43 100/117 ED
4/8
KT08
SERIES 10
6 - OVERALL AND MOUNTING DIMENSIONS
5 - ELECTRICAL FEATURES
5.1 - Solenoids
These are essentially made up of two parts: tube and coil. The tube is threaded onto the valve body and includes the armature that moves
immersed in oil, without wear. The inner part, in contact with the oil in the return line, ensures heat dissipation. The coil is fastened to the tube
by a threaded nut, and can be rotated according to the available space.
The interchangeability of coils of different voltages both D or R type is possible without removing the tube.
Protection from atmospheric agents IEC 60529
The IP protection degree is intended for the whole valve. It is
guaranteed only with both valve and connectors of an equivalent IP
grade, correctly connected and installed.
Versions with CM manual override are IP65 always.
5.2 - Current and absorbed power
In the table are shown current and power consumption values relevant to the different coil types. “R” coil must be used when the valve is fed
with AC power supply subsequently rectified by means of rectifier bridge, externally or incorporated in the “D” type connector (see cat. 49 000).
Resistance at
20°C
[Ω] (±1%)
Absorbed
current
[A] (±5%)
Absorbed power
(±5%)
[W] [VA]
Coil code
K1 K2 K4 WK7 WK8
D12 5,4 2,2 26,5 1902740 1902750 1902770 1903510 1903520
D24 20,7 1,16 27,8 1902741 1902751 1902771 1903511 1903521
R110 363 0,25 27,2 1902742
R230 1640 0,11 26,4 1902743
SUPPLY VOLTAGE FLUCTUATION ± 10% Vnom
MAx SWITCH ON FREQUENCY 10.000 ins/hr
DUTY CYCLE 100%
ELECTROMAGNETIC COMPATIBILITY
(EMC)
In compliance with
2014/30/EU
LOW VOLTAGE
In compliance with
2014/35/EU
CLASS OF PROTECTION :
Coil insulation (VDE 0580)
Impregnation:
class H
class H
36
6
23.5
48
75
7
15
dimensions in mm
1 Coil removal space
2 OR type 4081 (20.22x3.53)
3 Hexagonal: spanner 27 - tightening torque 50 Nm
4 OR type 3.908 (16.36x2.21)
5 OR type 2037 (9.25x1.78) - 90 Shore
6 Electric connector EN 175301-803 (ex DIN 43650)
(drawing relevant to standard connection K1 - for other
types of connection see paragraph 7)
7 Connector removal space
(*) The protection degree IP69K is not taken into account in
IEC 60529 but it is included in both ISO 20653.
Electric connection IP65 IP66 IP67 IP68
IP69
IP69K (*)
K1 EN 175301-803 x x
K2 AMP JUNIOR x x
K4 outgoing cables x
WK7 DEUTSCH DT04 male x x x x
WK8 AMP SUPER SEAL x x x x x