41 420/117 ED
1/12
41 420/117 ED
101.6
88.1
76.6
65.9
50
34.1
Y
Ø4
M10
Ø6.3(max)
BA
P
L
T
G
M6
X
G
18.3
Ø17.5(max)
71.5
69.8
57.2
55.6
34.9
15.9
14.3
1.6
DSP7
PILOT OPERATED DISTRIBUTOR
SOLENOID OR HYDRAULIC
(DSC7) CONTROLLED
The DSP7 piloted valve is made up of a 4-way hydro-
piloted distributor with mounting surface according to
ISO 4401-07 standards, operated by an ISO 4401-03
solenoid directional valve.
It is available with different spool types (see par. 2), with
some options for the opening control.
It is available with both the solenoid and the hydraulic
control from the X and Y ways.
A version for high pressures (H) is available.
It is available also with zinc-nickel surface treatments, that
ensures a salt spray resistance up to 600 hours.
MOUNTINGSURFACE
DSP7 DSP7H
Maximum operating pressure
- ports P - A - B
- port T (external drainage)
- port T (internal drainage)
bar
350
250
210 (DC) / 160 (AC)
420
350
210 (DC) / 160 (AC)
Maximum flow rate from port P to A - B - T l/min 300
Ambient temperature range °C -20 / +50
Fluid temperature range °C -20 / +80
Fluid viscosity range cSt 10 ÷ 400
Fluid contamination degree according to ISO 4406:1999 class 20/18/15
Recommended viscosity cSt 25
Mass: DSP7-S, RK
DSP7-T*, SA*, SB*
DSC7
kg
8,6
8,0
6,6
SUBPLATE MOUNTING
ISO 4401-07
p max
350 bar
Q max 300 l/min
ISO 4401-07-07-0-05
(CETOP 4.2-4-07-350)
PERFORMANCES
(obtained with mineral oil of viscosity of 36 cSt at 50°C)
41 420/117 ED
2/12
DSP7
1 - IDENTIFICATION CODE FOR DSP7 SOLENOID VALVES
Drainage (see paragraph 9):
I = Internal
E = External
Control options (see paragraph 11):
C = Main spool stroke control
D = Main spool switching speed control
P08 = Subplate placed under solenoid valve with restrictor of Ø0.8 on port P
S2 = Distributor delivered with pilot solenoid valve with spool S2
Directional valve,
Solenoid controlled,
Pilot operated
Size:
ISO 4401-07
Spool type (see paragraph 2)
S* TA
SA* TB
SB* RK
Series: (the overall and mounting dimensions
remain unchanged from 20 to 29)
Seals:
N = NBR seals for mineral oil (standard)
V = FPM seals for special fluids
Piloting (see paragraph 9):
I = internal (not available for spools S2 - S4 - S7 - S8 - TA02 - TB02
RK02 - S*2 - S*4. If internal pilot is required, choose pilot type C)
C= internal piloting with backpressure valve
Z = internal piloting with 30 bar fixes adjustment pressure reducing
valve (see paragraph 8)
E = external
Manual override:
omit for override integrated in
the tube (standard)
CM = manual override, boot
protected (see paragraph 17)
S
P 7 20 / /
/
- / -
Power supply (see paragraph 10)
direct current
D12 = 12 V
D24 = 24 V
D48 = 48 V
D110 = 110 V
D220 = 220 V
D00 = valve without coils (see NOTE 1)
alternate current
A24 = 24 V - 50 Hz
A48 = 48 V - 50 Hz
A110 = 110 V - 50 Hz / 120 V - 60 Hz
A230 = 230 V - 50 Hz / 240 V - 60 Hz
A00 = valve without coils (see NOTE 1)
F110 = 110 V - 60 Hz
F220 = 220 V - 60 Hz
Option:
(omit for standard version)
H = high pressure version
pmax = 420 bar
D
Coil electrical connection
(see par. 15):
K1 = plug for connector type
EN 175301-803 (ex DIN 43650)
(standard)
K7 = plug DEUTSCH DT04-2P for male
connector type DEUTSCH DT06-2S
(available on D12 and D24 coils only)
Option:
/ W7 = Zinc-nickel
surface treatment
(see NOTE 2)
Omit if not required
NOTE 1: Coils locking ring and related OR are supplied together with valves.
NOTE 2: The standard valve is supplied with surface treatment of phosphating black.
