SOLENOID
RELIEF
PRESSURE
CONTROL
SEQUENCE
SHUTTLE
DIRECTIONAL
VALVES
TECHNICAL
DATA
ACCESSORIES
DSV-080-2NCP
Normally-Closed, Two-Way, Two-Position,
Pilot-Operated Solenoid Valve
CHECKMOTION
CONTROL
FLOW
CONTROL
S
ERIES 8
1.01.1
PRESSURE DROP psi (bar)
FLOW gpm (L/min.)
5.0
(18.9)
4.0
(15.1)
3.0
(11.4)
2.0
(7.6)
1.0
(3.8)
0
125 (8.6)
100 (6.9)
75 (5.2)
50 (3.4)
25 (1.7)
0
➁
➀
➀ ➁
PRESSURE DROP VS. FLOW
DESCRIPTION
A cartridge valve designed with positive shut off to be used in load
holding applications.
OPERATION
When de-energized, the DSV-080-2NCP acts as a check valve,
allowing flow from ➀ to ➁, while blocking flow from ➁ to ➀.
When energized, the poppet lifts to open the ➁ to ➀ flow path.
Operation of Manual Override Option: To override, push button in, twist
counterclockwise and release. In this position, the valve will remain open.
To return to normal operation, push button in, twist clockwise and release.
Override will be detented in this position. Note: Pull only to override and
release to return option available. See page 1.01.3
FEATURES and BENEFITS
• 4000 PSI (276 Bar) rating.
• Continuous-duty solenoid.
• Hardened poppet and plunger for long life and low leakage.
• Efficient wet-armature construction.
• Cartridges are voltage interchangeable.
• Optional coil voltages and terminations.
• Filter screen standard.
• Low leak option available.
• Manual override option.
• Industry common cavity.
• Compact size.
SPECIFICATIONS
Operating Pressure: 4000 PSI (276 Bar)
Flow: See PRESSURE DROP VS. FLOW graph
Internal Leakage: 5 drops/min. max. at 4000 PSI (276 Bar)
Low leakage available-
Less than 2 drops/min. max. at 4000 PSI (276 Bar)
Temperature: -30° F to +250° F (-35°C to +120° C)
Coil Rating: Continuous from 85% to 110% of rated voltage.
Current Draw: 12 VDC is 1.3 amps.
Minimum Pull-In Voltage: 85% of rated voltage at 4000 PSI (276 Bar)
Response Time: 80% of final change of state with 100% voltage
supplied at 100% of nominal flow rating.
Pull-In: 12 VDC 16 m. sec. Drop-Out: 12 VDC 18 m. sec.
Recommended Filtration: Critical Application-ISO 17/15/13
Non-Critical Application-ISO 20/18/14
Fluids: Mineral-based fluids. For other fluid compatibility consult factory.
Cavity/Cavity Tool: 080-2, see page 11.08.2
Body Material: Anodized 6061T6 aluminum
alloy rated at 3000 PSI (207 Bar).
10143-42 02/08
2008 Deltrol Catalog:Deltrol2004Run8 2/26/08 2:06 PM Page 6