MECHANICAL PRESSURE CONTROLS
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526
mail: delta@delta-power.com • www.delta-power.com
WARNING: the specications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specic application should not be undertaken
without independent study, evaluation, and testing for suitability.
W 51 / 12-2022
SJ-RVR PILOT OPERATED RELIEF VALVE, WITH REVERSE FLOW
DESCRIPTION
16 size, 1 5/16-12 thread, “SIXTEEN” series, pilot operated relief valve with reverse ow.
OPERATION
The SJ-RVR blocks ow from (2) to (1) until sufcient pressure is present at (2) to force the pilot stage off its seat,
allowing the main stage spool to shift, opening (2) to (1). The relief ow path is from (2) to (1). Reverse ow, from
(1) to (2), occurs when the pressure at (1) is at least 30 PSI (2.1 bar) higher then at port (2). The Cartridge offers
smooth transition in response to load changes in common hydraulic circuits.
FEATURES
• Hardened parts for long life.
• Industry common cavity.
VALVE SPECIFICATIONS
Nominal Flow 40 GPM (151 LPM)
Rated Operating Pressure 3500 PSI (241 bar)
Viscosity Range 36 to 3000 SSU (3 to 647 cSt)
Filtration ISO 18/16/13
Media Operating Temp. Range -40° to 250°F (-40° to 120°C)
Weight 1.13 lbs (.51 kg)
Operating Fluid Media General Purpose Hydraulic Fluid
Cartridge Torque Requirements 90 ft-lbs (122 Nm)
Cavity SIXTEEN 2W
Cavity Form Tool (Finishing) 40500017
Seal Kit 21191400
0
500
1000
1500
2000
2500
3000
0 5
3500
10 15 20 25 30 35
0
50
100
150
0
200
25 50
Pressure Drop (PSI)
75 100 125
Tank PSI
Pressure Drop (bar)
Pressure Drop (bar)
Inlet PSI
0
500
1000
Standard Body
1500
2000
0 5
2500
10 15 20 25 30
Flow (GPM)
0
50
100
0
150
25 50 75
Pressure Drop (PSI)
100 125
Flow (LPM)
Standard Body
Flow (GPM)
Flow (LPM)
Port 2 to 1 Port 2 to 1 Port 1 to 2
HYDRAULIC SYMBOL
PERFORMANCE
Actual Test Data (Cartridge Only)