21 310/112 ED
1/4
RQM
*
-P
SOLENOID OPERATED PRESSURE
RELIEF VALVES WITH UNLOADING
AND PRESSURE SELECTION
SERIES 60
21 310/112 ED
OPERATING PRINCIPLE
— The RQM*-P valves are pressure relief valves
available in three nominal sizes for flow up to 500
l/min.
— They are available in ISO 6264 (CETOP RP 121H)
subplate mounting version.
Available in five versions that allow, by means of a
solenoid valve, unloading of the total flow and
selection up to three pressure values (see table 2
Versions).
— The adjustment of the second and third pressure
values is obtained by a pressure relief valve placed
between the main stage and the solenoid valve.
It is supplied with an hexagonal head adjustment
screw. Upon request, it can be equipped with a
SICBLOC adjustment knob on the main pressure
control.
NOTE: for the solenoid valve DS3 characteristics see catalogue 41 150
SUBPLATE MOUNTING
RQM3-P ISO 6264-06 (CETOP R06)
RQM5-P ISO 6264-08 (CETOP R08)
RQM7-P ISO 6264-10 (CETOP R10)
RQM3-P RQM5-P RQM7-P
Maximum operating pressure bar 350
Maximum flow rate l/min 200 400 500
Ambient temperature range °C -20 / +50
Fluid temperature range °C -20 / +80
Fluid viscosity range cSt 10 ÷ 400
Fluid contamination degree According to ISO 4406:1999 class 20/18/15
Recommended viscosity cSt 25
PERFORMANCES (measured with mineral oil of viscosity 36 cSt at 50°C)
21 310/112 ED
2/4
RQM*-P
SERIES 60
1 - IDENTIFICATION CODE
Series No. (the overall and mounting dimensions
remain unchanged from 60 to 69)
Size: 3 = ISO 6264-06 (CETOP R06)
5 = ISO 6264-08 (CETOP R08)
7 = ISO 6264-10 (CETOP R10)
pilot operated
pressure relief
valve
solenoid valve
for unloading / pressure
selection
M = adjustment with SICBLOC knob
available only on the main pressure control
(Omit for adjustment with hexagonal head screw)
Subplate mounting
Pressure adjustment range:
3 = up to 70 bar 6 = up to 350 bar
5 = up to 210 bar
Versions: A
B see description
C in hydraulic symbols
D table
G
R Q M - P / / / 60
3 - CHARACTERISTIC CURVES (values obtained with viscosity of 36 cSt at 50°C)
2 - VERSIONS
ADJUSTMENT MINIMUM CONTROLLED PRESSURE
DC power supply
D12 = 12 V
D24 = 24 V
D48 = 48 V
D110 = 110 V
D220 = 220 V
D00 = valve without coils (see note)
AC power supply
A24 = 24 V - 50 Hz
A48 = 48 V - 50 Hz
A110 = 110 V - 50 Hz / 120 V - 60 Hz
A230 = 230 V - 50 Hz / 240 V - 60 Hz
A00 = valve without coils (see note)
F110 = 110 V - 60 Hz
F220 = 220 V - 60 Hz
Coil electrical connection:
plug for connector type
DIN 43650 (standard)
Seals:
N = NBR seals for mineral oil (standard)
V = FPM seals for special fluids
- K1
/
Manual override: omit
for override integrated
in the tube (standard)
CM = manual override,
boot protected
NOTE: The locking rings of the coils and the relevant O-Rings are supplied together with valves
@
1 pressure setting
and unloading with
de-energized
solenoid
1 pressure setting
and unloading with
energized solenoid
2 pressure settings
The highest setting is
reached with
energized solenoid
2 pressure settings
and unloading with
de-energized
solenoids
3 pressure settings
The highest setting is
reached with
de-energized solenoids
RQM*-P * /A RQM*-P * / B RQM*-P * / C RQM*-P * / D RQM*-P * / G
21 310/112 ED
3/4
RQM*-P
SERIES 60
5 - OVERALL AND MOUNTING DIMENSIONS
dimensions in mm
RQM*-P/A RQM*-P/C
RQM*-P/B
RQM*-P/D RQM*-P/G
4 - HYDRAULIC FLUIDS
Use mineral oil-based hydraulic fluids HL or HM type, according to ISO 6743-4. For these fluids, use NBR seals (code N). For fluids HFDR type
(phosphate esters) use FPM seals (code V). For the use of other kinds of fluid such as HFA, HFB, HFC, please consult our technical
department. Using fluids at temperatures higher than 80 °C causes a faster degradation of the fluid and of the seals characteristics.