The zinc-nickel finishing on the valve body (both main and pilot) makes the valve suitable to ensure a salt spray resistance up to 240 hours
(test operated according to UNI EN ISO 9227 standards and test evaluation operated according to UNI EN ISO 10289 standards).
For a salt spray resistance up to 600 hours refer to paragraph 1.1.
41 420/117 ED
3/12
DSP7
2 - SPOOLTYPE FOR DSP7
Type S*:
2 solenoids - 3 positions
with spring centring
Type TA:
1 solenoid side A
2 external positions
with return spring
Type TB:
1 solenoid side B
2 external positions
with return spring
Type RK:
2 solenoids - 2 positions
with mechanical retention
Type SA*:
1 solenoid side A
2 positions (central + external)
with spring centring
Type 23TA / 23TB
three-way valve - 1 solenoid - 2 external positions, return spring
Type SB*:
1 solenoid side B
2 positions (central + external)
with spring centring
Besides the diagrams shown, special versions are available: consult our technical dept. for their identification, feasibility and operating limits.
1.1 - High corrosion resistance version
This version, available for the basic valve (without option of par. 13) features the zinc-nickel coating on all exposed metal parts of the valve,
making it resistant to exposure to the salt spray for 600 hours (test performed according to UNI EN ISO 9227 and assessment test performed
according to UNI EN ISO 10289).
The coil are DC only and specific for this version, featuring a zinc-nickel surface treatment. The coil for DEUTSCH connector has a diode
inside. Electrical features at paragraph 10.2. The boot manual override (CM) is installed as standard in order to protect the solenoid tube.
Follow the identification code below to order it
DSP7....
/
Choices as in standard
identification code
Manual override, boot protected
DC power supply
D12 = 12 V D24 = 24 V
Coil electrical connection (see par. 15)
WK1 = plug for connector type EN 175301-803 (ex DIN 43650)
WK7D = plug DEUTSCH DT04-2P, for male connector type
DEUTSCH DT06-2S. Coil with diode.
/ CM / W7
41 420/117 ED
4/12
DSP7
3 - IDENTIFICATIONCODE AND SPOOLTYPE FOR DSC7 - HYDRAULIC OPERATED VALVE
Spool type (see paragraph 2 and below)
S* TA
SA* TB
SB* R
Seals:
N = NBR seals for mineral oil (standard)
V = FPM seals for special fluids
Series: (the overall and mounting dimensions
remain unchanged from 10 to 19)
Size: ISO 4401-07
D S C 7
10
-- /
External pilot (see par. 9)
External drain (see par. 9)
E
E
Spool type
The distributor is delivered with short-circuit subplate. The X and Y ports are used
for the hydraulic control of the valve.
4 - HYDRAULIC FLUIDS
Use mineral oil-based hydraulic fluids HL or HM type, according to ISO 6743-4. For these fluids, use NBR seals (code N). For fluids HFDR type
(phosphate esters) use FPM seals (code V).
For the use of other kinds of fluid such as HFA, HFB, HFC, please consult our technical department. Using fluids at temperatures higher than
80 °C causes a faster degradation of the fluid and of the seals characteristics.
The fluid must be preserved in its physical and chemical characteristics.
Directional valve, hydraulic controlled
pilot operated through X and Y ports.
Option: (omit for standard version)
H = high pressure version
pmax = 420 bar
Option:
/ W7 = Zinc-nickel surface
treatment (see NOTE)
Omit if not required
NOTE : The standard valve is supplied with surface treatment of phosphating black.
The zinc-nickel finishing makes the valve suitable to ensure a salt spray resistance up to 600 hours. (test operated according to
UNI EN ISO 9227 standards and test evaluation operated according to UNI EN ISO 10289 standards).
41 420/117 ED
5/12
DSP7
PRESSURE DROPS WITH VALVE IN DE-ENERGIZED POSITION
PRESSURE DROPS WITH VALVE ENERGIZED
5 - PRESSURE DROPS P-Q
(values obtained with viscosity 36 cSt at 50 °C)
FLOW DIRECTION
SPOOL TYPE P-A P-B A-T B-T
C
URVES ON GRAPH
S1, SA1, SB1 1 1 3 4
S2, SA2, SB2 1 1 4 4
S
3, SA3, SB3 1 1 4 4
S
4, SA4, SB4 2 2 4 5
S6 1 1 3 4
S7 1 1 4 4
S8 1 1 3 4
S
9 1 1 3 4
S
10 1 1 3 4
S11 1 1 3 4
S12 1 1 3 4
S20 1 1 3 4
S21 1 1 4 4
TA, TB 1 1 3 4
TA02, TB 02 1 1 4 4
RK 1 1 3 4
FLOW DIRECTION
SPOOL TYPE P-A P-B A-T B-T P-T
CURVES ON GRAPH
S2, SA2, SB2 6
S3, SA3, SB3 7 7
S4, SA4, SB4 7
S6 7
S7 8
S8 8
S10 7 7
S11 7
6 - SWITCHING TIMES
The values indicated refer to a solenoid valve working with piloting
pressure of 100 bar, with mineral oil at a temperature of 50°C, at
viscosity of 36 cSt and with PA and BT connections. The energizing
and de-energizing times are obtained at the pressure variation
which occurs on the lines.
