MECHANICAL FLOW CONTROLS
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526
mail: delta@delta-power.com • www.delta-power.com
WARNING: the specications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specic application should not be undertaken
without independent study, evaluation, and testing for suitability.
W 51 / 12-2022
SN-FDA FLOW DIVIDER / COMBINER VALVE, SPOOL TYPE
DESCRIPTION
16 size, 1 5/16-12 thread “Super Series,” spool-type ow divider/combiner valve.
OPERATION
In the dividing mode, the SN-FDA will divert input ow from port (2) to ports (3) and (1), based on the ratio
specied, regardless of operating pressure. The SN-FDA will combine input ows from ports (3) and (1), to port
(2) by same ratio. Should circuit operation result in a blockage of either (3) or (1), the opposite port may also close
under certain conditions. Should this potential exist, consult the factory.
FEATURES
• Hardened parts for long life.
• Industry common cavity.
0
100
200
0
300
5 10 15 20 25 30
Pressure Drop (PSI)
0
Flow (GPM)
5
10
15
20
0 25 50 75 100
Pressure Drop (bar)
Flow (LPM)
15 25 30
VALVE SPECIFICATIONS
Nominal Flow 40 GPM (151 LPM)
Accuracy on Flow Splits ±10% of Max Rated Inlet Flow
Maximum Operating Pressure 3500 PSI (241 bar)
Viscosity Range 36 to 3000 SSU (3 to 647 cSt)
Filtration ISO 18/16/13
Media Operating Temp. Range -40° to 250°F (-40° to 120°C)
Weight .95 lbs (.43 kg)
Operating Fluid Media General Purpose Hydraulic Fluid
Cartridge Torque Requirements 90 ft-lbs (122 Nm)
Cavity SUPER 4W
Cavity Form Tool (Finishing) 40500019
Seal Kit 21191413
Actual Test Data (Cartridge Only)
PERFORMANCE
HYDRAULIC SYMBOL
DO NOT EXCEED MAXIMUM FLOW PER
MODEL.