DSV-080-2NCP
Normally-Closed, Two-Way, Two-Position,
Pilot-Operated Solenoid Valve
CHECKMOTION
CONTROL
FLOW
CONTROL
S
ERIES 8
1.01.1
USASI
ISO
PRESSURE DROP psi (bar)
FLOW gpm (L/min.)
5.0
(18.9)
4.0
(15.1)
3.0
(11.4)
2.0
(7.6)
1.0
(3.8)
0
125 (8.6)
100 (6.9)
75 (5.2)
50 (3.4)
25 (1.7)
0
PRESSURE DROP VS. FLOW
DESCRIPTION
A cartridge valve designed with positive shut off to be used in load
holding applications.
OPERATION
When de-energized, the DSV-080-2NCP acts as a check valve,
allowing flow from to , while blocking flow from to .
When energized, the poppet lifts to open the to flow path.
Operation of Manual Override Option: To override, push button in, twist
counterclockwise and release. In this position, the valve will remain open.
To return to normal operation, push button in, twist clockwise and release.
Override will be detented in this position. Note: Pull only to override and
release to return option available. See page 1.01.3
FEATURES and BENEFITS
4000 PSI (276 Bar) rating.
Continuous-duty solenoid.
Hardened poppet and plunger for long life and low leakage.
Efficient wet-armature construction.
Cartridges are voltage interchangeable.
Optional coil voltages and terminations.
Filter screen standard.
Low leak option available.
Manual override option.
Industry common cavity.
Compact size.
SPECIFICATIONS
Operating Pressure: 4000 PSI (276 Bar)
Flow: See PRESSURE DROP VS. FLOW graph
Internal Leakage: 5 drops/min. max. at 4000 PSI (276 Bar)
Low leakage available-
Less than 2 drops/min. max. at 4000 PSI (276 Bar)
Temperature: -30° F to +250° F (-35°C to +120° C)
Coil Rating: Continuous from 85% to 110% of rated voltage.
Current Draw: 12 VDC is 1.3 amps.
Minimum Pull-In Voltage: 85% of rated voltage at 4000 PSI (276 Bar)
Response Time: 80% of final change of state with 100% voltage
supplied at 100% of nominal flow rating.
Pull-In: 12 VDC 16 m. sec. Drop-Out: 12 VDC 18 m. sec.
Recommended Filtration: Critical Application-ISO 17/15/13
Non-Critical Application-ISO 20/18/14
Fluids: Mineral-based fluids. For other fluid compatibility consult factory.
Cavity/Cavity Tool: 080-2, see page 11.08.2
Body Material: Anodized 6061T6 aluminum
alloy rated at 3000 PSI (207 Bar).
10143-42 02/08
2008 Deltrol Catalog:Deltrol2004Run8 2/26/08 2:06 PM Page 6
DSV-080-2NCP
Normally-Closed, Two-Way, Two-Position,
Pilot-Operated Solenoid Valve
1.01.2
INSTALLATION DIMENSIONS
( ) Parentheses = Millimeters
Omit coil for cartridge only with nut.
Other porting and coil options available consult factory.
SOLENOID
TECHNICAL
DATA
SERIES 8
RELIEF PRESSURE
CONTROL
SEQUENCE
SHUTTLE
DIRECTIONAL
VALVES
ACCESSORIES
CHECK
MOTION
CONTROL
FLOW
CONTROL
HOW TO ORDER
.88 (22.4) HEX.
TORQUE 20 FT.-LBS.
(27.1 Nm) MAX.
MANUAL
OVERRIDE
OPTION
FILTER
250 NOM. MICRON
(EFFECTIVE FROM
TO ONLY)
.75 (19.0) HEX.
TORQUE 40 IN.-LBS.
(4.5 Nm) MAX.
1.08
(27.4)
.19
(4.8)
OPEN
2.60
(66.0)
1.88
(47.8)
1.13
(28.7)
1.25
(31.8)
1.63
(41.4)
.13
(3.3)
.28 TYP.
(7.1)
1.50
(38.1)
4.60
(116.8)
3.88
(98.6)
.19
(4.8)
OPEN
.59
(15.0)
2.00
(50.8)
.56
(14.2)
2.00
(50.8)
DSV - 080 - 2 NC P - * - * * - * * * * - **
SOLENOID
VALVE
CAVITY/SEAL
FLOW PATH
NORMALLY CLOSED
POPPET
SEALS
N = Buna N
V = Viton
M = Manual Override
(Omit for standard)
See page 1.01.3 for additional options.
L = Low Leak Option
(Omit for standard)
D = DC
A = AC
PORTING
2N = 1/4 PTF
3N = 3/8 PTF
4T = SAE 4
6T = SAE 6
Omit for Cartridge Only
COIL CONNECTION
DS = Double Lead
SS = Single Lead
H = Hirschmann
®
CS = Conduit
BS = Double Spade
ES = Single Stud
US = Deutsch
VOLTAGE
1 = 12 Volt
2 = 24 Volt
5 = 120 Volt
6 = 240 Volt
9 = 20 Volt
10 = 10 Volt
2008 Deltrol Catalog:Deltrol2004Run8 2/26/08 2:06 PM Page 7