SPECIAL APPLICATION VALVES
Delta Power Company
4484 Boeing Drive - Rockford, IL 61109
WARNING: The specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described
(herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.
Phone: (815) 397-6628 Fax: (815) 397-2526 E-mail: delta@delta-power.com
IM-CVF-11 Inline Velocity Fuse
DESCRIPTION
3/8 NPTF thread, inline velocity fuse.
OPERATION
The IM-CVF-11 allows flow to pass between (1) and (2). When oil velocity from (1) to (2) exceeds the flow
setting, the valve shifts and blocks flow from (1) to (2).
FEATURES
HYDRAULIC SYMBOL
PERFORMANCE VALVE SPECIFICATIONS
Nominal Flow Max.
6 GPM (23 LPM)
Rated Operating Pressure 3500 PSI (241 bar)
Typical Internal Leakage
(150 SSU)
0 – 5 drops/min
Viscosity Range 36 to 3000 SSU (3 to 647 cSt)
Filtration ISO 18/16/13
Media Operating
Temperature Range
-40q to 250q F (-40q to 120q C)
Weight .18 lbs. (.08 kg)
Operating Fluid Media General Purpose Hydraulic Fluid
Page 622
SPECIAL APPLICATION VALVES
Delta Power Company
4484 Boeing Drive - Rockford, IL 61109
WARNING: The specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described
(herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.
Phone: (815) 397-6628 Fax: (815) 397-2526 E-mail: delta@delta-power.com
DIMENSIONS
ORDERING INFORMATION
IM-CVF - 11 -
FLOW SETTINGS
01.0 1 GPM
02.0 2 GPM
03.0 3 GPM
04.0 4 GPM
05.0 5 GPM
06.0 6 GPM
Page 623