
11 Encumbrance of flow control
valve. To be ordered separately.
See catalogue 82 220
44 101/120 ED
21/28
BD*
SERIES 10
BD3-S-R00
blind plate
Code 0194019
NOTE: for missing dimensions
of mounting interface
please refer to par. 10.1
’mounting surfaces’.
11.3 - Outlet elements
dimensions in mm
1 n° 3 through holes for stack
assembly tie-rods
BD3-B38S-R01
plate with P1 outlet
Code 0194062
1
n° 3 through holes for stack
assembly tie-rods
2
P1 port: 3/8 BSP
BD3-B38S-R02
plate with T1 outlet
Code 0194055
1
n° 3 through holes for stack
assembly tie-rods
2
T1 port: 3/8 BSP
44 101/120 ED
22/28
BD*
SERIES 10
dimensions in mm
NOTE: for missing dimensions of mounting interface
please refer to par. 10.1 ’mounting surfaces’.
BD3-B38S-R03
plate with P1 and T1 outlet
Code 0194063
1
n° 3 through holes for stack
assembly tie-rods
2
P1 and T1 ports: 3/8” BSP
44 101/120 ED
23/28
BD*
SERIES 10
12 - IDENTIFICATION CODE FOR STACKED VALVE ASSEMBLY
13 - CONNECTION SCHEMES EXAMPLES
13.1 - BD**-P parallel connection
Parallel circuit is obtained with elements for parallel connection (see par. 1).
Seals:
N = NBR seals for mineral oil (standard)
V = FPM seals for special fluids
Series no.:
(the overall and mounting dimensions remain
unchanged from 10 to 19)
Stacked valve
assembly
Circuit type:
P = parallel
S = series (parallel elements with plugs)
C = series (series elements)
Available for size 2 only
Configuration code (5 digits),
assigned by Duplomatic
No. of directional valves
BD -10 /
-
/
XXXXX
Solenoid tube (mm):
L= 14
M= 19
S= 22 (only size 3)
Coil type:
DC coils
D12 = 12 V
D24 = 24 V
D28 = 28 V
D00 = valve without coil supplied with
locking ring
Coil electrical connection:
K1 = plug for connector type EN 175301-803
(ex DIN 43650) (standard)
K7 = plug DEUTSCH DT04-2P for male connector
type DEUTSCH DT06-2S
Size:
2 = thickness 38 mm
3 = thickness 46 mm
inlet
plate
S1
spool
S1
spool
outlet
plate
R00
44 101/120 ED
24/28
BD*
SERIES 10
13.2 - BD**-S series connection
Series circuit is obtained by inserting plugs in elements for parallel connection (see par. 1).
Please note that this kind of configuration requires a different outlet plate, depending on the number (even or odd) of directional valves in the
assembly.
13.3 - BDL2-C and BDM2-C series connection
BD*2-C series connection is obtained with elements designed for series (see par. 14). The series elements are available in size 2 only.
plug Ø9 - ordering code: 0612253
plugs
inlet
plate
S4
spool
S4
spool
outlet
plate
R01
inlet
plate
S4
spool
S4
spool
outlet p.
R02
inlet
plate
S4
spool
S4
spool
S4
spool
outlet
plate
R02
plugs
44 101/120 ED
25/28
BD*
SERIES 10
Seals:
N = NBR seals for mineral oil (standard)
V = FPM seals for special fluids
Series no.
(the overall and mounting dimensions remain unchanged
from 10 to 19)
Size = thickness 38 mm
Solenoid tube (mm):
L= 14
M= 19
Ports:
B38 = 3/8” BSP
S06 = 9/16” 18 UNF (SAE 06))NF (SAE 06)
Spool type
Series design
with sloped hole for T1 path.
Stack directional
valve element, on-off
BD 2 - -C S4 / 10 /-
Coil type (see paragraph 1.1)
Coil electrical connection: (see paragraph 1.1)
Manual override (see par. 10.6 - 10.8):
for BDL:
omit for manual override boot protected
integrated in the coil locking ring (standard)
CK1 = turning knob override
for BDM:
omit for pin manual override integrated in
the tube (standard).