TIMES (± 10%)
ENERGIZED  DE-ENERGIZED
[ms]
2 Pos. 3 Pos. 2 Pos. 3 Pos.
AC solenoid 45 30 45 30
DC solenoid 75 60 60 45
41 420/117 ED
6/12
DSP7
8 - PERFORMANCE CHARACTERISTICS
NOTE 1 minimum piloting pressure can be the lower range value at low flows rates, but with higher flow rates the higher value is needed.
NOTE 2 If the valve operates at higher pressures it is necessary to use the version with external pilot and reduced pressure. Otherwise, the
valve can be ordered with internal pilot and pressure reducing valve with 30 bar fixed adjustment (pilot type Z, see identification code)
7 - OPERATING LIMITS
The curves define the flow rate operating fields according to the valve pressure for the different spool types.
The values have been obtained according to ISO 6403 norm with solenoids at rated temperature and supplied with voltage equal to 90% of the
nominal voltage.
The values have been obtained with mineral oil, viscosity 36 cSt at 50 °C, and filtration ISO 4406:1999 class 18/16/13.
PRESSURES [bar] DSP7 DSP7H DSC7 DSC7H
Max pressure in P, A, B ports 350 420 350 420
Max pressure in T line with external drainage 250 350 250 350
Max pressure in T line with internal drainage
210 (DC)
160 (AC)
210 (DC)
160 (AC)
- -
Max pressure in Y line with external drainage
210 (DC)
160 (AC)
210 (DC)
160 (AC)
- -
Min piloting pressure NOTE 1 5 ÷ 12
Max piloting pressure NOTE 2 210 350 210 420
S
POOL
CURVE
P→A P→B
S
1,SA1,SB1
1 1
S2, SA2, SB2 1 1
S3, SA3, SB3 1 1
S4, SA4, SB4 2 2
S
6
1 1
S
7
2 2
S8 2 2
S9 1 1
S10 1 1
S
11
1 1
S12 1 1
S20 1 1
S21 1 1
S
POOL
CURVE
P→A P→B
T
A, TB
1 1
TA02, TB02 1 1
23TA, 23TB 1 1
RK 1 1
41 420/117 ED
7/12
DSP7
9 - PILOTING AND DRAINAGE
The DSP7 valves are available with piloting and drainage, both internal and external. The version with external drainage allows for a higher
back pressure on the outlet.
X: plug M6x8 for external pilot
Y: plug M6x8 for external drain
pilot always internal
Y: plug M6x8 for external drain
9.1 - Backpressure valve incorporated on line P
Valves DSP7 are available upon request with backpressure valve incorporated on line P. This is necessary to obtain the piloting pressure when
the control valve, in rest position, has the line P connected to the T port (spools S2, S4, S7, S8, S*2, S*4, TA02, TB02, RK02). The cracking
pressure is of 5 bar with a minimum flow rate of 15 l/min.
Add C to the identification code for this request (see paragraph 1).
In the C version the piloting is always internal.
The backpressure valve can be also delivered separately and it can be easily mounted on line P of the main control valve. Specify the code
0266577 to order the backpressure valve separately.
DSP7-C
The curve refers to the pressure drop (body part
only) with backpressure valve energized to which
the pressure drop of the reference spool must be
added. (see paragraph 5)
NOTE: the backpressure valve can’t be used as
check valve because it doesn’t assure the seal.
