The BLS6 directional control valve is stackable and can be
assembled up to 8 different proportional and on/off
modules .
Each module is equipped with a meter-in compensator that
keep costant the flow, independently from load changes.
— Sections with pressure compensators are not influenced in
any way by other operated functions, provided that
sufficient pump capacity is available. To correctly work, the
sum of the flows contemporarily used must not overcome
the 90% of the inlet flow.
The user ports A and B are threaded 1/2” BSP. On the inlet
module the ports P1, P2 and T1 are threaded 3/4” BSP.
The manual lever override is available as option.
BLS6
BANKABLE LOAD SENSING
PROPORTIONAL
CONTROL VALVE
SERIES 11
HYDRAULIC SYMBOL
OPERATING PRINCIPLE
44 150/112 ED
p max 300 bar
Q max 120 l/min
Maximum operating pressure:
- A and B ports
- P1 and P2 ports
- T1 port
bar
300
250
20
Maximum flowrate:
- A and B ports
- P1 and P2 ports
- T1 port
l/min
45
100
120
Electrical characteristics see paragraph 5
Ambient temperature range °C -20 / +60
Fluid temperature range °C -20 / +80
Fluid viscosity range cSt 10 ÷ 400
Fluid contamination degree
According to ISO 4406:1999
class 18/16/13
Recommended viscosity cSt 25
Single body mass kg 4,5
Surface treatment of body and plates thermochemical antioxidant
PERFORMANCES (obtained with mineral oil with viscosity of 36 cSt at 50°C )
1/14
44 150/112 ED
T1
T1
1 - IDENTIFICATION CODES FOR LOOSE MODULES
Seals:
V = FPM seals (standard)
Solenoid position:
(omit for configuration with two solenoids)
A = 1 solenoid on side A
B = 1 solenoid on side B
Size
Spool nominal flow (see below)
Spool type:
PC = closed centers
PA = open centers
Compensated direct operated
directional valve with
proportional control
BLS 6 - / 11 V - /
Coil electrical connection:
(see paragraph)
K1 = plug for connector type
DIN 43650 (standard)
K7 = plug for connector type
DEUTSCH DT04-2P male
1.1 - Proportional module
Here below all the loose components identification codes of the bankable valve are shown. To order a whole assembled valve, please use the
codes at paragraphes 9 and 10.
The inlet section is available in different version for fixed pump and for system with Load Sensing pump.
Series no. (the overall and mounting dimensions remain
unchanged from 10 to 19)
Coil type:
D12 = Nominal solenoid voltage 12V DC
D24 = Nominal solenoid voltage 24V DC
Manual override
(see par. 11)
SPOOLS
Valve configuration depends on the combination of the following elements:
number of proportional solenoids, spool type, nominal flow rate.
2 solenoids configuration:
3 positions with spring centering
1 solenoid on side A.
2 positions (central + external) with
spring centering
1 solenoid on side B.
2 positions (central + external) with
spring centering
ASYMMETRICAL
max flow ∆p
15/10 4
25/15 8
30/20 4
45/30 8
SYMMETRICAL
max flow ∆p
15/15 4
25/25 8
30/30 4
45/45 8
SINGLE FLOW
max flow ∆p
30 4
45 8
BLS6
SERIES 11
2/14
44 150/112 ED
The inlet section is available in different version, for fixed and for variable pumps with load sensing. The version for fixed pump can be easily
converted to work with variable pumps and vice versa.
Seals:
V = FPM seals (standard)
Series no.: (the overall and mounting dimensions
remain unchanged from 10 to 19)
Nominal size
C0 = without compensator (NOTE)
CF = for fixed pump
CV = for variable pump
Pressure adjustment range:
0 = no relief valve
5 = from 12 to 210 bar
6 = from 15 to 315 bar
Compensated direct
operated directional valve
with proportional control
BLS 6 - / 11 V
Series no.: (the overall and mounting dimensions
remain unchanged from 10 to 19)
Nominal size
C91 = without load sensing port
C92 = with load sensing port
Compensated direct
operated directional valve
with proportional control
BLS 6 - / 11
1.3 - Inlet modules
If necessary the proportional spool can be used together with on-off solenoids. In this case the description for the spool type as to be as
follow:
SC = closed center with on-off solenoid
SA = open center with on-off solenoid
In this version is also available a spool for high flow named SC60/60 and SA60/60.
1.2 - On-off modules
1.4 - End plate modules
NOTE: The version C0 is available only without the pressure relief valve, code BLS6-C00/11V.
BLS6
SERIES 11
3/14
44 150/112 ED
2 - HYDRAULIC FLUIDS
Use mineral oil-based hydraulic fluids HL or HM type, according to ISO 6743-4 or fluids HFDR type. For the use of other kinds of fluid such as
HFA, HFB, HFC, please consult our technical department. Using fluids at temperatures higher than 80 °C causes a faster degradation of the
fluid and of the seals characteristics.
The fluid must be preserved in its physical and chemical characteristics.
