MECHANICAL FLOW CONTROLS
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526
mail: delta@delta-power.com • www.delta-power.com
WARNING: the specications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specic application should not be undertaken
without independent study, evaluation, and testing for suitability.
W 51 / 12-2022
MA-FCA ADJUSTABLE FLOW CONTROL VALVE, PRESSURE COMPENSATED
DESCRIPTION
7 size, 5/8-18 thread, “Mini” series, pressure compensated, ow control valve.
OPERATION
The cartridge maintains a constant ow rate out of (1) regardless of load pressure changes in the circuit
downstream of (1). The adjustable control differential spring load can be set to customer ow specication (see
options for ranges). The valve begins to respond to load changes when the ow through the valve creates a
pressure differential from (2) to (1) greater than 200 PSI with accurate ow maintenance from 200 to 3000 PSI
(14 to 207 bar). Reverse ow (1) to (2) returns through the control orice and is non-compensated. The regulated
ow increases from low to high with clockwise rotation of the knob.
FEATURES
Hardened parts for long life.
Industry common cavity.
Fine low-torque adjustment.
0
1
2
0 500 20001000 1500 2500 3000
Pressure Drop (PSI)
0
5
0 50 100 150 200
Flow (GPM)
(bar)Pressure Drop (bar)Pressure Drop
Flow (LPM)
Port 2 to 1 Port 2 to 1
0
1
2
3
4
0 500 20001000 1500 2500 3000
Pressure Drop (PSI)
0
5
10
15
0 50
Flow (GPM)
100 150 200
Flow (LPM)
Port 2 to 1 Port 2 to 1
VALVE SPECIFICATIONS
Nominal Flow 3 GPM (11 LPM)
Rated Operating Pressure 3000 PSI (207 bar)
Viscosity Range 36 to 3000 SSU (3 to 647 cSt)
Filtration ISO 18/16/13
Media Operating Temp. Range -40° to 250°F (-40° to 120°C)
Weight .29 lbs (.13 kg)
Operating Fluid Media General Purpose Hydraulic Fluid
Cartridge Torque Requirements 15 ft-lbs (20.3 Nm)
Cavity MINI 2W
Cavity Form Tool (Finishing) 40500003
Seal Kit 21191000
Actual Test Data (Cartridge Only)
PERFORMANCE
HYDRAULIC SYMBOL
Best stability is obtained with adjustment at
highest ow.
1
2
MECHANICAL FLOW CONTROLS
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526
mail: delta@delta-power.com • www.delta-power.com
WARNING: the specications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specic application should not be undertaken
without independent study, evaluation, and testing for suitability.
W 51 / 12-2022
0
1
2
0 500 20001000 1500 2500 3000
Pressure Drop (PSI)
0
5
0 50 100 150 200
Flow (GPM)
(bar)Pressure Drop (bar)Pressure Drop
Flow (LPM)
Port 2 to 1 Port 2 to 1
0
1
2
3
4
0 500 20001000 1500 2500 3000
Pressure Drop (PSI)
0
5
10
15
0 50
Flow (GPM)
100 150 200
Flow (LPM)
Port 2 to 1 Port 2 to 1
DIMENSIONS
ORDERING INFORMATION
Body Weight: .29 lbs (.13 kg)
MA-FCA – – –
OPTIONS BODIES
Buna Standard 00 Blank Without Body
Viton Standard V0 N 1/4” NPTF Ports
Buna, Knob 0K S #6 SAE Ports
Viton, Knob VK
FLOW
0.17 .08 - .17 GPM
00.5 .25 - .5 GPM
00.9 .5 - .9 GPM