DSV2-100-2NCP
Normally-Closed, Two-Way, Two-Position,
Pilot-Operated Solenoid Valve
PRESSURE DROP VS. FLOW
CHECKMOTION
CONTROL
FLOW
CONTROL
S
ERIES 10
1.03.1
DESCRIPTION
A cartridge valve designed with positive shut off to be used in load
holding applications.
OPERATION
When de-energized, the DSV2-100-2NCP acts as a check valve, allowing
flow from to , while blocking flow from to .
When energized, the poppet lifts to open the to flow path.
Operation of Manual Override Option: To override, push button in,
twist counterclockwise and release. In this position, valve will remain
open in a detented condition.
To return to normal operation, push button in, twist clockwise and
release. Override will be detented in this position.
FEATURES and BENEFITS
Continuous-duty solenoid.
Hardened poppet and plunger for long life and low leakage.
Efficient wet-armature construction.
Cartridges are voltage interchangeable.
Optional coil voltages and terminations.
Filter screen standard.
Manual override option.
Industry common cavity.
Compact size.
SPECIFICATIONS
Operating Pressure: 3000 PSI (207 Bar)
Flow: See PRESSURE DROP VS. FLOW graph.
Internal Leakage: 5 drops/min. max. at 3000 PSI (207 Bar)
Temperature: -30° F to +250° F (-35°C to +120° C)
Coil Rating: Continuous from 85% to 110% of rated voltage.
Current Draw: 12 VDC is 1.8 amps.
Minimum Pull-In Voltage: 85% of rated voltage at 3000 PSI (207 Bar)
Response Time: 80% of final change of state with 100% voltage
supplied at 100% of nominal flow rating.
Pull-In: 12 VDC 100 m. sec. Drop-Out: 12 VDC 180 m. sec.
Recommended Filtration: Critical Application-ISO 17/15/13
Non-Critical Application-ISO 20/18/14
Fluids: Mineral-based fluids. For other fluid compatibility consult factory.
Cavity/Cavity Tool: 100-2, see page 11.10.2
Body Material: Anodized 6061T6 aluminum
alloy rated at 3000 PSI (207 Bar).
USASI
ISO
10186-24 02/08
2008 Deltrol Catalog:Deltrol2004Run8 2/26/08 2:06 PM Page 10
DSV2-100-2NCP
Normally-Closed, Two-Way, Two-Position,
Pilot-Operated Solenoid Valve
1.03.2
INSTALLATION DIMENSIONS
( ) Parentheses = Millimeters
Omit coil for cartridge only with nut.
Other porting and coil options available consult factory.
SOLENOID
TECHNICAL
DATA
SERIES 10
RELIEF PRESSURE
CONTROL
SEQUENCE
SHUTTLE
DIRECTIONAL
VALVES
ACCESSORIES
CHECK
MOTION
CONTROL
FLOW
CONTROL
DSV2 - 100 - 2 NC P - * - * - * * * - **
SOLENOID
VALVE
CAVITY/SEAL
FLOW PATH
NORMALLY CLOSED
POPPET
SEALS
N = Buna N
V = Viton
D = DC
A = AC
PORTING
2N = 1/4 PTF
3N = 3/8 PTF
6T = SAE 6
8T = SAE 8
Omit for Cartridge Only
COIL CONNECTION
D = Double Lead
S = Single Lead
H = Hirschmann
®
C = Conduit
B = Double Spade
E = Single Stud
M = Manual Override
(Omit for standard)
HOW TO ORDER
VOLTAGE
1 = 12 Volt
2 = 24 Volt
5 = 120 Volt
6 = 240 Volt
9 = 20 Volt
10 = 10 Volt
2008 Deltrol Catalog:Deltrol2004Run8 2/26/08 2:06 PM Page 11