3 - CHARACTERISTIC CURVES (values obtained with viscosity 36 cSt at 50 °C)
PROPORTIONAL MODULES PRESSURE DROPS ∆p-Q
Typical constant flow rate obtained with internal 2-way compensator, and current with 12V solenoid type (for D24 version the maximum current
is 860 mA), measured for the various spool types available.
SYMMETRICAL FLOWS - PC AND PA SPOOLS
ASYMMETRICAL FLOWS - PC AND PA SPOOLS
FLOWRATE - PRESSURE Q= f(p) CV-CF INLET MODULE PRESSURE DROPS p= f(Q)
BLS6
SERIES 11
4/14
44 150/112 ED
BLS6
SERIES 11
5/14
44 150/112 ED
4 - ELECTRICAL CHARACTERISTICS
5 - STEP RESPONSE
(measured with mineral oil with viscosity of 36 cSt at 50°C with the relative
electronic control units)
Proportional solenoid
The proportional solenoid comprises two parts: tube and coil.
The tube, screwed to the valve body, contains the armature which
is designed to maintain friction to a minimum thereby reducing
hysteresis.
The coil is mounted on the tube secured by means of a lock nut.
It can be rotated through 360° depending on installation clearances.
Step response is the time (delay) taken for the valve to reach 90%
of the set position value following a step change of the reference
signal.
Reference
signal step
0 →100% 100 →0%
Step response [ms]
BLS6 50 40
6 - ELECTRIC CONNECTIONS
connection for DIN 43650 connector
code K1 (standard)
connection for DEUTSCH DT04-2P connector type
code K7
7 - ELECTRIC CONNECTORS
The on-off valves are supplied without connectors. For coils with standard electrical connections K1 type (DIN 43650) the connectors can be
ordered separately. For the identification of the connector type to be ordered please see cat. 49 000. Connectors for K7 connections are not
available.
coil
center line
Plug-in type IP 65 IP 69 K
K1 DIN 43650 x (*)
K7 DEUTSCH DT04 male x x (*)
Protection from atmospheric agents CEI EN 60529
(*) The protection degree is guaranteed only with the connector
correctly connected and installed
NOMINAL VOLTAGE V DC 12 24
RESISTANCE (at 20°C) K1 COIL
K7 COIL
3.66
4
17.6
19
NOMINAL CURRENT
A 1.88 0.86
DUTY CYCLE
100%
PWM FREQUENCY
Hz 200 100
ELECTROMAGNETIC COMPATIBILITY
(EMC)
According to
2004/108/CE
CLASS OF PROTECTION :
Coil insulation (VDE 0580)
Impregnation:
class H
class F
8 - OVERALL AND MOUNTING DIMENSIONS
8.1 - Proportional module
dimensions in mm
1 Mounting surface with
sealing rings:
n° 4 OR 2056 (14x1.78)
90 shore
2 Locking ring with boot
protected manual override
3 Coil removal space
4 Electrical connector type
DIN 43650 (drawing with
standard type K1 - for other
connections see par. 6)
5 Connector removal space
1 SOLENOID
2 SOLENOIDS
BLS6-PC*
BLS6-PA*
BLS6-PCB*
BLS6-PAB*
BLS6
SERIES 11
6/14
44 150/112 ED
n° 6 holes M6x10
solenoid position for PCA*
and PAA* configurations
BLS6
SERIES 11
7/14
44 150/112 ED
8.2 - Inlet modules
dimensions in mm
BLS6-C00
1 Mounting surface with
sealing rings:
n° 4 OR 2056 (14x1.78)
90 shore
2 Load Sensing port:
1/4”BSP with orifice
3 P1, P2 and T1 ports:
3/4” BSP
4 Pressure gauge port:
1/4” BSP
for fixing
8.2 - Inlet modules
dimensions in mm
BLS6-CF*
BLS6-CV*
for fixing
BLS6
SERIES 11
8/14
44 150/112 ED
1 Mounting surface with
sealing rings:
n° 4 OR 2056 (14x1.78)
90 shore
2 Load Sensing port:
1/4” BSP
3 P1, P2 and T1 ports:
3/4” BSP
4 Pressure gauge port:
1/4” BSP
5 T2 port: 1/2” BSP
6 Special plug for the
pressure relief valve seat.
(D). Orifice seat “A”
underneath.
BLS6-CF0
orifice “C” underneath
orifice seat “B”
underneath, on the spool
orifice seat “E”
underneath
“E”
8.3 - End modules
dimensions in mm
1 Mounting surface
with no sealing rings
2 T1 outlet: 3/8” BSP
3 Identification label
4 Load Sensing port:
1/4” BSP
5 Identification label
BLS6-C91
n° 2 holes fox fixing M8x13
BLS6
SERIES 11
9/14
44 150/112 ED
BLS6-CF5
BLS6-CF6
BLS6-CV5
BLS6-CV6
BLS6-C92
“E”
“E”
Inlet module:
C0 = without compensator (NOTE)
CF = for fixed pump
CV = for variable pump
Coding example:
BLS6-C00-PC30/30-PC30/30-C92/11V-D24K1: assembled valve includes: inlet module without 3 way compensator; 2 prop.
modules with closed center flow 30/30; end plate without load sensing port; FPM seals, 24V DC coils and K1 connection.