T
YPE OF VALVE
P
lug assembly
X Y
IE
INTERNAL PILOT AND
EXTERNAL DRAIN
NO YES
II
INTERNAL PILOT AND
INTERNAL DRAIN
NO NO
EE
EXTERNAL PILOT AND
EXTERNAL DRAIN
YES YES
EI
EXTERNAL PILOT AND
INTERNAL DRAIN
YES NO
41 420/117 ED
8/12
DSP7
10 - ELECTRICAL FEATURES
10.1 Solenoids
These are essentially made up of two parts: tube and coil. The tube
is threaded into the valve body and includes the armature that
moves immersed in oil, without wear. The inner part, in contact with
the oil in the return line, ensures heat dissipation.
The coil is fastened to the tube by a threaded ring, and can be
rotated 360°, to suit the available space.
NOTE: In order to further reduce the emissions, use of type H
connectors is recommended. These prevent voltage peaks on
opening of the coil supply electrical circuit (see data sheet 49 000).
10.2 - DC coils
In direct current energizing, current consumption stays at fairly constant values, essentially determined by Ohm’s law: V = R x I.
The WK1 and WK7D are coils specific for the high corrosion resistance version of the valve.
The WK7D coil includes a suppressor diode of pulses for protection from voltage peaks during switching. During the switching the diode
significantly reduces the energy released by the winding, by limiting the voltage to 31.4V in the D12 coil and to 58.9 V in the D24 coil.
Using connectors type "D" (see cat. 49 000) with embedded bridge rectifier it is possible to feed DC coils (starting from 48V voltage) with
alternating current (50 or 60 Hz), considering a reduction of the operating limits by approximately 5 ÷ 10%.
The table shows current and power consumption values for DC coils.
(values ±10%)
10.3 - AC coils
The table shows current and power consumption values at inrush and at holding, relevant to the different coil types for AC current.
Coils for alternating current (values ± 5%)
Protection from atmospheric agents IEC EN 60529
Connection IP 65 IP 67 IP 69 K
K1 EN 175301-803 x (*)
K7 DEUTSCH DT04 male x x x (*)
(*) The protection degree is guaranteed only with the connector
correctly connected and installed
SUPPLY VOLTAGE FLUCTUATION
± 10% Vnom
MAX SWITCH ON FREQUENCY
10.000 ins/hour
DUTY CYCLE
100%
ELECTROMAGNETIC COMPATIBILITY
(EMC) (NOTE)
In compliance with
2014/30/EU
LOW VOLTAGE
In compliance with
2014/35/EU
CLASS OF PROTECTION
Coil insulation (VDE 0580)
Impregnation: (DC valve)
(AC valve)
class H
class F
class H
Suffix
Nominal
Voltage
[V]
Freq.
[Hz]
Resistance
at 20°C
[Ohm] (±1%)
Current
consumption
at inrush
[A] (±5%)
Current
consumption
at holding
[A] (±5%)
Power
consumption
at inrush
(±5%) [VA]
Power
consumption
at holding
(±5%) [VA]
Coil
Code
A24 24
50
1,46 82192 48 1902830
A48 48 5,84 4,4 1,1 204 51 1902831
A110
110V-50Hz
120V-60Hz
50/60
32
1,84 0,46 192 48
1902832
1,56 0,39 188 47
A230
230V-50Hz
240V-60Hz
140
0,76 0,19 176 44
1902833
0,6 0,15 144 36
F110 110
60
26 1,6 0,4 176 44 1902834
F220 220 106 0,8 0,2 180 45 1902835
Nominal
voltage
[V]
Resistance
at 20°C
[Ω]
Current
consumption
[A]
Power
consumption
[W]
Coil code
K1 WK1 K7 WK7D
D12 12 4,4 2,72 32,7 1903080 1903050 1902940 1903400
D24 24 18,6 1,29 31 1903081 1903051 1902941 1903401
D48 48 78,6 0,61 29,5 1903083
D110 110 436 0,26 28,2 1903464
D220 220 1758 0,13 28,2 1903465
41 420/117 ED
9/12
DSP7
11 - OPTIONS
11.1 - Control of the main spool stroke: C
With the help of special side plugs, it is possible to introduce stroke controls in the
heads of the piloted valve so as to vary the maximum spool clearance opening.
This solution allows control of the flow rate from the pump to the actuator and from
the actuator to the outlet, obtaining a double adjustable control on the actuator.
Add the letter C to the identification code to request this device (see paragraph 1).
11.2 - Control of the main spool shifting speed: D
By placing a MERS type double flow control valve between the pilot solenoid valve
and the main distributor, the piloted flow rate can be controlled and therefore the
changeover smoothness can be varied.
Add the letter D to the identification code to request this device (see paragraph 1).
