21 100/117 ED
1/2
21 100/117 ED
CR
DIRECT OPERATED
PRESSURE CONTROL VALVE
SERIES 22
PERFORMANCES (measured with mineral oil of viscosity 36 cSt at 50°C) HYDRAULIC SYMBOL
OPERATING PRINCIPLE
SEAT DIMENSIONS: D-10E
The CR valve is a direct operated pressure control valve
cartridge type that can be used in blocks or panels with
type D-10B seat.
It is normally used to control the maximum pressure in the
hydraulic circuits or as a limiting device for pressure peaks
generated during hydraulic actuator movement variation.
It is available in five different pressure control ranges up to
350 bar.
The circuit pressure acts on the shutter which is directly
loaded by a spring on the opposite side. Once the set
pressure is reached, the shutter opens, and discharges the
excess flow in port T connected directly to the reservoir.
The pressure can be adjusted by a screw, usually supplied
as the countersunk hex type, equipped with locking nut and
maximum adjustment limiter.
CARTRIDGE TYPE
p max
350 bar
Q max 50 l/min
Max working pressure bar 350
Minimum controlled pressure and pressure drop see diagram
Maximum flow rate l/min 50
Ambient temperature range °C -20 / +60
Fluid temperature range °C -20 / +80
Fluid viscosity range cSt 10 ÷ 400
Fluid contamination degree
According to
ISO 4406:1999 class 20/18/15
Recommended viscosity cSt 25
Mass kg 0,16
Surface treatment: electrolytic zinc covering
Fe / Zn8 /B
ISO 2081
21 100/117 ED
2/2
CR
SERIES 22
REPRODUCTION IS FORBIDDEN. THE COMPANY RESERVES THE RIGHT TO APPLY ANY MODIFICATIONS.
1 - IDENTIFICATION CODE
2 - CHARACTERISTIC CURVES (values obtained with viscosity of 36 cSt at 50°C)
4 - OVERALL AND MOUNTING DIMENSIONS
dimensions in mm
A
DJUSTMENT
M
INIMUM CONTROLLED PRESSURE
Seals:
N = NBR seals for mineral oils (standard)
V = FPM seals for special fluids
Series No. (the overall and mounting
dimensions remain unchanged from 20 to 29)
Pressure adjustment range:
2 = up to 25 bar
3 = up to 70 bar
4 = up to 140 bar
5 = up to 210 bar
6 = up to 350 bar
Direct operated pressure
control valve
Cartridge type
K = Adjustment knob
(omit for adjustment with countersunk
hex screw - standard)
C R / 22 /
P
-T pressure drops
with screw set at
minimum pressure
c
ontrol
3 - HYDRAULIC FLUIDS
Use mineral oil-based hydraulic fluids HL or HM type, according to ISO 6743-4. For these fluids, use NBR seals (code N). For fluids HFDR type
(phosphate esters) use FPM seals (code V). For the use of other kinds of fluid such as HFA, HFB, HFC, please consult our technical
department. Using fluids at temperatures higher than 80 °C causes a faster degradation of the fluid and of the seals characteristics.
The fluid must be preserved in its physical and chemical characteristics.
1 OR type 2056 (14.00x1.78)
90 Shore
2 OR type 3062 (15.54x2.62)
90 Shore
3 Hexagonal: spanner 22
Tightening torque 45 ÷ 50 Nm
4 Locking nut: spanner 19
5 Countersunk hex adjustment screw:
spanner 6 (standard)
Clockwise rotation to increase
pressure
6 Maximum screw stroke
7 Adjustment knob: K
8 Locking ring