41 420/117 ED
8/12
DSP7
10 - ELECTRICAL FEATURES
10.1 Solenoids
These are essentially made up of two parts: tube and coil. The tube
is threaded into the valve body and includes the armature that
moves immersed in oil, without wear. The inner part, in contact with
the oil in the return line, ensures heat dissipation.
The coil is fastened to the tube by a threaded ring, and can be
rotated 360°, to suit the available space.
NOTE: In order to further reduce the emissions, use of type H
connectors is recommended. These prevent voltage peaks on
opening of the coil supply electrical circuit (see data sheet 49 000).
10.2 - DC coils
In direct current energizing, current consumption stays at fairly constant values, essentially determined by Ohm’s law: V = R x I.
The WK1 and WK7D are coils specific for the high corrosion resistance version of the valve.
The WK7D coil includes a suppressor diode of pulses for protection from voltage peaks during switching. During the switching the diode
significantly reduces the energy released by the winding, by limiting the voltage to 31.4V in the D12 coil and to 58.9 V in the D24 coil.
Using connectors type "D" (see cat. 49 000) with embedded bridge rectifier it is possible to feed DC coils (starting from 48V voltage) with
alternating current (50 or 60 Hz), considering a reduction of the operating limits by approximately 5 ÷ 10%.
The table shows current and power consumption values for DC coils.
(values ±10%)
10.3 - AC coils
The table shows current and power consumption values at inrush and at holding, relevant to the different coil types for AC current.
Coils for alternating current (values ± 5%)
Protection from atmospheric agents IEC EN 60529
Connection IP 65 IP 67 IP 69 K
K1 EN 175301-803 x (*)
K7 DEUTSCH DT04 male x x x (*)
(*) The protection degree is guaranteed only with the connector
correctly connected and installed
SUPPLY VOLTAGE FLUCTUATION
± 10% Vnom
MAX SWITCH ON FREQUENCY
10.000 ins/hour
DUTY CYCLE
100%
ELECTROMAGNETIC COMPATIBILITY
(EMC) (NOTE)
In compliance with
2014/30/EU
LOW VOLTAGE
In compliance with
2014/35/EU
CLASS OF PROTECTION
Coil insulation (VDE 0580)
Impregnation: (DC valve)
(AC valve)
class H
class F
class H
Suffix
Nominal
Voltage
[V]
Freq.
[Hz]
Resistance
at 20°C
[Ohm] (±1%)
Current
consumption
at inrush
[A] (±5%)
Current
consumption
at holding
[A] (±5%)
Power
consumption
at inrush
(±5%) [VA]
Power
consumption
at holding
(±5%) [VA]
Coil
Code
A24 24
50
1,46 82192 48 1902830
A48 48 5,84 4,4 1,1 204 51 1902831
A110
110V-50Hz
120V-60Hz
50/60
32
1,84 0,46 192 48
1902832
1,56 0,39 188 47
A230
230V-50Hz
240V-60Hz
140
0,76 0,19 176 44
1902833
0,6 0,15 144 36
F110 110
60
26 1,6 0,4 176 44 1902834
F220 220 106 0,8 0,2 180 45 1902835
Nominal
voltage
[V]
Resistance
at 20°C
[Ω]
Current
consumption
[A]
Power
consumption
[W]
Coil code
K1 WK1 K7 WK7D
D12 12 4,4 2,72 32,7 1903080 1903050 1902940 1903400
D24 24 18,6 1,29 31 1903081 1903051 1902941 1903401
D48 48 78,6 0,61 29,5 1903083
D110 110 436 0,26 28,2 1903464
D220 220 1758 0,13 28,2 1903465