11.3 - Subplate with throttle on line P
It is possible to introduce a subplate with a restrictor of Ø0,8 on line P between the
pilot solenoid valve and the main distributor.
Add P08 to the identification code to request this option (see paragraph 1).
11.4 - Solenoid operated distributor with pilot valve in configuration S2
It is possible to deliver the solenoid operated distributor with pilot valve in
configuration S2 (all the ports at outlet). With this option the piloting is necessarily
external.
Add S2 to the identification code to request this option (see paragraph 1).
This configuration is used with external piloting in order to allow the unloading of the
piloting line when the solenoid operated valve is in rest position.
DSP7-S*/D
DSP7-S*/P08
DSP7-S*/C
41 420/117 ED
10/12
DSP7
12 - DSP7 OVERALLAND MOUNTINGDIMENSIONS FOR SOLENOID DISTRIBUTOR
dimensions in mm
DSP7-S
DSP7-RK
solenoid position
configuration TB/SB*
DSP7-TA
DSP7-SA*
DSP7-*/20*-Z*
1 Mounting surface with sealing rings
4 OR type 130 (22.22X2.62) - 90 Shore
2 OR type 2043 (10.82x1.78) - 90 Shore
2 Manual override
3 Coil removal space
4 Connector removal space
5 Electric connector to be ordered separately
(see cat. 49 000)
6 Reducing valve with fixed adjustment 30 bar
Fastening of single valve: 4 SHC screws ISO 4762 M10x60
2 SHC screws ISO 4762 M6x50
Tightening torque: M10x60: 40 Nm (A8.8) - 57 Nm (A10.9)
M6x50: 8 Nm (A8.8) - 12 Nm (A10.9)
Threads of mounting holes: M6x12; M10x18
NOTE: Use of fastening screws class A10.9 is recommended
for valves in version H (high pressure)
41 420/117 ED
11/12
DSP7
13 - DSC7 OVERALLAND MOUNTINGDIMENSIONS FOR HYDRAULIC DISTRIBUTOR DSC7
dimensions in mm
NOTE: Use of fastening screws class A10.9 is recommended
for valves in version H (high pressure)
17
114
1 Mounting surface with sealing rings:
4 OR type 130 (22.22X2.62) - 90 Shore
2 OR type 2043 (10.82x1.78) - 90 Shore
2 Short-circuit subplate
Fastening of single valve: 4 SHC screws ISO 4762 M10x60
2 SHC screws ISO 4762 M6x50
Tightening torque: M10x60: 40 Nm (A8.8) - 57 Nm (A10.9)
M6x50: 8 Nm (A8.8) - 12 Nm (A10.9)
Threads of mounting holes: M6x12; M10x18
14 - INSTALLATION
Configurations with centring and recall springs can be mounted in any position; type RK valves - without
springs and with mechanical detent - must be mounted with the longitudinal axis horizontal.
Valve fastening takes place by means of screws or tie rods, laying the valve on a lapped surface, with
values of planarity and smoothness that are equal to or better than those indicated in the drawing. If the
minimum values of planarity or smoothness are not met, fluid leakages between valve and mounting
surface can easily occur.
NOTE: Use of fastening screws class 10.9 is recommended for valves in version H (high pressure).
Surface quality
41 420/117 ED
12/12
DSP7
REPRODUCTION IS FORBIDDEN. THE COMPANY RESERVES THE RIGHT TO APPLY ANY MODIFICATIONS.
16 - ELECTRIC CONNECTORS
Solenoid valves are delivered without connectors. Connectors type EN 175301-803 (ex DIN 43650) for K1 and WK1 connections can be
ordered separately. See catalogue 49 000.
15 - ELECTRIC CONNECTIONS
connection for
DEUTSCH DT06-2S male
connector type
code K7
connection for
DEUTSCH DT06-2S male
connector - coil with diode
code WK7D (W7 version only)
connection for EN 175301-803
(ex DIN 43650) connector
code K1 (standard)
code WK1 (W7 version only)
18 - SUBPLATES
(see catalogue 51 000)
These plates are not suitable for high pressure valves DSP7H.
Type with rear ports PME07-AI6G
Type with side ports PME07-AL6G
P, T, A, B, port dimensions 1” BSP
X, Y; L port dimensions 1/4” BSP
17 - MANUAL OVERRIDE
Whenever the solenoid valve installation may involve exposure to atmospheric agents
or use in tropical climates, the manual override, boot protection is recommended.
Add the suffix CM to request this device (see paragraph 1).