41 600/117 ED
2/6
DSH*
2 - SPOOL TYPE
1 - IDENTIFICATION CODE
Lever operated
Size:
3 = ISO 4401-03
5 = ISO 4401-05
Spool type (see par. 2)
S* SK* SA* SAK*
TA TAK
TA23 TAK23
Seals:
N = NBR seals for mineral oil (standard)
V = FPM seals for special fluids
Series No.:
11 for DSH3 (the overall and mounting dimensions
remain unchanged from 10 to 19)
30 for DSH5 (the overall and mounting dimensions
remain unchanged from 30 to 39)
Directional control valve
with spool
D S H - /
3 - HYDRAULIC FLUIDS
Use mineral oil-based hydraulic fluids HL or HM type, according to ISO 6743-4. For these fluids, use NBR seals (code N). For fluids HFDR type
(phosphate esters) use FPM seals (code V). For the use of other fluid types such as HFA, HFB, HFC, please consult our technical department.
Using fluids at temperatures higher than 80 °C causes a faster degradation of the fluid and of the seals characteristics. The fluid must be
preserved in its physical and chemical characteristics.
NOTE:
On request it is possible to have the lever mounted in different positions
from those in the catalogue. Please consult our Technical Department.
Type S*:
3 positions
with spring centering
Type TA:
2 external positions
with return spring
Type TAK:
2 external positions
with mechanical retention
Type SA*:
2 positions
(central + external)
with spring centering
Type SAK*:
2 positions
(central + external)
with mechanical retention
Type SK*:
3 positions
with mechanical retention
Besides the diagrams shown, which are the most frequently
used, other special versions are available: consult our
Technical Department for their identification and operating
limits.
NOTE: TA02,TA23, TAK02 and TAK23 spools are available
only for DSH3.