The fluid must be preserved in its physical and chemical characteristics.
A B C D E F G H
RQM3-P 186 126 22 179 164 226 223 44
RQM5-P 196 126 14 170 164 236 222 52
RQM7-P 206 126 25 180 164 246 221 41
1 Mounting surface
For fastening bolts
and sealing rings see
paragraph 10
2 Hexagonal head main
pressure adjustment
screw:
Spanner 13
Clockwise rotation to
increase pressure
3 Second value
pressure adjustment
valve.
Countersunk hex
adjustment screw:
Spanner 5
Clockwise rotation to
increase pressure
4 ISO 4401-03
(CETOP 03) solenoid
valve for pressure
selection / unloading
5 Pressure gauge port
3/8” BSP
21 310/112 ED
4/4
DUPLOMATIC OLEODINAMICA S.p.A.
20015 PARABIAGO (MI)  Via M. Re Depaolini 24
Tel. +39 0331.895.111
Fax +39 0331.895.339
www.duplomatic.com  e-mail: sales.exp@duplomatic.com
RQM*-P
SERIES 60
REPRODUCTION IS FORBIDDEN. THE COMPANY RESERVES THE RIGHT TO APPLY ANY MODIFICATIONS.
6 - MOUNTING SURFACES
11 - SUBPLATES
(see catalogue 51 000)
7 - ADJUSTMENT KNOB
The valves can be equipped with a SICBLOC adjustment knob, only on the main pressure regulation.
To operate it, push and rotate at the same time.
To request this option, add: /M (see paragraph 1).
8 - ELECTRIC CONNECTORS
The solenoid valves are never supplied with connector. Connectors must be ordered separately. For the
identification of the connector type to be ordered, please see catalogue 49 000.
9 - MANUAL OVERRIDE, BOOT PROTECTED: CM
Whenever the solenoid valve installation may involve exposure to atmospheric agents or utilization in tropical climates, use of the manual
override boot protected is recommended.
Add the suffix CM to request this device (see paragraph 1). For overall dimensions see catalogue 41 150.
10 - FASTENING BOLTS AND SEALING RINGS
TP
M12
G
Ø14.7 (max)
X
22.1
26.9
Ø7.5Ø4.8
53.8
53.8
47.5
M16
66.7
55.6
11.1
33.4
PT
Ø7.5
G
23.8
X
70
35
Ø6.3
Ø23.4 (max)
Ø32 (max)
88.9
12.7
44.5
76.2
TP
X
M18
G
31.8
41.3
82.6
Ø6.3 Ø7.5
RQM3 RQM5 RQM7
ISO 6264-06-09-*-97 (CETOP 4.4.2-2-R06-350) ISO 6264-08-13-*-97 (CETOP 4.4.2-2-R08-350) ISO 6264-10-17-*-97 (CETOP 4.4.2-2-R10-350)
RQM3-P RQM5-P RQR7-P
Type
PMRQ3-AI4G
rear ports
PMRQ5-AI5G
rear ports
PMRQ7-AI7G
rear ports
P, T, U ports dimension
P: 1/2” BSP
T: 3/4” BSP
1” BSP 1” 1/4 BSP
X port dimension 1/4” BSP 1/4” BSP 1/4” BSP
RQM3-P RQM5-P RQM7-P
Fastening (4 SHC bolts ISO 4762) M12 x 40 M16 x 50
M18 x 60
Torque 69 Nm 170 Nm 235 Nm
Sealing rings
N. 2 OR type 123 (17.86x2.62)
90 Shore
N. 1 OR type 109 (9.13x2.62)
90 Shore
N. 2 OR type 3118 (29.82x2.62)
90 Shore
N. 1 OR type 109 (9.13x2.62)
90 Shore
N. 2 OR type 4137 (34.52x3.53)
90 Shore
N. 1 OR type 109 (9.13x2.62)