MECHANICAL PRESSURE CONTROLS
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526
mail: delta@delta-power.com • www.delta-power.com
WARNING: the specications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specic application should not be undertaken
without independent study, evaluation, and testing for suitability.
W 51 / 12-2022
PB-RVA DIRECT ACTING RELIEF VALVE
HYDRAULIC SYMBOL
PERFORMANCE VALVE SPECIFICATIONS
DESCRIPTION
8 size, 3/4-16 thread, “Power” series, direct acting relief valve.
OPERATION
The PB-RVA blocks ow from (2) to (1) until sufcient pressure is present at (2) to force the poppet to open and
allow metered ow from (2) to (1). The cartridge offers smooth transition in response to load changes in common
hydraulic circuits.
FEATURES
• Hardened parts for long life.
• Industry common cavity.
Nominal Flow 6 GPM (23 LPM)
Rated Operating Pressure 3500 PSI (241 bar)
Viscosity Range 36 to 3000 SSU (3 to 647 cSt)
Filtration ISO 18/16/13
Media Operating Temp. Range -40° to 250°F (-40° to 120°C)
Weight .30 lbs (.14 kg)
Operating Fluid Media General Purpose Hydraulic Fluid
Cartridge Torque Requirements 25 ft-lbs (34 Nm)
Cavity POWER 2W
Cavity Form Tool (Finishing) 40500005
Seal Kit 21191100
Actual Test Data (Cartridge Only)
0
500
1000
1500
2000
2500
3000
3500
4000
4500
0 2 4 6 8 10
Pressure Drop (PSI)
0
Flow (GPM)
50
100
150
200
250
300
0 5 10 15 20 25 30 35
Pressure Drop (bar)
Flow (LPM)
Port 2 to 1 Port 2 to 1 Port 2 to 1
1
2
Pressure at port (1) must not exceed 2500 PSI.