CM = manual override boot protected
CK1 = turning knob override
14 - IDENTIFICATION CODES OF SEPARATE ELEMENTS FOR BDL2 AND BDM2 SERIES CIRCUITS
14.1 - Directional valve element
This code identifies BD*2 elements, designed for series connection. Series circuits with BD*3 modules are feasible by inserting plugs to divert
the oil path (see paragraph 13.2).
NOTE: if no unloading valve is needed,
the identification code ends with seals digit.
Example: BD3-B38S-S140-Q/10N
Material:
S = Steel (standard)
S- B38
Series inlet element with pressure relief valve
K = with unloading valve. Omit if not required.
Seals:
N = NBR seals for mineral oil (standard)
V = FPM seals for special fluids
Series no.:
(the overall and mounting dimensions remain unchanged
from 10 to 19)
14.2 - Inlet elements for flow control valve
/ /10S -- Q-
Manual override of unloading
valve:
CS = screw
CP = push
CPK= push and twist
Pressure relief valve adj. range:
140 = up to 140 bar
210 = up to 210 bar
320 = up to 320 bar
Mounting interface ISO 6263-03 style for flow control valve
(to be ordered separately, see catalogue 82220).
Nominal size
Ports size:
3/8” BSP (standard)
Stackable
BD 3
Coil type of the unloading valve:
DC coil
D12 = 12 V
D24 = 24 V
D28 = 28 V
Coil electrical connection of the unloading
valve:
K1 = plug for connector type EN 175301-803
(ex DIN 43650) (standard)
For D12 and D24 coils only:
K7 = plug DEUTSCH DT04-2P for male
connector type DEUTSCH DT06-2S
K2 plug for connector type AMP JUNIOR
upon request.
14.3 - Outlet elements
Please choose the proper outlet element amongst those in paragraph 1.7. Overall dimensions are at paragraph 11.3.
15 - CHARACTERISTIC CURVES AND OPERATING LIMITS FOR SERIES
Please refer to diagrams at par. 3 for pressure drops, whereas operating limits are here below.
15.1 - BDL2-B38C-S4 15.2 - BDM2-B38C-S4
16 - DIMENSIONS OF ELEMENTS FOR SERIES CONNECTION
16.1 - BD*2-B38C-S4/10* - directional valve element
The BDM2 configuration is showed here. The same directional valve is available as BDL2. For non-quoted dimensions, please refer to the
drawings for parallel circuits. Overall dimensions are the same.
44 101/120 ED
26/28
BD*
SERIES 10
dimensions in mm
1 Mounting surface with sealing ring:
1 OR type 2043 (10.82x1.78)
2 A and B ports: 3/8” BSP
44 101/120 ED
27/28
BD*
SERIES 10
16.2 - Inlet elements for flow control valve
dimensions in mmBD3-B38S-SK***- Q
with pressure control and
unloading valves
NOTE :The same component
without part no. 8 is:
BD3-B38S-S***-Q
with pressure control
without unloading valve
NOTE: for missing dimensions of mounting interface
please refer to the par 10.1 ’mounting surfaces’.
1 Pressure control valve
2 Locking nut: spanner 13
3 Socket hex adjustment screw:
Allen key 4
Clockwise rotation to increase
pressure
4 Maximum screw stroke
5 Mounting surface with sealing
rings:
2 OR type 2043 (10.82x1.78)
6 P and T ports: 3/8” BSP
7 Pressure gauge port:1/4” BSP
8 Unloading valve
Here shown with K1 connection
9 Push and twist manual override:
see identification codes for
further choices.
10 Element label
11 Encumbrance of flow control
valve. To be ordered separately.
See catalog 82220
44 101/120 ED
28/28
BD*
SERIES 10
REPRODUCTION IS FORBIDDEN. THE COMPANY RESERVES THE RIGHT TO APPLY ANY MODIFICATIONS.