BLS6-CF5-PA45/30-PA45/30-PC30/30-PAB15/15-C91/11V-D12K1: assembled valve includes: inlet module for fixed pump, with
pressure max 210 bar; 2 prop. modules with open center flow 45/30, 1 prop. module with close center, flow 30/30 and 1 prop. module
with open center and solenoid only on side B, flow 15/15; end plate with load sensing port; FPM seals, 12V DC coils and K1 connection.
NOTE: To obtain the best performances, we suggest to mount the spool with the max flow first, and then the others
decreasing.
9 - IDENTIFICATION CODE OF ASSEMBLED VALVE
Seals:
V = FPM seals (standard)
Series no.: (the overall and mounting
dimensions remain unchanged from 10 to 19)
Compensated direct
operated directional
valve with proportional
control
BLS6 - / 11 V -
-
- -
Coil type:
D12 = Nominal solenoid voltage 12V DC
D24 = Nominal solenoid voltage 24V DC
Coil electrical connection:
(see paragraph 9)
K1 = plug for connector type
DIN 43650 (standard)
K7 = plug for connector type
DEUTSCH DT04-2P male
BLS6
SERIES 11
10/14
44 150/112 ED
NOTE: The version C0 is available only without the pressure relief valve, wiith code BLS6-C00/11V.
Pressure adjustment range:
0 = no relief valve
5 = from 12 to 210 bar
6 = from 15 to 315 bar
End plate:
C91 = without load sensing port
C92 = with load sensing port
Proportional module:
Choose open or closed center, and then the
spool type, like code in par. 1.1
Repeat for each proportional module required,
max 8 modules.
/
Manual override on all
proportional modules
(see par. 13)
10 - INSTALLATION AND OVERALL DIMENSIONS OF THE ASSEMBLED VALVE 
dimensions in mm
1 Inlet module
2 Pressure relief valve
3 Proportional modules
4 End plate
5 Fixing studs
6 Fixing holes
7 Manual lever override
module
BLS6
SERIES 11
11/14
44 150/112 ED
Fixing kit
No. of body
modules
Code
2 3404150010
3 3404150011
4 3404150012
5 3404150013
6 3404150014
7 3404150015
8 3404150016
The fixing kit includes n° 3 studs,
3 self locking nuts and 3 washers,
all zinc-coated.
To order it please use the following
codes:
Modules
A
(NOTE)
B
2 212 132,5
3 262 182,5
4 312 232,5
5 362 282,5
6 412 332,5
7 462 382,5
8 512 432,5
NOTE: with the inlet module
BLS6-C00 the dimension
results 10 mm shorter.
Tightening torque: 25 Nm
(NOTE)
44 150/112 ED
12/14
BLS6
SERIES 11
11 - MANUAL OVERRIDE
The standard valve has solenoids whose pin for the manual operation is integrated in the tube. The operation of this control must be executed
with a suitable tool, minding not to damage the sliding surface.
Four different manual override version are available upon request:
- CM version, manual override belt protected.
- CS version, with metal ring nut provided with a M4 screw and a blocking locknut to allow the continuous mechanical operations.
- CH version, lever manual override.
- CK version, knob. When the set screw is screwed and its point is aligned with the edge of the knob, tighten the knob till it touches the spool:
in this position the override is not engaged and the valve is de-energized. After adjusting the override, tighten the set screw in order to avoid
the knob loosing.
CM Version CS Version
Code: 3803210003 Code: 3803210004
CH Version
max stroke 6.4
CK Version
Spanner for set screw: 3 mm
Code: 3803210005
44 150/112 ED
13/14
BLS6
SERIES 11
These cards drive only a module at once.
Every module to be driven with electronic card must have its
one.
Two solenoids
One solenoid
12 - ELECTRONIC CONTROL UNITS
EDM-M211 for solenoid 24V DC
rail mounting
DIN EN 50022
see cat. 89 250
EDM-M241 for solenoid 12V DC
EDC-111 for solenoid 24V DC
plug version
see cat. 89 120
EDC-141 for solenoid 12V DC
EDM-M111 for solenoid 24V DC
DIN EN 50022
rail mounting
see cat. 89 250
EDM-M141 for solenoid 12V DC
13 - EXAMPLES OF APPLICATION
BLS6 valve for fixed diplacement pumps with pressure relief valve.
BLS6 valve for systems with LS pump. The system is equipped with a pilot-operated relief valve, protecting the
pump.
44 150/112 ED
14/14
DUPLOMATIC OLEODINAMICA S.p.A.
20015 PARABIAGO (MI)  Via M. Re Depaolini 24
Tel. +39 0331.895.111
Fax +39 0331.895.339
www.duplomatic.com  e-mail: sales.exp@duplomatic.com
BLS6
SERIES 11
REPRODUCTION IS FORBIDDEN. THE COMPANY RESERVES THE RIGHT TO APPLY ANY MODIFICATIONS.
Example of two BLS6 valves linked with parallel connection for the pump and serial connection for LS port.