IP-DAR-43-C Direct Acting Proportional, Pressure Reducing/Relieving, Slip-in type
DESCRIPTION
Special cavity, slip-in style flange retained, direct acting proportional, pressure reducing/relieving valve.
OPERATION
The IP-DAR-43-C generates a variable pressure in response to a PWM (Pulse Width Modulated) current
signal. With no current applied to the proportional solenoid, the inlet port 2 is blocked and the regulated
port 3 is vented to port 1.
As current is increased, fluid pressure is proportionally controlled at the regulated port 3. On attainment of
proportionally determined pressure at 3, the cartridge shifts to block flow at 2, thereby regulating
pressure at 3. In this mode, the valve also will relieve 3 to 1 at a variable value over the set reducing
pressure.
FEATURES
Slip-in style
Efficient wet-armature construction
Integral waterproof coil
Continuous duty rated solenoid
HYDRAULIC SYMBOL
Flanged retained product.
The coil is an integral part of the valve and is not
serviceable.
Tank Pressure level above zero is additive to the valves
expected reduced pressure value.
SNOITACIFICEPSEVLAVECNAMROFREP
Reduced pressure (bar) vs. current (mA)
(12 V and 24 Vcoil)
Nominal Flow 1 GPM (3,8 LPM) @ 8 bar Delta P
Max Inlet Pressure “H” version 5000 PSI (350 bar)
Max Inlet Pressure “L” version 700 PSI (50 bar)
Controlled pressure range 0÷25 bar / 0÷30 bar (see graph)
Reduced pressure tolerance + / 5%
Max. Back-pressure at T port 20 bar
Internal Leakage 15ml/min@ 500PSI (35 bar) inlet
35ml/min@ 5000PSI(350bar) inlet
Viscosity Range 36 to 3000 SSU (3 to 647 cSt)
)6044OSI(51/81OSInoitartliF
Media Operating Temp. Range
-25
C / +90 C
)gk52.(.sbl45.thgieW
Operating Fluid Media General Purpose Hydraulic Fluid
340TytivaC
T
Cavity Tool Kit K-T043
Flange mounting screws
M4x10 / torque 3ft-lbs (4 Nm)
COIL SPECIFICATIONS
Current Supply Characteristics
PWM (Pulse Width Modulation)
Rated Current Range
200÷1500 (12 V coil)
100÷750 (24 V coil)
PWM or Super-imposed Dither
Frequency
100 - 200 Hz
Coil Resistance (12 Vdc)
5.4 Ohm +/- 5% at 68
F(20 C)
Coil Resistance (24 Vdc) 22 Ohm +/- 5% at 68°F (20°C)
Max. Power consumption 12 Watt (20 C)
Protection Degree IP 67 according to IEC 529
Coil Termination Deutsch-Integral DT04-2P
Amp Junior Timer 84-9419
Color Connectors Black
PROPORTIONAL PRESSURE CONTROLS
Delta Power Company
4484 Boeing Drive - Rockford, IL 61109
WARNING: The specications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described
(herein). Any specic application should not be undertaken without independent study, evaluation, and testing for suitability.
Phone: (815) 397-6628 Fax: (815) 397-2526 E-mail: delta@delta-power.com
Page 528
PROPORTIONAL PRESSURE CONTROLS
DIMENSIONS
ORDERING INFORMATION
COIL
TERMINATION
AJ - Amp J. timer
DT - Deutsch DT04
IP - DAR - 43 - C – –
VOLTAGE
1 - 12 Vdc
2 - 24 Vdc
MAX. REGULATED
PRESSURE
1- 25 bar
2 - 30 bar
OPTIONS
00 - HNBR
standard
A0 - with ¿lter
NOTE: screen (on inlet port ): mesh 50 (300 ȝm)
INLET
PRESSURE
L
- up to 700 PSI
(50 bar)
H - up to 5000 PSI
(350 bar)
WARNING: The specications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described
(herein). Any specic application should not be undertaken without independent study, evaluation, and testing for suitability.
Phone: (815) 397-6628 Fax: (815) 397-2526 E-mail: delta@delta-power.com
Delta Power Company
4484 Boeing Drive - Rockford, IL 61109
Page 529